Dej-txias Low Temperature Screw Chiller

Lus piav qhia luv luv:

Khoom taw qhia Cov khoom tseem ceeb xws li Semi-hermetic ntsia hlau compressor, roj separator, condenser, economizer, evaporator thiab tswj qhov system.Yog tias koj xav tau kev txhim khu kev ntseeg siab txias txias rau koj daim ntawv thov kev lag luam, peb muaj cov khoom koj xav tau.Peb scroll chillers yog tam sim no siv thoob ntiaj teb los lav ntau yam txheej txheem rau ntau lub tuam txhab ua lag luam.Peb tuaj yeem tsim cov kev cai chilling kev daws teeb meem raws li koj qhov kev xav tau txias txias thiab nrhiav txoj hauv kev ntxiv tus nqi rau yo ...


Product Detail

Khoom parameters

ntim thiab thauj

daim ntawv pov thawj

ua faq

Tsim tawmct kojroduction

Cov khoom tseem ceeb suav nrog Semi-hermetic ntsia hlau compressor, roj separator, condenser, economizer, evaporator thiab tswj qhov system.

Yog tias koj muaj kev xav tau kev txhim khu kev ntseeg siab txias txias rau koj daim ntawv thov kev lag luam, peb muaj cov khoom koj xav tau.Peb scroll chillers yog tam sim no siv thoob ntiaj teb los lav ntau yam txheej txheem rau ntau lub tuam txhab ua lag luam.Peb tuaj yeem tsim cov kev cai chilling kev daws teeb meem raws li koj qhov kev xav tau cua txias tshwj xeeb thiab nrhiav txoj hauv kev los ntxiv tus nqi rau koj cov txheej txheem nrog peb cov kev txhim khu kev qha thiab ua haujlwm kub qis qis.

HERO-TECH cov khoom tsim los pab txo kev cuam tshuam ib puag ncig nrog rau tiam tom ntej, tsis tshua muaj Ntiaj Teb Tsov Rog Thoob Ntiaj Teb (GWP) tub yees thiab kev ua haujlwm siab.

 

Tsimfeatures

-Coolant kub li ntawm 5ºC txog -40ºC.
-High npaum semi-hermetic ntxaib-ntsia hlau compressor saws, siab COP ruaj khov kev ua tau zoo thiab kev pab lub neej ntev.
-Compressor stepped peev xwm tswj, txo qhov pib tam sim no thiab cuam tshuam rau daim phiaj.

- 4 qib tswj muaj peev xwm, 25% -50% -75% -100%.
-25% -100% tsis tu ncua muaj peev xwm tswj, xyuas kom compressor tag nrho kev ua tau zoo, txuag nqi khiav rau cov neeg siv khoom.
-High raug kov npo thiab import PLC maub los tau txais.
'Multi-tiv thaiv muaj nuj nqi: compressor tawm tshaj qhov kub, lub cev muaj zog tshaj qhov kub, tiv thaiv khov, dhau tam sim no, theem ua ntu zus, siab / qis, ntws hloov.
"PLC khaws cia ntau, tso cai rau kev khaws cia tas mus li ntawm ntau dua 100 cov ntaub ntawv tsis raug, saib xyuas lub xeev ua haujlwm.
'Hloov lo lus teeb tsa, zam lub tsev los ntawm kev kaw lossis puas tsuaj los ntawm qhov xwm txheej.
"Control Cheebtsam suav nrog thermal expansion valve, solenoid valve, check valve yog muab los ntawm thoob ntiaj teb hom, kom ruaj khov thiab ua haujlwm zoo nyob rau hauv ntau yam kev ua haujlwm.
-Units raug kuaj tag nrho thiab ua haujlwm ntawm kev thauj khoom tag nrho, tawm hauv lub Hoobkas nrog cov tub yees, tuaj yeem pib thaum dej thiab fais fab txuas.
-Compressor nrog built-in tso lub lauj kaub silencer kom tsis muaj suab nrov khiav.
-Corrosion-resistance dej system raws li kev thov.

- Kev xaiv tub yees: R22, R407C, R404A.

