I-Screw Type Chiller epholile ngamanzi

Incazelo emfushane:

Isingeniso somkhiqizo we-HTS-W uchungechunge lwe-chiller yezimboni lusetshenziswa kakhulu embonini yePlastiki neRubber;Ingakwazi ukulawula ngokunembile izinga lokushisa lokubumba futhi ifinyeze umjikelezo wokubumba, ikhulise ikhwalithi yomkhiqizo futhi ithuthukise ukusebenza kahle kokukhiqiza.Zibuye zisetshenziswe kabanzi ekusebenzeni kweMetal, Mechanical & Engineering, Chemical & Pharmaceutical, Food & Beverage, Laser, Electronics industry, Textile, Electroplate, Semi-conductor testing, Water jet, Vacuum coating, Constructi...


Imininingwane Yomkhiqizo

Imingcele yomkhiqizo

ukupakisha nokuthutha

isitifiketi

faq

https://youtu.be/QErvGl_C3tU

 

Isingeniso somkhiqizo


I-HTS-W series chiller yezimboni isetshenziswa kakhulu embonini yePlastiki & Rubber;Ingakwazi ukulawula ngokunembile izinga lokushisa lokubumba futhi ifinyeze umjikelezo wokubumba, ikhulise ikhwalithi yomkhiqizo futhi ithuthukise ukusebenza kahle kokukhiqiza.Zibuye zisetshenziswe kabanzi ekusebenzeni kweMetal, Mechanical & Engineering, Chemical & Pharmaceutical, Food & Beverage, Laser, Electronics industry, Textile, Electroplate, Semi-conductor testing, Water jet, Vacuum coating, Construction and Military.

  

Isicelo

Ama-chiller e-HERO-TECH aletha inani ezinhlobonhlobo zezinhlelo zokusebenza ezinezinketho ezithuthukisiwe zokonga amandla.

Ukupholisa izimboni ngezinga elimaphakathi nelikhulu
Isistimu ye-air conditioning ephakathi
Igumbi elibandayo, igumbi le-thermostatic

isikulufa chiller isicelo

Izici zokuklama

I-Compressor Yomkhiqizo Eyaziwa Kahle
-Iyunithi yamukela i-Germany BITZER noma i-Taiwan HANBELL brand semi-hermetic screw compressor.Iphrofayela yakamuva ye-screw rotor engu-5 kuya ku-6 esebenza kahle kakhulu.

-4 grade control umthamo, 25% -50% -75% -100%.
-Ukulawula umthamo okungaguqukiyo noma okunyathelwe eduze, kuhlanganisa ukonga amandla, ukugijima okuzinzile nokuthule.
Inqubo yokukhiqiza enembayo ephezulu kakhulu enelungelo lobunikazi.
-Okwakhelwe ngaphakathi okugcwele ukuqapha okuhlakaniphile nokuvikela okuhlanganisa ukuqapha izinga lokushisa kwemoto eshisayo, ukuqapha ukulandelana kwesigaba, ukuvala ukusetha kabusha ngesandla, inzwa yokushisa kawoyela.
-Ibanga elibanzi lesiqandisi ongakhetha kulo, kuhlanganisa no-R134A, R407c kanye no-R22(R404A, R507c uma ucelwa).

I-Microprogramming Control System
-Industrial PLC yokulawula okumaphakathi okuhlanganiswe nohlelo lokulawula umthamo we-compressor, qapha kahle.
-Ukuvikelwa okuhlanganisiwe kokushisa okuphansi, ukucindezela okuphezulu / okuphansi, ukulwa nokuqandisa, isigaba esingekho, i-anti-phase, i-overload, i-motor over temperature, umehluko kawoyela, ukushintshwa kokugeleza, ukuqala ukubambezeleka.
-Ulimi lokusebenza ongakukhetha, imenyu eholayo, isimo seyunithi esisebenza kalula ukusilungisa.


Ukufakwa Okulula, Ukugijima Okuthembekile
-Ukuqalisa okunezinyathelo eziseduze, kunciphisa umthelela kugesi.
Ukusebenza okuzinzile nokuphephile, ukudlidliza okuphansi, kulula ukufakwa.
-Isakhiwo esihlangene, isidingo sesikhala esincane nesisindo esilula, kulula ukuthutha nokufaka.
-Kufakwe izintambo ngokuphelele, kwahlolwa futhi kwahlolwa ukulethwa kwangaphambilini, konga isikhathi sokufaka nezindleko.
·Igobolondo neshubhu evaporator kanye ne-condenser, ishubhu lekhopha elibomvu elinentambo esebenza kahle kakhulu (ushintsho olubalulekile uma ucelwa).

