Feem ntau cov neeg siv khoom taw qhia, thiab nws yog peb lub hom phiaj kawg rau kev ua tsis yog tsuas yog cov neeg muab kev ntseeg siab tshaj plaws, kev ntseeg siab thiab ncaj ncees, tab sis kuj yog tus khub rau peb cov neeg siv khoom rau Hoobkas Nqe Rau R22 Hanbell / Bitzer Screw Compressor Condensing Unit, Tam sim no peb muaj plaub txoj kev daws teeb meem.Peb cov khoom muag zoo tshaj plaws muag tsis yog hauv Suav teb xwb, tab sis kuj tau txais tos los ntawm kev lag luam thoob ntiaj teb.
Feem ntau cov neeg siv khoom taw qhia, thiab nws yog peb lub hom phiaj kawg rau kev ua tsis yog tsuas yog cov neeg muab kev ntseeg siab tshaj plaws, ntseeg siab thiab ncaj ncees, tab sis kuj yog tus khub rau peb cov neeg siv khoom rau60HP Tuam Tshoj Cooler thiab Condensing Unit, Peb cov khoom tau lees paub dav thiab ntseeg tau los ntawm cov neeg siv khoom thiab tuaj yeem ua tau raws li cov kev xav tau ntawm kev lag luam thiab kev sib raug zoo.Peb zoo siab tos txais cov qhua tuaj noj mov tshiab thiab qub los ntawm txhua qhov chaw ntawm lub neej los tiv tauj peb rau kev lag luam kev sib raug zoo yav tom ntej thiab kev sib raug zoo!
Khoom taw qhia
HTS-W series industrial chiller yog siv rau hauv kev lag luam yas & roj hmab;Nws tuaj yeem tswj tau qhov kub thiab txias molding thiab txo lub voj voog molding, ua kom cov khoom zoo thiab txhim kho kev tsim khoom.Lawv kuj tau siv dav hauv Hlau ua haujlwm, Mechanical & Engineering, Tshuaj & Pharmaceutical, Khoom noj khoom haus & dej haus, Laser, Electronics kev lag luam, Textile, Electrolate, Semi-conductor testing, Dej dav hlau, Nqus txheej, Kev tsim kho thiab tub rog.
Daim ntawv thov
HERO-TECH chillers xa tus nqi rau ntau yam kev siv nrog kev siv zog ua kom zoo dua qub.
Nruab nrab thiab loj scale industrial txias
Central cua txias system
Txias chav, thermostatic chamber
Tsim nta
Paub zoo Brand Compressor
-Unit txais lub teb chaws Yelemees BITZER lossis Taiwan HANBELL hom semi-hermetic ntsia hlau compressor.Qhov tseeb 5 mus rau 6 patented ntsia hlau rotor profile nrog kev ua haujlwm zoo heev.
-4 qib tswj muaj peev xwm, 25% -50% -75% -100%.
-Adjustable infinite los yog ze stepped peev xwm tswj, nta lub zog npaum, ruaj khov thiab ntsiag to khiav.
Feem ntau patented siab precision manufacturing txheej txheem.
- Ua-nyob rau hauv tag nrho cov ntse saib xyuas thiab kev tiv thaiv nrog rau thermal lub cev muaj zog ntsuas kub xyuas, theem sib lawv liag xyuas, phau ntawv rov pib kaw-tawm, roj kub sensor.
- Ntau yam ntawm cov tub yees rau kev xaiv, suav nrog R134A, R407c thiab R22 (R404A, R507c raws li kev thov).
Microprogramming Control System
-Industrial PLC centralized tswj ua ke nrog compressor muaj peev xwm tswj system, precisely saib.
-Integrated tiv thaiv rau qhov kub thiab txias, siab / tsis tshua muaj siab, anti-freezing, theem uas ploj lawm, anti-phase, overload, lub cev muaj zog tshaj kub, roj sib txawv, ntws mus, pib latency.
-Txoj kev ua haujlwm hom lus, cov ntawv qhia zaub mov ua, chav tsev khiav lub xeev yooj yim kho.
Yooj yim installation, txhim khu kev qha khiav
- Kev pib ua haujlwm ze ze, txo qhov cuam tshuam rau hluav taws xob.
Ua haujlwm ruaj khov thiab muaj kev nyab xeeb, tsis tshua muaj kev vibration, yooj yim rau kev teeb tsa.