 HTS-W

Daim ntawv thov

HTSL series tsis tshua muaj kub ntsia hlau chiller yog dav siv hauv kev tsim khoom hauv kev lag luam xws li

non-ferrous smelting / tshuaj / tshuaj / roj av chemistry / grain thiab roj / zaub mov thiab dej haus / mechanical / hluav taws xob / cua sib cais

Kev ua zaub mov

Txhawm rau kom ntseeg tau tias muaj kev nyab xeeb thiab zoo ib yam ntawm cov khoom noj khov, cov tuam txhab ua zaub mov xav tau cov cua txias qis rau hnub thiab hnub tawm.Peb cov ntsia hlau chillers kub qis tau muab tso rau hauv kev sim ntau yam kev siv khoom noj, suav nrog:

  • Ceev nrooj khov ntawm cov zaub mov npaj thiab zaub mov
  • Khaws cov khoom xyaw ua ntej siv
  • Ua ib feem ntawm kev tua kab mob thiab tshuaj tua kab mob

Kev kho mob

Qee cov txheej txheem kho mob fabrication thiab khaws cia yuav tsum tau ua kom txias kom ntseeg tau tias muaj kev nyab xeeb thiab ua haujlwm tau zoo.Thaum txias tsis ua hauj lwm tsis yog ib qho kev xaiv, koj xav tau ib tug low-temperature scroll chiller koj tuaj yeem suav rau:

  • Hloov ntau yam khoom siv kho mob thiab cov khoom sib txuas
  • Kev tsim cov tshuaj rhiab heev
  • Khaws cov tshuaj thiab tib neeg cov ntaub so ntswg rau kev phais
  • Kev ntsuam xyuas cov tshuaj tshiab thiab cov txheej txheem hauv cov xwm txheej txias heev

Cov khoom thiab cov khoom kuaj

Ntau hom khaub ncaws, cov khoom siv thiab cov khoom siv yuav tsum tau ntsuas qhov kub ntawm -35 ° C.Peb cov khoom siv hluav taws xob qis qis tuaj yeem siv rau ntau yam kev sim, xws li:

  • Automotive thiab thauj khoom pov thawj
  • Npuag thiab ntaub txias kub kuj thiab tiv thaiv
  • Yas, roj hmab thiab hlau lub zog ntawm qhov txias txias
  • Qhov kub thiab txias ua haujlwm ntawm coolants, roj thiab kua

 

 

Dependable, ntau yam, high-efficiency txias.

HERO-TECH chillers xa tus nqi rau ntau yam kev siv nrog kev siv zog ua kom zoo dua qub.

 

 

Kev pabcuam

-Processional Team: Engineering pab pawg nrog nruab nrab 15 xyoo ntawm kev paub nyob rau hauv industrial tub yees, pab neeg muag khoom nrog nruab nrab 7 xyoo ntawm kev paub, pab pawg neeg nrog nruab nrab 10 xyoo ntawm kev paub.

-Txoj kev daws teeb meem ib txwm muab raws li qhov xav tau.

-3 kauj ruam kev tswj hwm zoo: kev tswj xyuas zoo, kev tswj xyuas zoo, kev tswj xyuas zoo.

-12 lub hlis lav rau tag nrho cov khoom.Tsis pub dhau lub warranty, txhua qhov teeb meem tshwm sim los ntawm qhov tsis xws ntawm chiller nws tus kheej, kev pabcuam muaj txog qhov teeb meem daws tau.

 

Kev Tiv Thaiv Kev Nyab Xeeb

- Compressor tiv thaiv sab hauv,

- dhau kev tiv thaiv tam sim no,

- Kev tiv thaiv siab / qis,

- tiv thaiv kub dhau,

- High tso tawm kub tswb

- flow rate tiv thaiv,

-phase sequence/phase tsis muaj kev tiv thaiv,

- low-level coolant tiv thaiv,

-Anti khov tiv thaiv,

- Exhaust overheat tiv thaiv

 

Tsib qhov zoo ntawm HERO-TECH

•Hom lub zog : Peb yog cov kws tshaj lij thiab cov khoom lag luam sab saum toj ntawm cov tshuab chiller nrog 20 xyoo ntawm kev paub.

• Kev cob qhia kev cob qhia: Cov kws tshaj lij thiab cov kws tshaj lij & pab pawg muag khoom pabcuam rau kev lag luam txawv teb chaws, muab cov kev daws teeb meem raws li kev xav tau.

• Kev xa khoom sai: 1/2hp txog 50hp cua txias chillers hauv Tshuag rau kev xa khoom tam sim.

• Cov neeg ua haujlwm ruaj khov : Cov neeg ua haujlwm ruaj khov tuaj yeem ua kom ruaj khov thiab ua haujlwm zoo.Txhawm rau kom muaj kev pabcuam zoo thiab muaj txiaj ntsig zoo tom qab muag.

