Hauv laser system.Laser qhov chaw thiab beam maub los yuav tsum tau txias.Cov dej txias yog ib txwm xav tau hauv qhov kub ntawm 15 ℃ txog 22 ℃, nrog ± 1 ℃ lossis 2 ℃ raug thiab qee zaum hauv ± 0.1 ℃.Laser muaj tshwj xeeb yuav tsum tau rau conductivity thiab corrosiveness ntawm cov dej txias, ib txwm dej voj yuav tsum stainless hlau cov ntaub ntawv.
Daim ntawv thov
Laser chiller feem ntau yog siv rau laser marker, laser engraving tshuab, laser welder, laser txiav tshuab, laser txhaj tshuab, thiab lwm yam, rau kev tuav tswj qhov kub ntawm cov khoom siv laser, yog li kom ua haujlwm zoo.
Dependable, ntau yam, high-efficiency txias.
HERO-TECH chillers xa tus nqi rau ntau yam kev siv nrog kev siv zog ua kom zoo dua qub.
Tsim nta
- Loj ntim ss cia tank thiab SS coil evaporator.
- Ua-nyob rau hauv siab siab stainless hlau chilled dej twj tso kua mis.xyuas kom dej zoo thiab siab.
-Precision filtering ntaus ntawv tuaj yeem muab tau raws li qhov kev thov, suav nrog cov teeb meem pom thiab deionizer kom ntseeg tau cov dej txias zoo, txuas ntxiv laser thiab chiller lub neej kev pab cuam.
-Multi-tiv thaiv cov cuab yeej: Flow switch, water pressure switch, acoustic and optical alarm system.
-Kev tiv thaiv teeb liab tso zis: Dej ntws lub tswb ceeb toom tso tawm, dej theem tswb teeb liab tso zis, kub tiv thaiv lub tswb teeb liab tso zis, ua kom lub laser thiab chiller khiav zoo.
- Tshem tawm sab panels kom yooj yim nkag
-Cov txheej txheem Circuit Court nrog thermal rwb thaiv tsev
-Sight iav nrog qib qis hloov
-Swivel log rau qhov chaw yooj yim
-Refrigerant Circuit Court nrog sab saum toj hom hermetic scroll compressor Tswj vaj huam sib luag
-Ua kom tiav nrog cov khoom siv tswj kev cuam tshuam nrog cov microprocessor
-Control rau qhov kub thiab txias thiab ceeb toom kev nyab xeeb
-Schneider hom hluav taws xob Cheebtsam xyuas kom lub chiller chav ua haujlwm ruaj khov nrog lub sijhawm ua haujlwm ntev.
-Compact tsim, yooj yim rau nruab thiab khiav lag luam, yooj yim los ntxuav thiab tu.
Kev pabcuam
-Processional Team: Engineering pab pawg nrog nruab nrab 15 xyoo ntawm kev paub nyob rau hauv industrial tub yees, pab neeg muag khoom nrog nruab nrab 7 xyoo ntawm kev paub, pab pawg neeg nrog nruab nrab 10 xyoo ntawm kev paub.
-Txoj kev daws teeb meem ib txwm muab raws li qhov xav tau.
-3 kauj ruam kev tswj hwm zoo: kev tswj xyuas zoo, kev tswj xyuas zoo, kev tswj xyuas zoo.
-12 lub hlis lav rau tag nrho cov khoom.Tsis pub dhau lub warranty, txhua qhov teeb meem tshwm sim los ntawm qhov tsis xws ntawm chiller nws tus kheej, kev pabcuam muaj txog qhov teeb meem daws tau.
Kev Tiv Thaiv Kev Nyab Xeeb
- Compressor tiv thaiv sab hauv,
- dhau kev tiv thaiv tam sim no,
- Kev tiv thaiv siab / qis,
- tiv thaiv kub dhau,
- High tso tawm kub tswb
- flow rate tiv thaiv,
-phase sequence/phase tsis muaj kev tiv thaiv,
- low-level coolant tiv thaiv,
-Anti khov tiv thaiv,
- Exhaust overheat tiv thaiv
Tsib qhov zoo ntawm HERO-TECH
•Hom lub zog : Peb yog cov kws tshaj lij thiab cov khoom lag luam sab saum toj ntawm cov tshuab chiller nrog 20 xyoo ntawm kev paub.
