Ob peb xyoos dhau los, peb lub tuam txhab tau nqus thiab zom cov thev naus laus zis zoo sib xws hauv tsev thiab txawv teb chaws.Lub caij no, peb cov neeg ua haujlwm ua lag luam ib pab pawg kws tshaj lij tau mob siab rau kev loj hlob ntawm Tuam Tshoj Cov Khoom Tshiab Zoo Roj Chiller, Raws li kev lag luam lub tswv yim zoo ua ntej, peb xav ntsib ntau tus phooj ywg hauv lo lus thiab peb vam tias yuav muab cov khoom lag luam zoo tshaj plaws thiab kev pabcuam rau koj.
Ob peb xyoos dhau los, peb lub tuam txhab tau nqus thiab zom cov thev naus laus zis zoo sib xws hauv tsev thiab txawv teb chaws.Lub caij no, peb cov neeg ua haujlwm ua lag luam ib pab pawg kws tshaj lij tau mob siab rau kev loj hlob ntawmTuam Tshoj Lub Nroog Dej Txias Cia thiab Kho Mob Txias Cia, Peb muab zoo zoo tab sis unbeatable uas tsis muaj nqi thiab cov kev pab zoo tshaj plaws.Txais tos kom xa koj cov qauv thiab xim nplhaib rau peb .Peb yuav tsim cov khoom raws li koj qhov kev thov.Yog tias koj txaus siab rau ib qho kev daws teeb meem uas peb muab, nco ntsoov tiv tauj peb ncaj qha los ntawm kev xa ntawv, fax, xov tooj lossis internet.Peb tau nyob ntawm no los teb koj cov lus nug txij hnub Monday txog hnub Saturday thiab tos ntsoov yuav koom tes nrog koj.
Khoom taw qhia
Roj chiller yog dav siv nyob rau hauv txias ntawm lub ntsiab ncej lube roj thiab hydraulic roj ntawm CNC tshuab, jig tho txawv tshuab, grinder machining chaw, sib xyaw tshuab cuab yeej thiab lwm yam precision tshuab cuab tam.Roj chiler yog tsim los tswj cov roj kub kom zoo, tsis txhob muaj cua sov distortion, yog li txhawm rau xyuas kom meej machining precision.
Tsim nta
- Txais European lossis Japanese hom compressor, kev ua haujlwm ruaj khov, ua haujlwm siab thiab qis suab nrov.
-HTOl series immersion hom roj chiller nruab tooj liab coil hom evaporator, tsis muaj tank.HTo series roj chiller nruab nrog tooj liab coil-hauv-tank hom evaporator, thiab plhaub thiab raj hom evaporator rau kev xaiv.
-Cov khoom siv hluav taws xob muaj npe nrov tau ua haujlwm los xyuas kom lub neej ua haujlwm ntev.
-Tshwj xeeb tsim tswj system, ± 1 ℃ tswj qhov tseeb.
-Ntshuam roj twj tso kua mis rau cov kua kub kub, siab siab, loj txaus tus nqi thiab ruaj khov.
-R22 them rau tus qauv tsim, R407C, R134A, R410A rau kev xaiv.
-Kev tiv thaiv tag nrho rau lub cev, suav nrog kev kub siab / tsis tshua muaj siab, siab tawm qhov kub, compressor lub cev muaj zog overheat, dhau tam sim no, tiv thaiv khov, ntws hloov thiab hloov pauv ceev.
-1 / 2HP rau 2HP: 1PH 220V / 50HZ.
-3HP thiab siab dua: 3PH 380-V-415V / 50HZ.
Lub zog tuaj yeem hloov tau raws li qhov xav tau.
- Danfoss / Copeland scroll compressor.
- Tsawg suab nrov axial kiv cua lub cev muaj zog, ntsiag to khiav.
