Variable-speed Screw chiller

Lus piav qhia luv luv:

Cov yam ntxwv tseem ceeb l Dej kub yog 5C txog 20C.l DANFOSS inverter l Bitzer / Hanbell semi-hermetic ntsia hlau compressor.l Kev txuag hluav taws xob txog li 30% l Kub qhov tseeb upto +/-0.1C l Stepless muaj peev xwm tswj, l Plhaub thiab raj evaporator, high efficiency thiab cleanable l Plhaub thiab raj condenser nrog txaus tshav kub exchanger nto.l Lub tub yees solenoid valve, los tiv thaiv compressor thaum nres.l Refrigerant pom iav, txhawm rau saib xyuas cov xwm txheej tub yees ntxiv l Cov tub yees Tsawg thiab ...


Product Detail

Cov ntsiab lus Parameter

ntim thiab thauj

daim ntawv pov thawj

ua faq

Cov yam ntxwv tseem ceeb

l Dej kub ntawm 5C txog 20C.

l DANFOSS inverter

l Bitzer / Hanbell semi-hermetic ntsia hlau compressor.

l Kev txuag hluav taws xob txog li 30%

l Kub qhov tseeb txog +/-0.1C

l Stepless muaj peev xwm tswj,

l Plhaub thiab raj evaporator, ua haujlwm siab thiab huv

l Plhaub thiab raj condenser nrog txaus tshav kub txauv nto.

l Lub tub yees solenoid valve, los tiv thaiv compressor thaum nres.

l Refrigerant pom iav, txhawm rau saib xyuas cov tub yees ntxiv

l Refrigerant Low thiab High Pressure Gauges

l PLC tswj, saib xyuas tag nrho ntawm chav tsev khiav haujlwm.

l Axial ntxuam lub cev muaj zog, nrog ywj siab lub cev muaj zog txhawb nqa bracket.

l Cov khoom siv tiv thaiv ntau yam kom paub tseeb tias lub chiller thiab cov khoom siv khiav kev nyab xeeb.

l Schneider hluav taws xob Cheebtsam.

l Danfoss / Emerson thermal Cheebtsam.

 

Kev Tiv Thaiv Kev Nyab Xeeb

u Compressor tiv thaiv sab hauv

u Kev tiv thaiv tam sim no

u Kev tiv thaiv siab / qis

u High tso tawm kub tswb

u Kev tiv thaiv kub dhau

u Flow hloov

u Phase sequence/theem tsis muaj kev tiv thaiv

u Anti-freezing tiv thaiv

 

Main configuration for HTSV-A, HTSV-W

Yam khoom

Hom

Hom

Qhov chaw ntawm keeb kwm

Lub cev muaj zog

Compressor

Bitzer

Semi-hermetic ntsia hlau

Lub teb chaws Yelemees

Compressor rau kev xaiv

Hanbell

Semi-hermetic ntsia hlau

Taiwan, Suav

Thermal Cheebtsam

Siab ntsuas

Jever

Hom roj

Taiwan, Suav

Siab tswj

Fengsen

——

Taiwan, Suav

Expansion valve

Emerson

Thermal expansion valve

Teb chaws USA

Solenoid valve

FDF/Emerson

——

Tuam Tshoj/Teb chaws USA

Pom iav

Danfoss

——

Denmark

Qhuav lim

Emerson/ALCO

——

Teb chaws USA

Thaum tshav kub kub exchanger

Condenser

Hero-Tech

Plhaub thiab lub raj/

 Aluminium finned tooj liab tube

Tuam Tshoj

Evaporator

Hero-Tech

Plhaub thiab lub raj

Tuam Tshoj

Tswj

Inverter

DANFOSS

DEMARK

Tus tswj

PUNP

PLC

Taiwan

Kev ua haujlwm vaj huam sib luag

PUNP

LCD

Taiwan

Inverter

Danfoss

Denmark

AC contactor

LG

——

Kauslim

Nruab nrab relay

Omron

——

Nyiv

Thermal relay

LG

——

Kauslim

Cov kev teeb tsa saum toj no yog raws li tus qauv tsim.Txhua yam lus nug thov hu rau Hero-Tech.