• Kev cob qhia kev cob qhia: Cov kws tshaj lij thiab cov kws tshaj lij & pab pawg muag khoom pabcuam rau kev lag luam txawv teb chaws, muab cov kev daws teeb meem raws li kev xav tau.
• Kev xa khoom sai: 1/2hp txog 50hp cua txias chillers hauv Tshuag rau kev xa khoom tam sim.
• Cov neeg ua haujlwm ruaj khov : Cov neeg ua haujlwm ruaj khov tuaj yeem ua kom ruaj khov thiab ua haujlwm zoo.Txhawm rau kom muaj kev pabcuam zoo thiab muaj txiaj ntsig zoo tom qab muag.
•Golden kev pabcuam : Kev pabcuam hu xovtooj hauv 1 teev, kev daws teebmeem hauv 4hrs, thiab muaj pab pawg ua haujlwm txawv tebchaw thiab tu.
Tsis yog txhua tus chillers raug tsim sib npaug.Rau kev ua kom txias thiab ua haujlwm ntev ntev, koj tuaj yeem nyob ntawm HERO-TECH ntawm Cov Khoom Siv Txias rau txhua qhov koj xav tau txias.
Qauv (HTL-***) | 1/2 A | 1A | 1.5 A | 2A | 3A | 5A | 6A | 8A | 10 AD | 12 AD | 15 AD | 20 AD | ||
Nominal txias muaj peev xwm | Kcal / h | 1419 ib | 2385 ib | ib 3264 | 4592 ib | ib 7654 | 11508 ib | ib 14310 | 18816 ib | 23 013 | 28620 ib | 36756 ib | ib 46629 | |
kw | 1.65 ib | 2.75 ib | 3.79 ib | 5.34 ib | 8.9 ib | 13.38 Nws | 16.64 Nws | 21.88 Nws | 26.76 Nws | 33.28 Nws | 42.74 ib | 54.22 ib | ||
Input zog | kw | 0.895 ib | 1.4 | 2.07 Nws | 2.24 | 3.15 | 4.71 ib | 5.42 ib | 7.15 Nws | 9.76 ib | 11.02 Nws | 15.3 | 18.6 ib | |
Lub zog | 1 PH 220V 50HZ | 3PH 380V ~ 415V 50HZ / 60HZ | ||||||||||||
Cov tub yees | Hom | R22 | ||||||||||||
Tswj | capillary | Thermostatic expansion valve | ||||||||||||
Compressor | Hom | Hermetic-rotary | Hermetic-scroll | |||||||||||
Lub cev muaj zog | kw | 0.45 ib | 0.89 ib | 1.52 ib | 1.73 ib | 2.5 | 3.68 ib | 4.31 ib | 2.95 * 2 | 3.68 * 2 | 4.31 * 2 | 5.95 * 2 | 7.4 * 2 | |
Condenser | Hom | Finned coil + tsis tshua muaj suab nrov axial kiv cua | ||||||||||||
Cua ntim | m³/h | 750 | 1000 | 1500 | 2000 | 3000 | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 | 20000 | |
Ntxuam zog | kw | 0.095 ib | 0.14 ib | 0.18 | 0.18 | 0.14 * 2 | 0.14 * 2 | 0.18 * 2 | 0.25 * 2 | 0.45 * 2 | 0.45 * 2 | 0.6 * 2 | 0.8 * 2 | |
Evaporator | Hom | Plhaub thiab raj (ss phaj kub exchanger) | ||||||||||||
Chilled dej ntim | m³/h | 0.258 ib | 0.476 ib | 0.59 ib | 0.908 ib | 1.36 ib | 2.22 | 2.6 | 3.52 ib | 4.44 ib | 5.03 ib | 7.1 | 8.84 ib | |
Tank ntim | litre | 16 | 16 | 20 | 20 | 50 | 60 | 110 | 120 | 200 | 200 | 270 | 350 | |
Cov yeeb nkab txuas | m³/h | 1/2 | 1/2 | 1/2 | 1/2 | 1 | 1 | 1 | 1-1/2 | 2 | 2 | 2 | 2-1/2 | |
Pump | Hwj chim | kw | 0.37 ib | 0.37 ib | 0.37 ib | 0.37 ib | 0.37 ib | 0.75 ib | 0.75 ib | 0.75 ib | 1.5 | 1.5 | 2.2 | 2.2 |