Daim ntawv thov
- Tshuab dhos, siab ceev tshuab dhos
- CNC tshuab
-Jig tho txawv tshuab
-combined tshuab cuab tam thiab lwm yam precision tshuab cuab tam
-Internal-sab nraud lapping tshuab
-Electron Discharge Machining
- Hydraulic xovxwm equipments
-Grinder, broaching tshuab, milling tshuab
-Comprehensive processing center
- Ntoo engraving tshuab, khoom txiav ntoo, thiab lwm yam.
Dependable, ntau yam, high-efficiency txias.
HERO-TECH chillers xa tus nqi rau ntau yam kev siv nrog kev siv zog ua kom zoo dua qub.
Kev Tiv Thaiv Kev Nyab Xeeb
- Compressor tiv thaiv sab hauv,
- dhau kev tiv thaiv tam sim no,
- Kev tiv thaiv siab / qis,
- tiv thaiv kub dhau,
- High tso tawm kub tswb
- flow rate tiv thaiv,
-phase sequence/phase tsis muaj kev tiv thaiv,
- low-level coolant tiv thaiv,
-Anti khov tiv thaiv,
- Exhaust overheat tiv thaiv
Kev pabcuam
-Processional Team: Engineering pab pawg nrog nruab nrab 15 xyoo ntawm kev paub nyob rau hauv industrial tub yees, pab neeg muag khoom nrog nruab nrab 7 xyoo ntawm kev paub, pab pawg neeg nrog nruab nrab 10 xyoo ntawm kev paub.
-Txoj kev daws teeb meem ib txwm muab raws li qhov xav tau.
-3 kauj ruam kev tswj hwm zoo: kev tswj xyuas zoo, kev tswj xyuas zoo, kev tswj xyuas zoo.
-12 lub hlis lav rau tag nrho cov khoom.Tsis pub dhau lub warranty, txhua qhov teeb meem tshwm sim los ntawm qhov tsis xws ntawm chiller nws tus kheej, kev pabcuam muaj txog qhov teeb meem daws tau.
Tsib qhov zoo ntawm HERO-TECH
•Hom lub zog : Peb yog cov kws tshaj lij thiab cov khoom lag luam sab saum toj ntawm cov tshuab chiller nrog 20 xyoo ntawm kev paub.
• Kev cob qhia kev cob qhia: Cov kws tshaj lij thiab cov kws tshaj lij & pab pawg muag khoom pabcuam rau kev lag luam txawv teb chaws, muab cov kev daws teeb meem raws li kev xav tau.
• Kev xa khoom sai: 1/2hp txog 50hp cua txias chillers hauv Tshuag rau kev xa khoom tam sim.
• Cov neeg ua haujlwm ruaj khov : Cov neeg ua haujlwm ruaj khov tuaj yeem ua kom ruaj khov thiab ua haujlwm zoo.Txhawm rau kom muaj kev pabcuam zoo thiab muaj txiaj ntsig zoo tom qab muag.
•Golden kev pabcuam : Kev pabcuam hu xovtooj hauv 1 teev, kev daws teebmeem hauv 4hrs, thiab muaj pab pawg ua haujlwm txawv tebchaw thiab tu.