-Compact qauv, tsawg qhov chaw thov thiab lub teeb nyob rau hauv qhov hnyav, yooj yim rau kev thauj thiab installation.
-Ua tiav wired, tshuaj xyuas thiab kuaj ua ntej xa khoom, txuag lub sijhawm teeb tsa thiab tus nqi.
· Plhaub thiab raj evaporator thiab condenser, siab npaum xov liab tooj liab raj (khoom hloov ntawm kev thov).
· Siemens PLC tswj, LCD kov npo interface, ua haujlwm yooj yim, tus qauv tsim them.Schneider hluav taws xob Cheebtsam.
· R22, CFC Dawb R407C, R134A rau kev xaiv.
· 380V-415V / 50HZ3PH rau tus qauv tsim, Chiller chav tsev tuaj yeem muab tau raws li qhov xav tau sib txawv.
· Cov chaw me me yuav tsum tau ua, tsis xav tau qhov cua.
Kev Tiv Thaiv Kev Nyab Xeeb
- Compressor tiv thaiv sab hauv,
- tiv thaiv tam sim no
- Kev tiv thaiv siab / qis
- tiv thaiv kub dhau
- High tso tawm kub tswb
- flow rate tiv thaiv
-phase sequence/phase tsis muaj kev tiv thaiv
- low-level coolant tiv thaiv
-anti khov tiv thaiv
- Exhaust overheat tiv thaiv
Kev pabcuam
-Processional Team: Engineering pab pawg nrog nruab nrab 15 xyoo ntawm kev paub nyob rau hauv industrial tub yees, pab neeg muag khoom nrog nruab nrab 7 xyoo ntawm kev paub, pab pawg neeg nrog nruab nrab 10 xyoo ntawm kev paub.
-Txoj kev daws teeb meem ib txwm muab raws li qhov xav tau.
-3 kauj ruam kev tswj hwm zoo: kev tswj xyuas zoo, kev tswj xyuas zoo, kev tswj xyuas zoo.
-12 lub hlis lav rau tag nrho cov khoom.Tsis pub dhau lub warranty, txhua qhov teeb meem tshwm sim los ntawm qhov tsis xws ntawm chiller nws tus kheej, kev pabcuam muaj txog qhov teeb meem daws tau.
Tsib qhov zoo ntawm HERO-TECH
• Lub zog muaj zog:Peb yog cov kws tshaj lij thiab cov khoom lag luam saum toj kawg nkaus ntawm kev lag luam chiller nrog 20 xyoo ntawm kev paub.
• Kev cob qhia kws tshaj lij:Cov kws tshaj lij thiab paub txog cov kws tshaj lij & pab pawg muag khoom pabcuam rau kev lag luam txawv teb chaws, muab kev daws teeb meem raws li kev xav tau.
• Kev xa khoom sai:1/2hp rau 50hp cua txias chillers hauv Tshuag rau xa tam sim.
• Cov neeg ua haujlwm ruaj khov:Cov neeg ua haujlwm ruaj khov tuaj yeem ua kom ruaj khov thiab ua haujlwm zoo.Txhawm rau kom muaj kev pabcuam zoo thiab muaj txiaj ntsig zoo tom qab muag.
•Golden service:Kev pabcuam hu xovtooj tsis pub dhau 1 teev, kev daws teeb meem muaj nyob rau hauv 4hrs, thiab tus kheej kev teeb tsa thiab kev saib xyuas txawv teb chaws.