•Golden kev pabcuam : Kev pabcuam hu xovtooj hauv 1 teev, kev daws teebmeem hauv 4hrs, thiab muaj pab pawg ua haujlwm txawv tebchaw thiab tu.

 

Tsis yog txhua tus chillers raug tsim sib npaug.Rau kev ua kom txias thiab ua haujlwm ntev ntev, koj tuaj yeem nyob ntawmHERO-TECHntawm cov khoom cua txias rau tag nrho koj cov kev xav tau cua txias.

HERO-TECH ib txwm nthuav qhia tsim nyog, zoo tshaj plaws thiab kev daws teeb meem raws li kev pabcuam.

 

 


  • Yav dhau los:
  • Tom ntej:

  • Ib leeg compressor

    HTSL-40W ~ 85W

    Qauv (HTSL-***)

    40 W

    50 W

    60 W

    75w ua

    85w ua

    Nominal txias muaj peev xwm

    -10 ℃

    kw

    81.9 ua

    106.5 ib

    117.8 ib

    159

    183.4 ib

    -20 ℃

    55.9 ua

    72.7 ib

    80.3 ua

    108.5 ib

    125.1 ib

    -30 ℃

    35.7 ib

    46.4 ib

    51.3 ib

    69.3 ib

    80.0 ua

    Lub zog nkag

    kw

    33

    42

    47

    62

    70

    Lub zog

    3PH 380V ~ 415V 50HZ / 60HZ

    Cov tub yees Hom

    R22/R404A

    Them nqi

    kg

    28

    35

    42

    52.5 ib

    59.5 ib

    Tswj

    Thermostatic expansion valve

    Compressor Hom

    Semi-hermetic ntsia hlau

    Lub cev muaj zog

    kw

    33

    42

    47

    62

    70

    Pib hom

    Y-△

    Tswj peev xwm

    %

    0-25-50-75-100 ib

    Evaporator Hom

    Plhaub thiab raj (ss phaj kub exchanger)

    Chilled dej ntim

    -10 ℃

    m³/h

    12.4

    16.1

    17.5 Nws

    21.3

    27.7 ib

    -20 ℃

    8.3

    10.8

    11.9 ib

    14.4 ib

    18.6 ib

    -30 ℃

    5.1

    7.1

    8.4

    10.3

    13.4

    Dej siab poob

    kPa ua

    32

    35

    38

    42

    45

    Cov yeeb nkab txuas

    nti

    3

    3

    3

    3

    4

    Condenser Hom

    Plhaub thiab lub raj

    Cov dej txias txias

    m³/h

    25

    32.3

    35.5 ib

    43.3 ib

    60

    Dej siab poob

    kPa ua

    42

    42

    45

    43

    45

    Cov yeeb nkab txuas

    m³/h

    3

    3

    3

    3

    3

    Cov khoom siv kev nyab xeeb

    compressor sab hauv kev tiv thaiv, dhau kev tiv thaiv tam sim no, kev tiv thaiv siab / tsis tshua muaj siab, tiv thaiv qhov kub thiab txias, tiv thaiv tus nqi ntws, theem sib lawv liag / theem tsis muaj kev tiv thaiv, qib qis coolant tiv thaiv, tiv thaiv kev tiv thaiv khov, tiv thaiv cua sov

    Dimension Ntev

    mm

    2500

    2550

    2600

    2750 ib

    2800

    Dav

    mm

    780 ua

    780 ua

    780 ua

    780 ua

    950 ua

    Qhov siab

    mm

    1650

    1650

    1650

    1650

    Xyoo 1950

    Net nyhav

    kg

    9 20

    1100

    1250

    1600

    Xyoo 1900

    Khiav hnyav

    kg

    1050

    1250

    1400

    1780

    2100

    Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no
    1.Condensing kub 35 ℃
    2.Volume feem ntawm glycol dej tov 47.8%
    Peb muaj txoj cai los hloov cov kev qhia tshwj xeeb yam tsis muaj kev ceeb toom ntxiv

     

    HTSL-100W ~ 270W

     

    Qauv (HTSL-***)