Immersion hom roj chiller:
Qauv (HTOI-***) | 1/2 A | 1A | 1-1/2A | 2A | 3A | ||
Hom tsim | Immersion hom roj chiller | ||||||
Nominal txias muaj peev xwm | Kcal / h | 1616 | 3242 ib | ib 4859 | ib 6475 | ib 9709 | |
kw | 1.88 ib | 3.77 ib | 5.65 ib | 7.53 ib | 11.29 Nws | ||
Input zog | kw | 0.545 ib | 1.03 ib | 1.7 | 1.91 ib | 2.78 ib | |
Lub zog | 1PH 220V 50HZ / 3PH 380V ~ 415V 50HZ / 60HZ | ||||||
Roj kub ntau yam | 20 ℃ to 35 ℃ | ||||||
Cov tub yees | Hom | R22 | |||||
Tswj | Capillary | ||||||
Compressor | Hom | Hermetic-rotary / Hermetic scroll | |||||
Lub cev muaj zog | kw | 0.45 ib | 0.89 ib | 1.52 ib | 1.73 ib | 2.5 | |
Condenser | Hom | High efficiency aluminium finned coil + lub ntim loj uas tsis muaj suab nrov axial kiv cua | |||||
Cua ntim | m³/h | 750 | 1000 | 1500 | 2000 | 3000 | |
Ntxuam zog | kw | 0.095 ib | 0.14 ib | 0.18 | 0.18 | 0.14 * 2 | |
Evaporator | Hom | Tank nrog tooj liab coil / plhaub thiab raj | |||||
Chilled roj ntim | m³/h | 1.08 Nws | 1.8 | 2.3 | 3.6 | 5.4 | |
Cov khoom siv kev nyab xeeb | Compressor sab hauv kev tiv thaiv, dhau kev tiv thaiv tam sim no, kev tiv thaiv siab / tsis tshua muaj siab, tiv thaiv qhov kub thiab txias, tiv thaiv tus nqi ntws, theem sib lawv liag / theem tsis muaj kev tiv thaiv, tsis tshua muaj cua txias tiv thaiv, tiv thaiv kev tiv thaiv khov, tiv thaiv cua sov | ||||||
Dimension | Ntev | mm | 500 | 550 | 620 | 620 | 1030 |
Dav | mm | 350 | 450 | 500 | 500 | 680 | |
Qhov siab | mm | 755 ib | 885 ib | 1030 | 1030 | 1330 ib | |
Net nyhav | kg | 40 | 47 | 63 | 78 | 116 | |
Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no: |
Ntim hom roj chiller:
Qauv (HTO-***) | 1/2 A | 1A | 1-1/2A | 2A | 3A | 5A | 6A | 8A | 10 A | ||
Hom tsim | Ntim hom roj chiller | ||||||||||
Nominal txias muaj peev xwm | Kcal / h | 1616 | 3242 ib | ib 4859 | ib 6475 | ib 9709 | ib 16193 | 19427 ib | 25903 ib | ib 32379 | |
kw | 1.88 ib | 3.77 ib | 5.65 ib | 7.53 ib | 11.29 Nws | 18.83 Nws | 22.59 Nws | 30.12 Nws | 37.65 Nws | ||
Input zog | kw | 0.915 ib | 1.4 | 2.25 | 2.46 ib | 3.53 ib | 5.06 ib | 5.77 ib | 7.9 ib | 9.76 ib | |
Lub zog | 1 PH 220V 50HZ | 3PH 380V ~ 415V 50HZ / 60HZ | |||||||||
Roj kub ntau yam | 20 ℃ to 35 ℃ | ||||||||||
Cov tub yees | Hom |
| R22 | ||||||||
Tswj |
| Capillary | Thermostatic expansion valve | ||||||||
Compressor | Hom |
| Hermetic-rotary | Hermetic scroll | |||||||
Lub cev muaj zog | kw | 0.45 ib | 0.89 ib | 1.52 ib | 1.73 ib | 2.5 | 3.68 ib | 4.31 ib | 2.95 * 2 | 3.68 * 2 | |
Condenser | Hom |
| High efficiency aluminium finned coil + lub ntim loj uas tsis muaj suab nrov axial kiv cua | ||||||||
Cua ntim | m³/h | 750 | 1000 | 1500 | 2000 | 3000 | 5000 | 6000 | 8000 | 10000 | |