HERO-TECH EXHIBITION
Dej txias ntsia hlau chiller nrog ib qho compressor
Txias muaj peev xwm ntawm 30ton mus rau 300ton
Qauv: HTS-40W ~ HTS-100W
Qauv (HTS-***) | 40 W | 50 W | 60 W | 75w ua | 85w ua | 100 W | ||
Nominal txias muaj peev xwm | 7 ℃ | Kcal / h | 108962 ib | 143018 ib | 153682 ib | 20 5540 | 242176 ib | 284918 ib |
kw | 126.7 ib | 166.3 ib | 178.7 ib | 239.0 Nws | 281.6 ib | 331.1 ib | ||
12 ℃ | Kcal / h | 13 0118 | 170796 ib | 183524 ib | 245444 ib | 289218 ib | 340302 ib | |
kw | 151.3 ib | 198.6 ib | 213.4 ib | 285.4 ib | 3 36.3 | 395.7 ib | ||
Input zog | kw | 28 | 34.8 ib | 38.5 ib | 50.3 | 56.7 ib | 66.6 ib | |
Lub zog | 3PH 380V ~ 415V 50HZ / 220V ~ 600V 60HZ | |||||||
Cov tub yees | Hom | R22/R407C | ||||||
Them nqi | kg | 22 | 27 | 33 | 42 | 48 | 55 | |
Tswj | Thermostatic expansion valve | |||||||
Compressor | Hom | Semi-hermermetic ntsia hlau | ||||||
zog | kw | 28 | 34.8 ib | 38.5 ib | 50.3 | 56.7 ib | 66.6 ib | |
Pib hom | Y-△ | |||||||
Tswj peev xwm | % | 0-25-50-75-100 ib | ||||||
Evaporator | Hom | Plhaub thiab raj (ss phaj kub exchanger) | ||||||
Chilled dej ntim | m³/h | 20.5 ib | 26.1 ib | 29.5 ib | 39.5 ib | 45.6 ib | 49.7 ib | |
Dej siab poob | kPa ua | 32 | 35 | 38 | 42 | 42 | 45 | |
Cov yeeb nkab txuas | nti | 3 | 3 | 3 | 3 | 3 | 4 | |
Condenser | Hom | Plhaub thiab lub raj | ||||||
Chilled dej ntim | m³/h | 25 | 32.3 | 36.6 ib | 49.2 ib | 56 | 61.7 ib | |
Dej siab poob | kPa ua | 42 | 42 | 43 | 43 | 43 | 45 | |
Cov yeeb nkab txuas | nti | 3 | 3 | 3 | 3 | 3 | 4 | |
Cov khoom siv kev nyab xeeb | Compressor sab hauv kev tiv thaiv, dhau kev tiv thaiv tam sim no, kev tiv thaiv siab / tsis tshua muaj siab, tiv thaiv qhov kub thiab txias, tiv thaiv tus nqi ntws, theem sib lawv liag / theem tsis muaj kev tiv thaiv, tsis tshua muaj cua txias tiv thaiv, tiv thaiv kev tiv thaiv khov, tiv thaiv cua sov | |||||||
Dimension | Ntev | mm | 2500 | 2550 | 2600 | 2800 | 2800 | 2900 ib |
Dav | mm | 780 ua | 780 ua | 780 ua | 950 ua | 950 ua | 950 ua | |
Qhov siab | mm | 1650 | 1650 | 1650 | 1800 | Xyoo 1950 | Xyoo 1950 | |
Net nyhav | kg | 900 | 1050 | 1200 | 1800 | Xyoo 1900 | 2050 | |
Khiav hnyav | kg | 1050 | 1200 | 1350 | Xyoo 1980 | 2150 | 2250 | |
Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no:
Peb muaj txoj cai los hloov cov kev qhia tshwj xeeb yam tsis muaj kev ceeb toom ntxiv. |
HTS 120W ~ 270W
Qauv (HTS-***) | 120 W | 150 W | 180 W | 200 W | 240 W | 270 W | ||
Nominal txias muaj peev xwm | 7 ℃ | Kcal / h | 3 33680 | 4 2350 | 510926 ib | 6 05526 | 718616 ib | 794984 ib |
kw | 388.0 ib | 492.5 ib | 594.1 ib | ib 704.1 | 835.6 ib | 924.4 ib | ||
12 ℃ | Kcal / h | 398438 ib | 5 05852 | 6 10170 | 723174 ib | 858194 ib | 949354 ib | |
kw | 463.3 ib | 588.2 ib | ib 709.5 | 840.9 ib | 997.9 ib | 1 103.9 | ||