 

 


  • Yav dhau los:
  • Tom ntej:

  • Cua txias ntsia hlau chiller nrog VFD--Inverter chiller

    Ib leeg ntsia hlau compressor

    Homl [HTSV-***]

    40 A

    50 A

    60 A

    65A

    75A

    85a ib

    Nominal txias muaj peev xwm@7C

    * 103kcal / h

    54.8-91.8 Nws

    71-118.5 Nws

    79.6 ~ 133.3 ib

    97-161.6 ib

    105.8 ~ 177

    125.5-209

    kw

    63.8–106.7

    82.6 ~ 137.8

    92.6-155

    112.8-188

    123-205.6

    146-243 : kuv

    Nominal txias muaj peev xwm@10C

    * 103kcal / h

    62-103.2

    80-133.3

    90-150 Nws

    110-182 : kuv

    119 ~ ib199

    141-236 : kuv

    kw

    72-120 : kuv

    93-155 : kuv

    104.4-174

    127.4-212

    139-231.3 ib

    164.3-274

    Nominal txias muaj peev xwm@12 C

    * 103kcal / h

    67.1–111.5

    86-143.6

    96-161.6

    117.8-197

    129-215 : kuv

    152.2-254

    kw

    78-129.6

    100-167 : kuv

    112-188 : kuv

    137-229 : kuv

    150-250

    177-295.6

    Max siv zog

    kw

    38.8 ib

    49.3

    55.1 ib

    64.2 ib

    72.2 ib

    81

    Hwj chimqhov chaw

    3PH 380V ~ 415V 50HZ (3PH 220V / 380V / 440V 60HZ)rau kev xaiv)

    Cov tub yees

    Hom

    r407 uaC

    Them nqi

    kg

    28

    35

    42

    45.5 ib

    52

    60

    Tswj

    Hluav taws xobexpansion valve

    Compressor

    Hom

    Semi-hermetic ntsia hlau

    Lub cev muaj zog

    kw

    22.6 ~ ib36.4

    28 ~ ib45.7

    31.6 ~ ib50.3

    38.2-59.4 Nws

    41.9-65.8 Nws

    46.7-74.6

    Pib hom

    Inverter

    Nyiaj ntau

    HZ

    30 ~ 50/60

    Evaporator

    Hom

    Plhaub thiab raj ( phaj kub exchanger)

    chilleddej ntim

    m3/h

    12 ~ ib18

    16 ~ ib23.6 ib

    18 ~ ib25.7 ib

    22-28 : kuv

    23.8-34.4 Nws

    28-40.5 Nws

    siab poob

    kPa

    32

    35

    38

    38

    42

    45

    Yeebkev sib txuas

    inch

    3

    3

    3

    3

    3

    3

    Condenser

    Hom

    high efficiency finned cooper raj+Loj ntim & tsis tshua muaj suab nrovaxialkiv cua

    Lub cev muaj zog

    kw

    2.4

    3.6

    4.8

    4.8

    6.4

    6.4

    Cua ntim

    m3/h

    40000

    50000

    60000

    70000

    80000

    90000

    Cov khoom siv kev nyab xeeb

    Compressor tiv thaiv sab hauv, overload relay, siab thiab qis hloov,anti-freezing, theem yuam kev tiv thaiv, tso pa roj cua kub, ntws hloov

    Dimension

    Ntev

    mm

    2 180

    2350

    2650

    2850

    3310

    ib 3630

    Dav

    mm

    1800

    1800

    1800

    1800

    1800

    1800

    Qhov siab

    mm

    2050

    2050

    2163 ib

    2163 ib

    2200

    2140

    Net nyhav

    kg

    1300

    1600

    Xyoo 1900

    2150

    2350

    2550

    Khiav hnyav

    kg

    1450

    1750

    2100

    2350

    2550

    2800

    Ib leeg ntsia hlau compressor

    Homl [HTSV-***]

    90A

    100A

    120A

    135A

    150 A

    Nominal txias muaj peev xwm

    * 103kcal / h

    149-249 ib

    163.4 ~ ib150

    193-321 : kuv

    228-380 : kuv

    241-444 ib

    kw

    173.7 ~ 289.5 ib

    189.9 ~ 316.5

    224-373.4 ib

    265.1–441.8

    280-466.5 Nws

    Max siv zog

    kw

    83.1 ib

    87.5 ib

    114.3 ib

    129

    141.5 ib

    Hwj chimqhov chaw

    3PH 380V ~ 415V 50HZ (3PH 220V / 380V / 440V 60HZ)rau kev xaiv)

    Cov tub yees

    Hom

    r407 uaC

    Them nqi

    kg

    63

    70

    84

    94.5 ua

    105

    Tswj

    Hluav taws xobexpansion valve

    Compressor

    Hom

    Semi-hermetic ntsia hlau

    Lub cev muaj zog

    kw

    49.1-76.7 Nws

    54.5–80.3

    65.3–103.5

    75.7–118.2

    79.9-126.7 Nws

    Pib hom

    Inverter

    Nyiaj ntau

    HZ

    30 ~ 50/60

    Evaporator

    Hom

    Plhaub thiab raj ( phaj kub exchanger)

    chilleddej ntim

    m3/h

    29-44 : kuv

    32-46.4 Nws

    35-55 : kuv

    45-62 : kuv

    48-69.5 Nws

    Dejsiab poob

    kPa

    43

    43

    41

    42

    41

    Yeebkev sib txuas

    inch

    3

    4

    4

    4

    5

    Condenser

    Hom

    high efficiency finned cooper raj+Loj ntim & tsis tshua muaj suab nrovaxialkiv cua