·Isilawuli se-Siemens PLC, isixhumi esibonakalayo sesikrini sokuthinta i-LCD, ukusebenza okulula, umklamo ojwayelekile ukhokhisiwe.Izingxenye zikagesi ze-Schneider.

·R22,CFC Mahhala R407C,R134A ongakhetha kukho.

·380V-415V/50HZ3PH yokuklama okujwayelekile, iyunithi ye-Chiller inganikezwa ngokuya ngezidingo ezahlukahlukene.

·Kudingeka indawo encane yokufaka, asikho isidingo sokungena komoya.

I-HTS-W 1
I-HTS-W 2

 

Ukuvikelwa Kweyunithi Yokuphepha

 

- Ukuvikelwa kwangaphakathi kwe-Compressor,

-ngaphezu kokuvikelwa kwamanje

-ukuvikelwa kwengcindezi ephezulu/ephansi

-over ukuvikelwa lokushisa

-I-alamu yokushisa yokukhishwa okuphezulu

-ukuvikelwa kwesilinganiso sokugeleza

-isigaba sokulandelana/isigaba sishoda isivikelo

-Izinga eliphansi lokuvikelwa kokupholisa

-anti isivikelo sokuqandisa

-khipha ukuvikela ukushisa ngokweqile

 

Isevisi ephelele

-Ithimba Lezinqubo: Ithimba Lonjiniyela elinesipiliyoni seminyaka engu-15 esiqandisini sezimboni, ithimba labadayisi elinesipiliyoni seminyaka engu-7, Ithimba Lesevisi elinesipiliyoni seminyaka eyi-10.

-Isixazululo esenziwe ngokwezifiso sinikezwa njalo ngokuya ngezidingo.

-3 izinyathelo zokulawula ikhwalithi: ukulawulwa kwekhwalithi okungenayo, ukulawulwa kwekhwalithi yenqubo, ukulawulwa kwekhwalithi okuphumayo.

Isiqinisekiso sezinyanga eziyi-12 sayo yonke imikhiqizo.Ngaphakathi kwewaranti, noma iyiphi inkinga ebangelwa ukukhubazeka kwe-chiller ngokwayo, isevisi enikezwayo kuze kube yilapho inkinga ixazululiwe.

 

Izinzuzo ezinhlanu ze-HERO-TECH

 

•Amandla omkhiqizo:Singabahlinzeki abaqeqeshiwe nabaphezulu be-industrial chiller abaneminyaka engu-20 yesipiliyoni.

•Isiqondiso Somsebenzi:Isevisi yochwepheshe nabanolwazi & nethimba labadayisi emakethe yaphesheya kwezilwandle, enikeza isixazululo esisebenzayo ngokuya ngezidingo.

•Ukulethwa okusheshayo:I-1/2hp ukuya ku-50hp ama-chiller apholile esitokweni ukuze alethwe ngokushesha.

•Izinduku ezizinzile :Izinduku ezizinzile zingaqinisekisa ukukhiqiza okuzinzile kanye nekhwalithi ephezulu.Ukuqinisekisa isevisi yekhwalithi ephezulu kanye nokusekelwa okuphumelelayo emva kokuthengisa.

•Isevisi yegolide :Impendulo yekholi yesevisi phakathi nehora elingu-1, isixazululo sinikezwa phakathi namahora angu-4, kanye nethimba eliphethe ukufakwa nokunakekela phesheya kwezilwandle.