Input zog | kw | 79.6 ib | 98.6 ib | 120.4 ib | 140.1 ib | 166.8 ib | 184.7 ib | |
Lub zog | 3PH 380V ~ 415V 50HZ / 220V ~ 600V 60HZ | |||||||
Cov tub yees | Hom | R22/R407C | ||||||
Them nqi | kg | 68 | 88 | 110 | 121 | 143 | 165 | |
Tswj | Thermostatic expansion valve | |||||||
Compressor | Hom | Semi-hermetic ntsia hlau | ||||||
zog | kw | 79.6 ib | 98.6 ib | 120.4 ib | 140.1 ib | 166.8 ib | 184.7 ib | |
Pib hom | Y-△ | |||||||
Tswj peev xwm | % | 0-25-50-75-100 ib | ||||||
Evaporator | Hom | Plhaub thiab raj (ss phaj kub exchanger) | ||||||
Chilled dej ntim | m³/h | 62.4 ib | 81 | 98 | 115 | 135.7 ib | 153 | |
Dej siab poob | kPa ua | 40 | 43 | 45 | 45 | 43 | 47 | |
Cov yeeb nkab txuas | nti | 4 | 5 | 6 | 6 | 6 | 6 | |
Condenser | Hom | Plhaub thiab lub raj | ||||||
Chilled dej ntim | m³/h | 77 | 101 | 125 | 125 | 170 | 191 | |
Dej siab poob | kPa ua | 48 | 46 | 48 | 48 | 45 | 47 | |
Cov yeeb nkab txuas | nti | 4 | 3 * 2 | 3 * 2 | 4 * 2 | 4 * 2 | 4 * 2 | |
Cov khoom siv kev nyab xeeb | Compressor sab hauv kev tiv thaiv, dhau kev tiv thaiv tam sim no, kev tiv thaiv siab / tsis tshua muaj siab, tiv thaiv qhov kub thiab txias, tiv thaiv tus nqi ntws, theem sib lawv liag / theem tsis muaj kev tiv thaiv, tsis tshua muaj cua txias tiv thaiv, tiv thaiv kev tiv thaiv khov, tiv thaiv cua sov | |||||||
Dimension | Ntev | mm | 3000 | 3300 ib | 3800 ib | 3900 ib | 4300 ib | 4500 |
Dav | mm | 1200 | 1380 | 1380 | 1380 | 1480 | 1480 | |
Qhov siab | mm | 1580 | 1630 | 1750 | 1750 | 1780 | 1780 | |
Net nyhav | kg | 2500 | 2650 | 3 150 | 3 350 | 3 850 | ib 4160 | |
Khiav hnyav | kg | 2700 ib | 2900 ib | 3400 ib | 3 650 | 4 150 | ib 4460 | |
Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no:
Peb muaj txoj cai los hloov cov kev qhia tshwj xeeb yam tsis muaj kev ceeb toom ntxiv. |
Dej txias Screw chillers nrog Ob chav compressors
HTS-100WD ~ HTS-300WD
Qauv (HTS-***) | 100 WD | 120 WD | 150 WD | 180 wb | 200 WD | 240 W | 280 W | 300 WD | ||
Nominal txias muaj peev xwm | 7 ℃ | Kcal / h | 286036 ib | 307364 ib | 4 11080 | 511872 ib | 569836 ib | 6 67360 | 794468 ib | 847100 ib |
kw | 332.6 ib | 357.4 ib | 478.0 ib | 595.2 ib | 662.6 ib | ib 776.0 | 923.8 ib | 985.0 ua | ||
12 ℃ | Kcal / h | 341592 ib | 367048 ib | 4 9088 | 611288 ib | 680604 ib | 796876 ib | 948924 ib | 1011704 ib | |
kw | 397.2 ib | 426.8 ib | 570.8 ib | 710.8 ib | ib 791.4 | 926.6 ib | 1 103.4 | 1176.4 ib | ||
Input zog | kw | 69.6 ib | 77 | 100.6 | 123.4 ib | 133.2 ib | 159.2 ib | 183.8 ib | 197.2 ib | |
Lub zog | 3PH 380V ~ 415V 50HZ / 220V ~ 600V 60HZ | |||||||||
Cov tub yees | Hom | R22/C407C | ||||||||
Them nqi | kg | 27 * 2 | 33 * 2 | 42 * 2 | 48 * 2 | 55 * 2 | 68 * 2 | 77 * 2 | 88 * 2 | |
Tswj | Thermostatic expansion valve | |||||||||
Compressor | Hom | Semi-hermetic ntsia hlau | ||||||||