Nqa | m | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |
Flow hloov | Ua haujlwm ntws> 3.5L / min, tso tawm <1.4L / min | Ua haujlwm ntws> 16L / min, tso tawm <10L / min | ||||||||||||
Cov khoom siv kev nyab xeeb | Compressor sab hauv kev tiv thaiv, dhau kev tiv thaiv tam sim no, kev tiv thaiv siab / tsis tshua muaj siab, tiv thaiv qhov kub thiab txias, tiv thaiv tus nqi ntws, theem sib lawv liag / theem tsis muaj kev tiv thaiv, tsis tshua muaj cua txias tiv thaiv, tiv thaiv kev tiv thaiv khov, tiv thaiv cua sov | |||||||||||||
Dimension | Ntev | mm | 550 | 600 | 650 | 650 | 1030 | 1030 | 1170 ib | 1350 | 1550 | 1550 | Xyoo 1830 | 2010 |
Dav | mm | 350 | 400 | 520 | 520 | 560 | 560 | 610 | 680 | 760 ib | 760 ib | 850 | 950 ua | |
Qhov siab | mm | 755 ib | 885 ib | 1030 | 1030 | 1330 ib | 1330 ib | 1390 ib | 1520 | 1680 | 1680 | Xyoo 1870 | Xyoo 1990 | |
Net nyhav | kg | 45 | 52 | 75 | 85 | 132 | 165 | 183 | 265 | 345 | 382 ib | 580 | 650 | |
Nco tseg: Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no: |
Q1: Koj puas tuaj yeem pab peb kom pom zoo tus qauv rau peb qhov project?
A1: Yog lawm, peb muaj engineer los xyuas cov ntsiab lus thiab xaiv tus qauv raug rau koj.Raws li cov hauv qab no:
1) Lub peev xwm txias;
2) Yog tias koj tsis paub, koj tuaj yeem muab tus nqi ntws rau koj lub tshuab, qhov kub thiab txias tawm ntawm koj qhov siv;
3) Ib puag ncig kub;
4) Hom tub yees, R22, R407c lossis lwm yam, pls qhia meej;
5) Voltage;
6) Daim ntawv thov kev lag luam;
7) Cov twj tso kua mis ntws thiab siab xav tau;
8) Lwm yam kev cai tshwj xeeb.
Q2: Yuav ua li cas kom ntseeg tau koj cov khoom zoo?
A2: Tag nrho peb cov khoom nrog daim ntawv pov thawj CE thiab peb lub tuam txhab nruj me ntsis ua raws li ISO900 kev tswj xyuas zoo.Peb siv cov khoom lag luam nto moo thoob ntiaj teb, xws li DANFOSS, COPELAND, SANYO, BITZER, HANBELL compressors, Schneider hluav taws xob Cheebtsam, DANFOSS / EMERSON cov tub yees.
Cov chav nyob yuav raug kuaj tag nrho ua ntej pob thiab Cov pob yuav raug kuaj xyuas kom zoo.
Q3: Lub warranty yog dab tsi?
A3: 1 xyoo lav rau txhua qhov chaw;Tag nrho lub neej ua haujlwm dawb!
Q4: Koj puas yog cov chaw tsim khoom?
A4: Yog lawm, peb muaj ntau tshaj 23 xyoos hauv kev lag luam tub yees.Peb lub Hoobkas nyob hauv Shenzhen;Txais tos tuaj xyuas peb txhua lub sijhawm.Kuj tseem muaj patent ntawm cov chillers tsim.
Q5: Kuv tuaj yeem tso qhov kev txiav txim li cas?
A5: Send us enquiry via email: sales@szhero-tech.com, call us via Cel number +86 15920056387 directly.