    Lub cev muaj zog

    kw

    6.4

    7.2

    10.8

    10.8

    10.8

    Cua ntim

    m3/h

    90000

    100000

    135000

    1350000

    1500000

    Cov khoom siv kev nyab xeeb

    Compressor tiv thaiv sab hauv, overload relay, siab thiab qis hloov,anti-freezing, theem yuam kev tiv thaiv, tso pa roj cua kub, ntws hloov

    Dimension

    Ntev

    mm

    ib 3630

    4 100

    5 030

    5480 ua

    5800 ib

    Dav

    mm

    1800

    2000

    2000

    2000

    2000

    Qhov siab

    mm

    2140

    2210

    2160

    2210

    2210

    Net nyhav

    kg

    2650

    2800

    2950 ib

    3100

    3200

    Khiav hnyav

    kg

    2900 ib

    3 050

    3250

    3400 ib

    3500

    Dual compressors

    Homl [HTSV-***]

    80 AD

    100 AD

    120 AD

    130 AD

    150 AD

    170 AD

    Nominal txias muaj peev xwm

    * 103kcal / h

    129-222 : kuv

    160-266.6

    180-299 : kuv

    219-364 : kuv

    239-399 ib

    283-471 : kuv

    kw

    144-259.2

    186-310 : kuv

    208.8-348

    254.8–423.6

    278-462.6 ib

    328.6 ~ 547.8

    Max siv zog

    kw

    79.2 ib

    98.6 ib

    112

    129.6 ib

    142.4 ib

    162

    Hwj chimqhov chaw

    3PH 380V ~ 415V 50HZ (3PH 220V / 380V / 440V 60HZ)rau kev xaiv)

    Cov tub yees

    Hom

    r407 uaC

    Them nqi

    kg

    28*2

    35*2

    42*2

    45.5 * 2

    52 * 2

    60 * 2

    Tswj

    Hluav taws xobexpansion valve

    Compressor

    Hom

    Semi-hermetic ntsia hlau

    Lub cev muaj zog

    kw

    45.2-72.8 Nws

    56-91.4 ib

    63.2-100.6

    76.4 ~ 118.8

    83.8 ~ 131.6

    93.4-149.2

    Pib hom

    Inverter

    Nyiaj ntau

    HZ

    30 ~ 50/60

    Evaporator

    Hom

    Plhaub thiab raj ( phaj kub exchanger)

    chilleddej ntim

    m3/h

    24-35.6 Nws

    32-46.8 Nws

    36-50.8 Nws

    44-56 : kuv

    47.6-68

    56-80 : kuv

    siab poob

    kPa

    45

    43

    43

    41

    41

    42

    Yeebkev sib txuas

    inch

    3

    4

    4

    5

    5

    6

    Condenser

    Hom

    high efficiency finned cooper raj+Loj ntim & tsis tshua muaj suab nrovaxialkiv cua

    Lub cev muaj zog

    kw

    6.4

    7.2

    10.8

    10.8

    10.8

    12.8 ib

    Cua ntim

    m3/h

    80000

    100000

    120000

    130000

    150000

    165000

    Cov khoom siv kev nyab xeeb

    Compressor tiv thaiv sab hauv, overload relay, siab thiab qis hloov,anti-freezing, theem yuam kev tiv thaiv, tso pa roj cua kub, ntws hloov

    Dimension

    Ntev

    mm

    ib 3630

    4 100

    5 030

    5480 ua

    5800 ib

    3630 * 2

    Dav

    mm

    1800

    2000

    2000

    2000

    2000

    1800

    Qhov siab

    mm

    2140

    2210

    2160

    2210

    2210

    2140

    Net nyhav

    kg

    2500

    2950 ib

    3 350

    3750 ib

    4 100

    4 350

    Khiav hnyav

    kg

    2800

    3 250

    3750 ib

    4 050

    4500

    ib 4850

    Ob tug modular

    Homl [HTSV-***]

    180AD

    200AD

    240AD

    270 AD

    300 AD

    Nominal txias muaj peev xwm

    * 103kcal / h

    299-498 Ib

    327-544 : kuv

    385-642 : kuv

    456-760 : kuv

    482-802 : kuv

    kw

    347.4-579 Ib

    379.8-633 Ib

    448-746.8 ib

    530-884 : kuv

    560-933 : kuv

    Max siv zog

    kw

    166.2 ib

    188.4 ib

    225

    254.4 ib

    279.2 ib

    Hwj chimqhov chaw

    3PH 380V ~ 415V 50HZ (3PH 220V / 380V / 440V 60HZ)rau kev xaiv)