Ntxuam zog | kw | 0.095 ib | 0.14 ib | 0.18 | 0.18 | 0.14 * 2 | 0.14 * 2 | 0.18 * 2 | 0.25 * 2 | 0.45 * 2 | |
Evaporator | Hom |
| Tank nrog tooj liab coil / plhaub thiab raj | ||||||||
Chilled roj ntim | m³/h | 1.08 Nws | 1.8 | 2.3 | 3.6 | 5.4 | 9 | 10.4 | 14.4 ib | 18 | |
Cov yeeb nkab txuas | nti | 1/2 | 1/2 | 1/2 | 1/2 | 3/4 | 1 | 1 | 1-1/2 | 1-1/2 | |
Roj twj tso kua mis | Hwj chim | kw | 0.37 ib | 0.37 ib | 0.55 ib | 0.55 ib | 0.75 ib | 1.1 | 1.1 | 1.5 | 1.5 |
Nqa | m | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |
Cov khoom siv kev nyab xeeb | Compressor sab hauv kev tiv thaiv, dhau kev tiv thaiv tam sim no, kev tiv thaiv siab / tsis tshua muaj siab, tiv thaiv qhov kub thiab txias, tiv thaiv tus nqi ntws, theem sib lawv liag / theem tsis muaj kev tiv thaiv, tsis tshua muaj cua txias tiv thaiv, tiv thaiv kev tiv thaiv khov, tiv thaiv cua sov | ||||||||||
Dimension | Ntev | mm | 550 | 600 | 650 | 650 | 1030 | 1030 | 1170 ib | 1350 | 1550 |
Dav | mm | 350 | 400 | 520 | 520 | 560 | 560 | 610 | 680 | 760 ib | |
Qhov siab | mm | 755 ib | 885 ib | 1030 | 1030 | 1330 ib | 1330 ib | 1390 ib | 1520 | 1680 | |
Net nyhav | kg | 45 | 52 | 65 | 85 | 132 | 165 | 183 | 275 | 355 | |
Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no: |
Q1: Koj puas tuaj yeem pab peb kom pom zoo tus qauv rau peb qhov project?
A1: Yog lawm, peb muaj engineer los xyuas cov ntsiab lus thiab xaiv tus qauv raug rau koj.Raws li cov hauv qab no:
1) Lub peev xwm txias;
2) Yog tias koj tsis paub, koj tuaj yeem muab tus nqi ntws rau koj lub tshuab, qhov kub thiab txias tawm ntawm koj qhov siv;
3) Ib puag ncig kub;
4) Hom tub yees, R22, R407c lossis lwm yam, pls qhia meej;
5) Voltage;
6) Daim ntawv thov kev lag luam;
7) Cov twj tso kua mis ntws thiab siab xav tau;
8) Lwm yam kev cai tshwj xeeb.
Q2: Yuav ua li cas kom ntseeg tau koj cov khoom zoo?
A2: Tag nrho peb cov khoom nrog daim ntawv pov thawj CE thiab peb lub tuam txhab nruj me ntsis ua raws li ISO900 kev tswj xyuas zoo.Peb siv cov khoom lag luam nto moo thoob ntiaj teb, xws li DANFOSS, COPELAND, SANYO, BITZER, HANBELL compressors, Schneider hluav taws xob Cheebtsam, DANFOSS / EMERSON cov tub yees.
Cov chav nyob yuav raug kuaj tag nrho ua ntej pob thiab Cov pob yuav raug kuaj xyuas kom zoo.
Q3: Lub warranty yog dab tsi?
A3: 1 xyoo lav rau txhua qhov chaw;Tag nrho lub neej ua haujlwm dawb!
Q4: Koj puas yog cov chaw tsim khoom?
A4: Yog lawm, peb muaj ntau tshaj 23 xyoos hauv kev lag luam tub yees.Peb lub Hoobkas nyob hauv Shenzhen;Txais tos tuaj xyuas peb txhua lub sijhawm.Kuj tseem muaj patent ntawm cov chillers tsim.
Q5: Kuv tuaj yeem tso qhov kev txiav txim li cas?
A5: Send us enquiry via email: sales@szhero-tech.com, call us via Cel number +86 15920056387 directly.