Hwj chim | kw | 34.8 * 2 | 38.5 * 2 | 50.3 * 2 | 61.7 * 2 | 66.6 * 2 | 79.6 * 2 | 91.9 * 2 | 98.6 * 2 | |
Pib hom | Y-△ | |||||||||
Tswj peev xwm | % | 0-25-50-75-100 ib | ||||||||
Evaporator | Hom | Plhaub thiab lub raj | ||||||||
Chilled dej ntim | m³/h | 52.2 ib | 59 | 79 | 91.2 ib | 99.4 ua | 124.8 ib | 151.6 ib | 162 | |
Dej siab poob | kPa ua | 42 | 42 | 46 | 43 | 45 | 45 | 43 | 48 | |
Cov yeeb nkab txuas | nti | 4 | 4 | 5 | 6 | 6 | 6 | 6 | 8 | |
Condenser | Hom | |||||||||
Chilled dej ntim | m³/h | 64.6 ib | 73.2 ib | 98.4 ua | 112 | 123.4 ib | 154 | 191 | 202 | |
Dej siab poob | kPa ua | 41 | 42 | 42 | 45 | 48 | 46 | 48 | 48 | |
Cov yeeb nkab txuas | nti | 4 | 4 | 3 * 2 | 3 * 2 | 4 * 2 | 4 * 2 | 4 * 2 | 5 * 2 | |
Cov khoom siv kev nyab xeeb | Compressor sab hauv kev tiv thaiv, dhau kev tiv thaiv tam sim no, kev tiv thaiv siab / tsis tshua muaj siab, tiv thaiv qhov kub thiab txias, tiv thaiv tus nqi ntws, theem sib lawv liag / theem tsis muaj kev tiv thaiv, tsis tshua muaj cua txias tiv thaiv, tiv thaiv kev tiv thaiv khov, tiv thaiv cua sov | |||||||||
Dimension | Ntev | mm | 2800 | 2950 ib | 3 150 | ib 3480 | ib 3480 | 3 650 | 3 650 | 3750 ib |
Dav | mm | 780 ua | 810 | 850 | 875 ib | 895 ib | 1120 | 1220 | 1300 | |
Qhov siab | mm | 1650 | 1650 | 1750 | 1850 | 1850 | Xyoo 1950 | Xyoo 1950 | 2100 | |
Net nyhav | kg | 1850 | 2200 | 2650 | 2800 | 3 450 | ib 3950 | 4 100 | 4 450 | |
Khiav hnyav | kg | 2150 | 2500 | ib 2970 | 3400 ib | ib 4160 | 4 350 | 4700 ib | 5 050 | |
Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no:
Peb muaj txoj cai los hloov cov kev qhia tshwj xeeb yam tsis muaj kev ceeb toom ntxiv. |
HTS-360WD ~ HTS-540WD
Qauv (HTS-***) | 360 wb | 400 wb | 460 wb | 480 wb | 540 wb | ||
Nominal txias muaj peev xwm | 7 ℃ | Kcal / h | 1021852 ib | 1211052 ib | 13 20616 ib | 1437232 ib | 158968 ib |
kw | 1188.2 ib | 1408.2 ib | 15 35.6 | 1671.2 ib | 1848.8 ib | ||
12 ℃ | Kcal / h | 12 20340 ib | 1446348 ib | 1577068 ib | 1681988 ib | 1898708 ib | |
kw | 1419.0 Nws | 1681.8 ib | 18 33.8 | 1955.8 Nws | 2207.8 ib | ||
Input zog | kw | 240.8 ib | 280.2 ib | 314 | 333.6 ib | 369.4 ib | |
Lub zog | 3PH 380V ~ 415V 50HZ / 60HZ | ||||||
Cov tub yees | Hom | R22 | |||||
Them nqi | kg | 110 * 2 | 121 * 2 | 132 * 2 | 143 * 2 | 165 * 2 | |
Tswj | Thermostatic expansion valve | ||||||
Compressor | Hom | Semi-hermetic ntsia hlau | |||||
Hwj chim | kw | 120 * 2 | 140 * 2 | 157 * 2 | 167 * 2 | 185 * 2 | |
Pib hom | Y-△ | ||||||
Tswj peev xwm | % | 0-25-50-75-100 ib | |||||
Evaporator | Hom | Plhaub thiab lub raj | |||||
Chilled dej ntim | m³/h | 169 | 231.4 ib | 254 | 271.4 ib | 306 | |
Dej siab poob | kPa ua | 44 | 45 | 42 | 45 | 46 | |
Cov yeeb nkab txuas | nti | 8 | 8 | 10 | 10 | 10 | |
Condenser | Hom | Plhaub thiab lub raj | |||||
Chilled dej ntim | m³/h | 248 | 290 | 318 | 340 | 382 ib | |