 

UMBONISO WEQHAWE LOBUCHWEPHESHE

 Umbukiso


  • Okwedlule:
  • Olandelayo:


  • 100ton amanzi apholise isikulufa chiller

    I-HTS-150WI-150TON yamanzi epholile i-screw chillermmexport1611035425990D05A9278

    I-screw chiller yamanzi epholile nge-compressor eyodwa

    Ukupholisa amandla kusuka ku-30ton kuya ku-300ton

    Imodeli: HTS-40W ~ HTS-100W

    Imodeli(HTS-***)

    40W

    50W

    60W

    75W

    85W

    100W

    Amandla okupholisa okuzisholo

    7℃

    Kcal/h

    108962

    143018

    153682

    205540

    242176

    284918

    kw

    126.7

    166.3

    178.7

    239.0

    281.6

    331.1

    12℃

    Kcal/h

    130118

    170796

    183524

    245444

    289218

    340302

    kw

    151.3

    198.6

    213.4

    285.4

    336.3

    395.7

    Amandla okokufaka

    kw

    28

    34.8

    38.5

    50.3

    56.7

    66.6

    Umthombo wamandla

    3PH 380V~415V 50HZ/ 220V~600V 60HZ

    Isiqandisi

    Uhlobo

    R22/R407C

    Shaja

    kg

    22

    27

    33

    42

    48

    55

    Lawula

    I-valve yokwandisa i-Thermostatic

    I-Compressor

    Uhlobo

    Isikulufu se-semi-hermermetic

    amandla

    kw

    28

    34.8

    38.5

    50.3

    56.7

    66.6

    Imodi yokuqala

    Y-△

    Ukulawula amandla

    0-25-50-75-100

    I-Evaporator

    Uhlobo

    Igobolondo neshubhu(i-ss plate heat exchanger)

    Umthamo wamanzi apholile

    m³/h

    20.5

    26.1

    29.5

    39.5

    45.6

    49.7

    Umfutho wamanzi wehla

    kPa

    32

    35

    38

    42

    42

    45

    Ukuxhumeka kwepayipi

    intshi

    3

    3

    3

    3

    3

    4

    I-Condenser

    Uhlobo

    Igobolondo neshubhu

    Umthamo wamanzi apholile

    m³/h

    25

    32.3

    36.6

    49.2

    56

    61.7

    Umfutho wamanzi wehla

    kPa

    42

    42

    43

    43

    43

    45

    Ukuxhumeka kwepayipi

    intshi

    3

    3

    3

    3

    3

    4

    Amadivayisi okuphepha

    Ukuvikela kwangaphakathi kwe-Compressor, ngaphezu kokuvikela kwamanje, ukuvikelwa kwengcindezi ephezulu/ephansi, ukuvikela okungaphezu kwezinga lokushisa, ukuvikelwa kwezinga lokugeleza, ukulandelana kwesigaba/isigaba esishodayo, isivikelo sokupholisa esisezingeni eliphansi, isivikelo sokuqanda, isivikelo sokushisa ngokweqile

    Ubukhulu

    Ubude

    mm

    2500

    2550

    2600

    2800

    2800

    2900

    Ububanzi

    mm

    780

    780

    780

    950

    950

    950

    Ubude

    mm

    1650

    1650

    1650

    1800

    1950

    1950

    Isisindo sengqikithi

    kg

    900

    1050

    1200

    1800

    1900

    2050

    Isisindo sokugijima

    kg

    1050

    1200

    1350

    1980

    2150

    2250

    Ukucaciswa okungenhla kuhambisana nemibandela yokuklama elandelayo:

    1. Izinga lokushisa lamanzi ashisayo abandayo ngu-12℃/7℃
    2. Izinga lokushisa lomoya lokupholisa le-inlet/outlet ngu-30℃/38℃
    3. Igesi engu-R134A ongakhetha kukho
    4. VFD chiller ongakhetha kukho

    Sinelungelo lokushintsha imininingwane ngaphandle kwesaziso esengeziwe.

     

    I-HTS120W~270W

     

    Imodeli(HTS-***)

    120W

    150W

    180W

    200W

    240W

    270W

    Amandla okupholisa okuzisholo

    7℃

    Kcal/h

    333680

    423550

    510926

    605526

    718616

    794984

    kw

    388.0

    492.5

    594.1

    704.1

    835.6

    924.4

    12℃

    Kcal/h

    398438

    505852

    610170

    723174

    858194

    949354

    kw

    463.3

    588.2

    709.5

    840.9

    997.9

    1103.9

    Amandla okokufaka

    kw

    79.6

    98.6

    120.4

    140.1

    166.8

    184.7

    Umthombo wamandla

    3PH 380V~415V 50HZ/ 220V~600V 60HZ

    Isiqandisi

    Uhlobo

    R22/R407C

    Shaja

    kg

    68

    88

    110

    121

    143

    165

    Lawula

    I-valve yokwandisa i-Thermostatic

    I-Compressor

    Uhlobo

    Isikulufu se-semihermetic

    amandla

    kw

    79.6

    98.6

    120.4

    140.1

    166.8

    184.7

    Imodi yokuqala

    Y-△

    Ukulawula amandla

    0-25-50-75-100

    I-Evaporator

    Uhlobo

    Igobolondo neshubhu(i-ss plate heat exchanger)