    100 W

    120 W

    150 W

    180 W

    200 W

    240 W

    270 W

    Nominal txias muaj peev xwm

    -10 ℃

    kw

    212.2 ib

    252.3 ib

    316.7 ib

    390.6 ib

    453.9 ib

    5 35.5

    597.7 ib

    -20 ℃

    144.7 ib

    172.1 ib

    216.0 Nws

    266.5 ib

    309.6 ib

    3 65.3

    407.7 ib

    -30 ℃

    92.5 ib

    110.0 Nws

    138.1 ib

    170.3 ib

    197.9 ib

    233.5 Nws

    260.6 ib

    Lub zog nkag

    kw

    80

    97

    121

    148

    170

    202

    222

    Lub zog

    3PH 380V ~ 415V 50HZ / 60HZ

    Cov tub yees Hom

    R22/R404A

    Them nqi

    kg

    70

    84

    105

    126

    140

    168

    189

    Tswj

    Thermostatic expansion valve

    Compressor Hom

    Semi-hermetic ntsia hlau

    Lub cev muaj zog

    kw

    84

    97

    121

    148

    170

    202

    222

    Pib hom

    Y-△

    Tswj peev xwm

    %

    0-25-50-75-100 ib

    Evaporator Hom

    Plhaub thiab raj (ss phaj kub exchanger)

    Chilled dej ntim

    -10 ℃

    m³/h

    32

    38.2 ib

    48

    59

    68.8 ib

    80.6 ib

    90.8 ua

    -20 ℃

    21.5 ib

    25.6 ib

    32.3

    39.7 ib

    46.4 ib

    54.3 ib

    61.2 ib

    -30 ℃

    15.5 ib

    18.4 ib

    23.2

    28.7 ib

    33.4 ib

    39

    44

    Dej siab poob

    kPa ua

    40

    43

    45

    45

    45

    47

    47

    Cov yeeb nkab txuas

    nti

    4

    4

    5

    6

    6

    6

    6

    Condenser Hom

    Plhaub thiab lub raj

    Cov dej txias txias

    m³/h

    65

    77

    96.8 ua

    119.2 ib

    138.8 ib

    162.8 ib

    183.5 ib

    Dej siab poob

    kPa ua

    48

    46

    48

    48

    48

    48

    48

    Cov yeeb nkab txuas

    m³/h

    4

    4

    3 * 2

    3 * 2

    4 * 2

    4 * 2

    4 * 2

    Cov khoom siv kev nyab xeeb

    compressor sab hauv kev tiv thaiv, dhau kev tiv thaiv tam sim no, kev tiv thaiv siab / tsis tshua muaj siab, tiv thaiv qhov kub thiab txias, tiv thaiv tus nqi ntws, theem sib lawv liag / theem tsis muaj kev tiv thaiv, qib qis coolant tiv thaiv, tiv thaiv kev tiv thaiv khov, tiv thaiv cua sov

    Dimension Ntev

    mm

    2900 ib

    3000

    3300 ib

    3800 ib

    3900 ib

    4300 ib

    4500

    Dav

    mm

    950 ua

    1200

    1380

    1380

    1380

    1480

    1480

    Qhov siab

    mm

    Xyoo 1950

    1580

    1630

    1750

    1750

    1780

    1780

    Net nyhav

    kg

    2100

    2550

    2750 ib

    3 250

    3 450

    ib 3950

    ib 4260

    Khiav hnyav

    kg

    2300

    2750 ib

    3000

    3500

    3750 ib

    4 250

    ib 4560

    Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no
    1.Condensing kub 35 ℃
    2.Volume feem ntawm glycol dej tov 47.8%
    Peb muaj txoj cai los hloov cov kev qhia tshwj xeeb yam tsis muaj kev ceeb toom ntxiv

     

    Ob chav compressors:

     

    HTSL-100WD ~ 300WD

    Qauv (HTSL-***)

    100 WD

    120 WD

    150 WD

    170 wb

    200 WD

    240 wb

    280 wb

    300 WD

    Nominal txias muaj peev xwm

    -10 ℃

    kw

    213

    235.6 ib

    318.0 Nws

    366.8 ib

    424.4 ib

    504.6 ib

    599.8 ib

    ib 633.4

    -20 ℃

    145.4 ib

    160.6 ib

    217.0 Nws

    250.2 ib

    289.4 ib

    344.2 ib

    409.2 ib

    432.0 Nws

    -30 ℃

    92.8 ua

    102.6 ib

    138.6 ib

    160.0 Nws

    185.0 Nws

    220.0 Nws

    261.6 ib

    276.2 ib

    Lub zog nkag

    kw

    84

    94

    124

    140

    160

    194

    230

    242

    Lub zog

    3PH 380V ~ 415V 50HZ / 60HZ

    Cov tub yees Hom

    R22/R404A

    Them nqi

    kg

    35 * 2

    42 * 2

    52.5 * 2

    59.5 * 2

    70 * 2

    84 * 2

    98 * 2

    105 * 2

    Tswj

    Thermostatic expansion valve

    Compressor Hom

    Semi-hermetic ntsia hlau

    Lub cev muaj zog

    kw

    42 * 2

    47 * 2

    62 * 2

    70 * 2

    84 * 2

    97 * 2

    115 * 2

    121 * 2

    Pib hom

    Y-△

    Tswj peev xwm

    %

    0-25-50-75-100 ib

    Evaporator Hom

    Plhaub thiab raj (ss phaj kub exchanger)