Dej siab poob | kPa ua | 46 | 42 | 48 | 48 | 48 | |
Cov yeeb nkab txuas | nti | 5 * 2 | 5 * 2 | 5 * 2 | 6 * 2 | 6 * 2 | |
Cov khoom siv kev nyab xeeb | Compressor sab hauv kev tiv thaiv, dhau kev tiv thaiv tam sim no, kev tiv thaiv siab / tsis tshua muaj siab, tiv thaiv qhov kub thiab txias, tiv thaiv tus nqi ntws, theem sib lawv liag / theem tsis muaj kev tiv thaiv, tsis tshua muaj cua txias tiv thaiv, tiv thaiv kev tiv thaiv khov, tiv thaiv cua sov | ||||||
Dimension | Ntev | mm | 4230 ib | 4230 ib | 4 350 | 4 350 | 4420 ib |
Dav | mm | 1380 | 1480 | 1450 | 1560 | 1650 | |
Qhov siab | mm | 2150 | 2250 | 2250 | 2300 | 2450 | |
Net nyhav | kg | 5000 | 5 250 | 5500 | 5750 ua | 6000 | |
Khiav hnyav | kg | 5700 ib | ib 5950 | 6 100 | ib 6350 | 6600 ib | |
Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no:
Peb muaj txoj cai los hloov cov kev qhia tshwj xeeb yam tsis muaj kev ceeb toom ntxiv. |
Plaub compressors
HTS-300WF ~ HTS-1080WF
Qauv (HTS-***) | 300 wb | 340 wb | 400 wb | 480 wb | 600 wb | 680 wb | 800 wb | 920 wb | 950 wb | 1080 AWV | ||
Nominal txias muaj peev xwm | 7 ℃
| Kcal / h | 82216 0 | 968704 ib | 1139672 ib | 1334720 ib | 1694200 ib | 1997608 ib | 2422104 ib | 2641232 ib | 2874120 ib | 317936 ib |
kw | 956.0 ua | 1 126.4 | 1325.2 ib | 1552.0 Nws | Xyoo 1970.0 | 2322.8 ib | 2816.4 ib | 3071.2 ib | 3 342.0 | 3697.6 ib | ||
ton | 271 | 320 | ib 376 | 441 ib | 560 | 660 | 800 | 873 ib | 950 ua | 1051 ib | ||
12 ℃ | Kcal / h | 98176 ib | 1156872 ib | 1361208 ib | 1593752 ib | 2023408 ib | 23 85640 | 2892696 ib | 3154136 ib | 3363976 ib | 3797416 ib | |
kw | 1 141.6 | 1345.2 ib | 1582.8 ib | 1853.2 ib | 2352.8 ib | 2774.0 ib | 3 363.6 | 3667.6 ib | 3911.6 ib | 4 415.6 | ||
ton | 324 | 382 ib | 450 | 526 ib | 668 ib | 788 ib | 956 ib | 1042 ib | 1112 | 1255 | ||
Input zog | kw | 201 | 226 | 266 | 318 | 394 ib | 466 ib | 560 | 628 ib | 666 ib | 738 ib | |
Lub zog | 3PH 380V ~ 415V 50HZ / 220V ~ 600V 60HZ | |||||||||||
Lub tub yees | Hom | R22/R407C | ||||||||||
Them nqi | kg | 42 * 4 | 48 * 4 | 55 * 4 | 68 * 4 | 88 * 4 | 108 * 4 | 121 * 4 | 132 * 4 | 143 * 4 | 165 * 4 | |
Tswj | Thermostatic expansion valve | |||||||||||
Compressor | Hom | Semi-hermetic ntsia hlau | ||||||||||
Hwj chim | kw | 50 * 4 | 56.5 * 4 | 66.5 * 4 | 79.5 * 4 | 98.5 * 4 | 116 * 4 | 140 * 4 | 157 * 4 | 166 * 4 | 184 * 4 | |
Pib hom | Y-△ | |||||||||||
Tswj peev xwm | % | 0-25-50-75-100 ib | ||||||||||
Evaporator | Hom | Plhaub thiab lub raj | ||||||||||
Chilled dej ntim | m³/h | 158 | 182.4 ib | 198.8 ib | 249.6 ib | 324 | 382.8 ib | 462.8 ib | 508 | 542.8 ib | 612 | |
Dej siab poob | kPa ua | 46 | 43 | 45 | 45 | 48 | 43 | 45 | 42 | 45 | 46 | |
Cov yeeb nkab txuas | nti | 8 * 2 | 8 * 2 | 10 * 2 | 10 * 2 | 10 * 2 | 10 * 2 | 12 * 2 | 12 * 2 | 8 * 4 | 8 * 4 | |
Condenser | Hom | Plhaub thiab lub raj | ||||||||||