    Cov tub yees

    Hom

    r407 uaC

    Them nqi

    kg

    63 * 2

    70 * 2

    84 * 2

    94.5 * 2

    105 * 2

    Tswj

    Hluav taws xobexpansion valve

    Compressor

    Hom

    Semi-hermetic ntsia hlau

    Lub cev muaj zog

    kw

    98.2-153.4

    109–172.4

    130.6-207

    151.4 ~ 236.4 ib

    159.8 ~ 253.4 ib

    Pib hom

    Inverter

    Nyiaj ntau

    HZ

    30 ~ 50/60

    Evaporator

    Hom

    Plhaub thiab raj ( phaj kub exchanger)

    chilleddej ntim

    m3/h

    58-88 : kuv

    64-92.8 ib

    70-110 : kuv

    90-124 : kuv

    96-139 : kuv

    Dejsiab poob

    kPa

    43

    43

    41

    42

    41

    Yeebkev sib txuas

    inch

    6

    6

    8

    8

    8

    Condenser

    Hom

    high efficiency finned cooper raj+Loj ntim & tsis tshua muaj suab nrovaxialkiv cua

    Lub cev muaj zog

    kw

    12.8 ib

    16

    18

    18

    25.6 ib

    Cua ntim

    m3/h

    180000

    200000

    260000

    2600000

    3000000

    Cov khoom siv kev nyab xeeb

    Compressor tiv thaiv sab hauv, overload relay, siab thiab qis hloov,anti-freezing, theem yuam kev tiv thaiv, tso pa roj cua kub, ntws hloov

    Dimension

    Ntev

    mm

    3630 * 2

    4100 * 2

    5030 * 2

    5480 * 2

    5800 * 2

    Dav

    mm

    1800

    2000

    2000

    2000

    2000

    Qhov siab

    mm

    2140

    2210

    2160

    2210

    2210

    Net nyhav

    kg

    4 550

    4 750

    5 200

    5500

    5700 ib

    Khiav hnyav

    kg

    5 050

    5 250

    5800 ib

    6000

    6300 ib

    Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no:

    1. Cov dej txias txias / rov qab kub 10 ° C / 15 ° C

    2. Condensing kub 45 ° C, evaporating kub 5 ° C

    3. Chiller yuav tsum tau siv nyob rau hauv max 40C ambient kub

    4. R22 rau kev xaiv, ib zaug ambient kub tshaj 45C, R134A yuav tsum tau siv.

    Peb muaj txoj cai los hloov cov kev qhia tshwj xeeb yam tsis muaj kev ceeb toom ntxiv.

     

    Packing shipping

    daim ntawv pov thawj

    Q1: Koj puas tuaj yeem pab peb kom pom zoo tus qauv rau peb qhov project?
    A1: Yog lawm, peb muaj engineer los xyuas cov ntsiab lus thiab xaiv tus qauv raug rau koj.Raws li cov hauv qab no:
    1) Lub peev xwm txias;
    2) Yog tias koj tsis paub, koj tuaj yeem muab tus nqi ntws rau koj lub tshuab, qhov kub thiab txias tawm ntawm koj qhov siv;
    3) Ib puag ncig kub;
    4) Hom tub yees, R22, R407c lossis lwm yam, pls qhia meej;
    5) Voltage;
    6) Daim ntawv thov kev lag luam;
    7) Cov twj tso kua mis ntws thiab siab xav tau;
    8) Lwm yam kev cai tshwj xeeb.

     

     

    Q2: Yuav ua li cas kom ntseeg tau koj cov khoom zoo?
    A2: Tag nrho peb cov khoom nrog daim ntawv pov thawj CE thiab peb lub tuam txhab nruj me ntsis ua raws li ISO900 kev tswj xyuas zoo.Peb siv cov khoom lag luam nto moo thoob ntiaj teb, xws li DANFOSS, COPELAND, SANYO, BITZER, HANBELL compressors, Schneider hluav taws xob Cheebtsam, DANFOSS / EMERSON cov tub yees.
    Cov chav nyob yuav raug kuaj tag nrho ua ntej pob thiab Cov pob yuav raug kuaj xyuas kom zoo.

     

     

    Q3: Lub warranty yog dab tsi?
    A3: 1 xyoo lav rau txhua qhov chaw;Tag nrho lub neej ua haujlwm dawb!

     

     

    Q4: Koj puas yog cov chaw tsim khoom?
    A4: Yog lawm, peb muaj ntau tshaj 23 xyoos hauv kev lag luam tub yees.Peb lub Hoobkas nyob hauv Shenzhen;Txais tos tuaj xyuas peb txhua lub sijhawm.Kuj tseem muaj patent ntawm cov chillers tsim.

     

     

    Q5: Kuv tuaj yeem tso qhov kev txiav txim li cas?
    A5: Send us enquiry via email: sales@szhero-tech.com, call us via Cel number +86 15920056387 directly.