    Chilled dej ntim -10 ℃

    m³/h

    32.2 ib

    35

    42.6 ib

    55.4 ib

    64

    76.4 ib

    90.8 ua

    96

    -20 ℃

    21.6 ib

    23.8 ib

    28.8 ib

    37.2 ib

    43

    51.2 ib

    61.2 ib

    64.6 ib

    -30 ℃

    14.2

    16.8 ib

    20.6

    26.8 ib

    31

    36.8 ib

    44

    46.4 ib

    Dej siab poob

    kPa ua

    42

    42

    46

    43

    45

    45

    43

    48

    Cov yeeb nkab txuas

    nti

    4

    4

    5

    6

    6

    6

    8

    8

    Condenser Hom

    Plhaub thiab lub raj

    Cov dej txias txias

    m³/h

    64.7 ib

    71

    86.6 ib

    120

    130

    154

    183.4 ib

    193.6 ib

    Dej siab poob

    kPa ua

    41

    42

    42

    45

    48

    46

    48

    48

    Cov yeeb nkab txuas

    m³/h

    4

    4

    3 * 2

    3 * 2

    4 * 2

    4 * 2

    4 * 2

    5 * 2

    Cov khoom siv kev nyab xeeb

    compressor sab hauv kev tiv thaiv, dhau kev tiv thaiv tam sim no, kev tiv thaiv siab / tsis tshua muaj siab, tiv thaiv qhov kub thiab txias, tiv thaiv tus nqi ntws, theem sib lawv liag / theem tsis muaj kev tiv thaiv, qib qis coolant tiv thaiv, tiv thaiv kev tiv thaiv khov, tiv thaiv cua sov

    Dimension Ntev

    mm

    2800

    2950 ib

    3 150

    ib 3480

    ib 3480

    3 650

    3 650

    3750 ib

    Dav

    mm

    780 ua

    810

    850

    875 ib

    895 ib

    1120

    1300

    1380

    Qhov siab

    mm

    1650

    1650

    1750

    1850

    1850

    Xyoo 1950

    Xyoo 1950

    2100

    Net nyhav

    kg

    Xyoo 1950

    2300

    2650

    2900 ib

    3 550

    4 050

    4 200

    4 550

    Khiav hnyav

    kg

    2250

    2500

    2950 ib

    3300 ib

    ib 3950

    4 450

    4600 ib

    5 050

    Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no
    1.Condensing kub 35ºC
    2.Volume feem ntawm glycol dej tov 47.8%
    Peb muaj txoj cai los hloov cov kev qhia tshwj xeeb yam tsis muaj kev ceeb toom ntxiv.

     

    HTSL-360WD ~ 540WD

    Qauv (HTSL-***)

    360 wb

    400 wb

    460 wb

    480 wb

    540 wb

    Nominal txias muaj peev xwm

    -10 ℃

    kw

    781.2 ib

    907.8 ib

    997.0 ib

    1071 ib

    1 195.4

    -20 ℃

    533.0 ua

    619.2 ib

    680.0 ib

    730.6 ib

    815.4 ib

    -30 ℃

    340.6 ib

    395.8 ib

    434.6 ib

    467.0 ib

    521.2 ib

    Lub zog nkag

    kw

    296 ib

    340

    380

    404

    444 ib

    Lub zog

    3PH 380V ~ 415V 50HZ / 60HZ

    Cov tub yees Hom

    R22/R404A

    Them nqi

    kg

    126 * 2

    140 * 2

    161 * 2

    168 * 2

    189 * 2

    Tswj

    Thermostatic expansion valve

    Compressor Hom

    Semi-hermetic ntsia hlau

    Lub cev muaj zog

    kw

    148 * 2

    170 * 2

    190 * 2

    202 * 2

    222 * 2

    Pib hom

    Y-△

    Tswj peev xwm

    %

    0-25-50-75-100 ib

    Evaporator Hom

    Plhaub thiab raj (ss phaj kub exchanger)