Cov dej txias txias | m³/h | 196.8 ib | 224 | 246.8 ib | 308 | 404 | 476 ib | 580 | 636 ib | 680 | 764 ib | |
Dej siab poob | kPa ua | 42 | 45 | 48 | 46 | 48 | 45 | 42 | 48 | 48 | 48 | |
Cov yeeb nkab txuas | nti | 6 * 2 | 6 * 2 | 8 * 2 | 8 * 2 | 8 * 2 | 4 * 4 | 4 * 4 | 6 * 4 | 6 * 4 | 6 * 4 | |
Cov khoom siv kev nyab xeeb | Compressor sab hauv kev tiv thaiv, dhau kev tiv thaiv tam sim no, kev tiv thaiv siab / tsis tshua muaj siab, tiv thaiv qhov kub thiab txias, tiv thaiv tus nqi ntws, theem sib lawv liag / theem tsis muaj kev tiv thaiv, tsis tshua muaj cua txias tiv thaiv, tiv thaiv kev tiv thaiv khov, tiv thaiv cua sov | |||||||||||
Dimension | Ntev | mm | 3 150 | ib 3480 | ib 3480 | 3 650 | 3750 ib | 3750 ib | 4230 ib | 4 350 | 4 350 | 4420 ib |
Dav | mm | 1700 | 1750 | 1790 ib | 2240 ib | 2600 | 2900 ib | ib 2960 | 2900 ib | 3300 ib | 3300 ib | |
Qhov siab | mm | 1750 | 1850 | 1850 | Xyoo 1950 | 2100 | 2150 | 2250 | 2250 | 2300 | 2450 | |
Net nyhav | kg | 2650 | 2800 | 3 450 | ib 3950 | 4 450 | 4700 ib | 5 250 | 5500 | 5750 ua | 6000 | |
Khiav hnyav | kg | 3200 | ib 3380 | ib 4160 | ib 4760 | 5270 ib | ib 5460 | 6 100 | 6400 ib | ib 6680 | ib 6970 | |
Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no:
Peb muaj txoj cai los hloov cov kev qhia tshwj xeeb yam tsis muaj kev ceeb toom ntxiv. |
Q1: Koj puas tuaj yeem pab peb kom pom zoo tus qauv rau peb qhov project?
A1: Yog lawm, peb muaj engineer los xyuas cov ntsiab lus thiab xaiv tus qauv raug rau koj.Raws li cov hauv qab no:
1) Lub peev xwm txias;
2) Yog tias koj tsis paub, koj tuaj yeem muab tus nqi ntws rau koj lub tshuab, qhov kub thiab txias tawm ntawm koj qhov siv;
3) Ib puag ncig kub;
4) Hom tub yees, R22, R407c lossis lwm yam, pls qhia meej;
5) Voltage;
6) Daim ntawv thov kev lag luam;
7) Cov twj tso kua mis ntws thiab siab xav tau;
8) Lwm yam kev cai tshwj xeeb.
Q2: Yuav ua li cas kom ntseeg tau koj cov khoom zoo?
A2: Tag nrho peb cov khoom nrog daim ntawv pov thawj CE thiab peb lub tuam txhab nruj me ntsis ua raws li ISO900 kev tswj xyuas zoo.Peb siv cov khoom lag luam nto moo thoob ntiaj teb, xws li DANFOSS, COPELAND, SANYO, BITZER, HANBELL compressors, Schneider hluav taws xob Cheebtsam, DANFOSS / EMERSON cov tub yees.
Cov chav nyob yuav raug kuaj tag nrho ua ntej pob thiab Cov pob yuav raug kuaj xyuas kom zoo.
Q3: Lub warranty yog dab tsi?
A3: 1 xyoo lav rau txhua qhov chaw;Tag nrho lub neej ua haujlwm dawb!
Q4: Koj puas yog cov chaw tsim khoom?
A4: Yog lawm, peb muaj ntau tshaj 23 xyoos hauv kev lag luam tub yees.Peb lub Hoobkas nyob hauv Shenzhen;Txais tos tuaj xyuas peb txhua lub sijhawm.Kuj tseem muaj patent ntawm cov chillers tsim.
Q5: Kuv tuaj yeem tso qhov kev txiav txim li cas?
A5: Send us enquiry via email: sales@szhero-tech.com, call us via Cel number +86 15920056387 directly.