    Umthamo wamanzi apholile

    m³/h

    62.4

    81

    98

    115

    135.7

    153

    Umfutho wamanzi wehla

    kPa

    40

    43

    45

    45

    43

    47

    Ukuxhumeka kwepayipi

    intshi

    4

    5

    6

    6

    6

    6

    I-Condenser

    Uhlobo

    Igobolondo neshubhu

    Umthamo wamanzi apholile

    m³/h

    77

    101

    125

    125

    170

    191

    Umfutho wamanzi wehla

    kPa

    48

    46

    48

    48

    45

    47

    Ukuxhumeka kwepayipi

    intshi

    4

    3*2

    3*2

    4*2

    4*2

    4*2

    Amadivayisi okuphepha

    Ukuvikela kwangaphakathi kwe-Compressor, ngaphezu kokuvikela kwamanje, ukuvikelwa kwengcindezi ephezulu/ephansi, ukuvikela okungaphezu kwezinga lokushisa, ukuvikelwa kwezinga lokugeleza, ukulandelana kwesigaba/isigaba esishodayo, isivikelo sokupholisa esisezingeni eliphansi, isivikelo sokuqanda, isivikelo sokushisa ngokweqile

    Ubukhulu Ubude

    mm

    3000

    3300

    3800

    3900

    4300

    4500

    Ububanzi

    mm

    1200

    1380

    1380

    1380

    1480

    1480

    Ubude

    mm

    1580

    1630

    1750

    1750

    1780

    1780

    Isisindo sengqikithi

    kg

    2500

    2650

    3150

    3350

    3850

    4160

    Isisindo sokugijima

    kg

    2700

    2900

    3400

    3650

    4150

    4460

    Ukucaciswa okungenhla kuhambisana nemibandela yokuklama elandelayo:

    1. Izinga lokushisa lamanzi ashisayo abandayo ngu-12℃/7℃
    2. Izinga lokushisa lomoya lokupholisa le-inlet/outlet ngu-30℃/38℃
    3. Igesi engu-R134A ongakhetha kukho
    4. VFD chiller ongakhetha kukho

    Sinelungelo lokushintsha imininingwane ngaphandle kwesaziso esengeziwe.

     

    Amanzi apholile ama-Screw chiller anama-Double compressors

    HTS-100WD ~ HTS-300WD

    Imodeli(HTS-***)