    Chilled dej ntim

    -10 ℃

    m³/h

    118

    137.6 ib

    151

    161.2 ib

    181.6 ib

    -20 ℃

    79.4 ib

    92.8 ua

    101.8 ib

    108.6 ib

    122.4 ib

    -30 ℃

    57.4 ib

    66.8 ib

    73.2 ib

    78

    88

    Dej siab poob

    kPa ua

    44

    45

    42

    45

    46

    Cov yeeb nkab txuas

    nti

    8

    8

    10

    10

    10

    Condenser Hom

    Plhaub thiab lub raj

    Cov dej txias txias

    m³/h

    238.4 ib

    277.6 ib

    305

    232.6 ib

    367 ib

    Dej siab poob

    kPa ua

    46

    42

    48

    48

    48

    Cov yeeb nkab txuas

    m³/h

    5 * 2

    5 * 2

    5 * 2

    6 * 2

    6 * 2

    Cov khoom siv kev nyab xeeb

    compressor sab hauv kev tiv thaiv, dhau kev tiv thaiv tam sim no, kev tiv thaiv siab / tsis tshua muaj siab, tiv thaiv qhov kub thiab txias, tiv thaiv tus nqi ntws, theem sib lawv liag / theem tsis muaj kev tiv thaiv, qib qis coolant tiv thaiv, tiv thaiv kev tiv thaiv khov, tiv thaiv cua sov

    Dimension Ntev

    mm

    4230 ib

    4230 ib

    4 350

    4 350

    4420 ib

    Dav

    mm

    1380

    1480

    1450

    1560

    1650

    Qhov siab

    mm

    2150

    2250

    2250

    2300

    2450

    Net nyhav

    kg

    5 100

    5 350

    5600 ib

    5850 ua

    6 100

    Khiav hnyav

    kg

    5600 ib

    ib 5950

    6300 ib

    6 450

    6700 ib

    Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no
    1.Condensing kub 35ºC
    2.Volume feem ntawm glycol dej tov 47.8%
    Peb muaj txoj cai los hloov cov kev qhia tshwj xeeb yam tsis muaj kev ceeb toom ntxiv.

     

     

    Packing shipping

    daim ntawv pov thawj

    Q1: Koj puas tuaj yeem pab peb kom pom zoo tus qauv rau peb qhov project?
    A1: Yog lawm, peb muaj engineer los xyuas cov ntsiab lus thiab xaiv tus qauv raug rau koj.Raws li cov hauv qab no:
    1) Lub peev xwm txias;
    2) Yog tias koj tsis paub, koj tuaj yeem muab tus nqi ntws rau koj lub tshuab, qhov kub thiab txias tawm ntawm koj qhov siv;
    3) Ib puag ncig kub;
    4) Hom tub yees, R22, R407c lossis lwm yam, pls qhia meej;
    5) Voltage;
    6) Daim ntawv thov kev lag luam;
    7) Cov twj tso kua mis ntws thiab siab xav tau;
    8) Lwm yam kev cai tshwj xeeb.

     

     

    Q2: Yuav ua li cas kom ntseeg tau koj cov khoom zoo?
    A2: Tag nrho peb cov khoom nrog daim ntawv pov thawj CE thiab peb lub tuam txhab nruj me ntsis ua raws li ISO900 kev tswj xyuas zoo.Peb siv cov khoom lag luam nto moo thoob ntiaj teb, xws li DANFOSS, COPELAND, SANYO, BITZER, HANBELL compressors, Schneider hluav taws xob Cheebtsam, DANFOSS / EMERSON cov tub yees.
    Cov chav nyob yuav raug kuaj tag nrho ua ntej pob thiab Cov pob yuav raug kuaj xyuas kom zoo.

     

     

    Q3: Lub warranty yog dab tsi?
    A3: 1 xyoo lav rau txhua qhov chaw;Tag nrho lub neej ua haujlwm dawb!

     

     

    Q4: Koj puas yog cov chaw tsim khoom?
    A4: Yog lawm, peb muaj ntau tshaj 23 xyoos hauv kev lag luam tub yees.Peb lub Hoobkas nyob hauv Shenzhen;Txais tos tuaj xyuas peb txhua lub sijhawm.Kuj tseem muaj patent ntawm cov chillers tsim.

     

     

    Q5: Kuv tuaj yeem tso qhov kev txiav txim li cas?
    A5: Send us enquiry via email: sales@szhero-tech.com, call us via Cel number +86 15920056387 directly.

    QHOV CHAW UA HAUJ LWM