    100WD

    120WD

    150WD

    180WD

    200WD

    240W

    280W

    300WD

    Amandla okupholisa okuzisholo

    7℃

    Kcal/h

    286036

    307364

    411080

    511872

    569836

    667360

    794468

    847100

    kw

    332.6

    357.4

    478.0

    595.2

    662.6

    776.0

    923.8

    985.0

    12℃

    Kcal/h

    341592

    367048

    490888

    611288

    680604

    796876

    948924

    1011704

    kw

    397.2

    426.8

    570.8

    710.8

    791.4

    926.6

    1103.4

    1176.4

    Amandla okokufaka

    kw

    69.6

    77

    100.6

    123.4

    133.2

    159.2

    183.8

    197.2

    Umthombo wamandla

    3PH 380V~415V 50HZ/ 220V~600V 60HZ

    Isiqandisi

    Uhlobo

    R22/C407C

    Shaja

    kg

    27*2

    33*2

    42*2

    48*2

    55*2

    68*2

    77*2

    88*2

    Lawula

    I-valve yokwandisa i-Thermostatic

    I-Compressor

    Uhlobo

    Isikulufu se-semihermetic

    Amandla

    kw

    34.8*2

    38.5*2

    50.3*2

    61.7*2

    66.6*2

    79.6*2

    91.9*2

    98.6*2

    Imodi yokuqala

    Y-△

    Ukulawula amandla

    0-25-50-75-100

    I-Evaporator

    Uhlobo

    Igobolondo neshubhu

    Umthamo wamanzi apholile

    m³/h

    52.2

    59

    79

    91.2

    99.4

    124.8

    151.6

    162

    Umfutho wamanzi wehla

    kPa

    42

    42

    46

    43

    45

    45

    43

    48

    Ukuxhumeka kwepayipi

    intshi

    4

    4

    5

    6

    6

    6

    6

    8

    I-Condenser

    Uhlobo

    Umthamo wamanzi apholile

    m³/h

    64.6

    73.2

    98.4

    112

    123.4

    154

    191

    202

    Umfutho wamanzi wehla

    kPa

    41

    42

    42

    45

    48

    46

    48

    48

    Ukuxhumeka kwepayipi

    intshi

    4

    4

    3*2

    3*2

    4*2

    4*2

    4*2

    5*2

    Amadivayisi okuphepha

    Ukuvikela kwangaphakathi kwe-Compressor, ngaphezu kokuvikela kwamanje, ukuvikelwa kwengcindezi ephezulu/ephansi, ukuvikela okungaphezu kwezinga lokushisa, ukuvikelwa kwezinga lokugeleza, ukulandelana kwesigaba/isigaba esishodayo, isivikelo sokupholisa esisezingeni eliphansi, isivikelo sokuqanda, isivikelo sokushisa ngokweqile

    Ubukhulu Ubude

    mm

    2800

    2950

    3150

    3480

    3480

    3650

    3650

    3750

    Ububanzi

    mm

    780

    810

    850

    875

    895

    1120

    1220

    1300

    Ubude

    mm

    1650

    1650

    1750

    1850

    1850

    1950

    1950

    2100

    Isisindo sengqikithi

    kg

    1850

    2200

    2650

    2800

    3450

    3950

    4100

    4450

    Isisindo sokugijima

    kg

    2150

    2500

    2970

    3400

    4160

    4350

    4700

    5050

    Ukucaciswa okungenhla kuhambisana nemibandela yokuklama elandelayo:

    1. Izinga lokushisa lamanzi ashisayo abandayo ngu-12℃/7℃
    2. Izinga lokushisa lomoya lokupholisa le-inlet/outlet ngu-30℃/38℃
    3. Igesi engu-R134A ongakhetha kukho
    4. VFD chiller ongakhetha kukho

    Sinelungelo lokushintsha imininingwane ngaphandle kwesaziso esengeziwe.

     

    HTS-360WD ~ HTS-540WD

    Imodeli(HTS-***)

    360WD

    400WD

    460WD

    480WD

    540WD

    Amandla okupholisa okuzisholo

    7℃

    Kcal/h

    1021852

    1211052

    1320616

    1437232

    1589968

    kw

    1188.2

    1408.2

    1535.6

    1671.2

    1848.8

    12℃

    Kcal/h

    1220340

    1446348

    1577068

    1681988

    1898708

    kw

    1419.0

    1681.8

    1833.8

    1955.8

    2207.8

    Amandla okokufaka

    kw

    240.8

    280.2

    314

    333.6

    369.4

    Umthombo wamandla

    3PH 380V~415V 50HZ/60HZ

    Isiqandisi

    Uhlobo

    R22

    Shaja

    kg

    110*2

    121*2

    132*2

    143*2

    165*2

    Lawula

    I-valve yokwandisa i-Thermostatic

    I-Compressor

    Uhlobo

    Isikulufu se-semihermetic

    Amandla

    kw

    120*2

    140*2

    157*2

    167*2

    185*2

    Imodi yokuqala

    Y-△

    Ukulawula amandla

    0-25-50-75-100

    I-Evaporator

    Uhlobo

    Igobolondo neshubhu

    Umthamo wamanzi apholile

    m³/h

    169

    231.4

    254

    271.4

    306

    Umfutho wamanzi wehla

    kPa

    44

    45

    42

    45

    46

    Ukuxhumeka kwepayipi

    intshi

    8

    8

    10

    10

    10

    I-Condenser

    Uhlobo

    Igobolondo neshubhu

    Umthamo wamanzi apholile

    m³/h

    248

    290

    318

    340

    382

    Umfutho wamanzi wehla

    kPa

    46

    42

    48

    48

    48

    Ukuxhumeka kwepayipi

    intshi

    5*2

    5*2

    5*2

    6*2

    6*2

    Amadivayisi okuphepha

    Ukuvikela kwangaphakathi kwe-Compressor, ngaphezu kokuvikela kwamanje, ukuvikelwa kwengcindezi ephezulu/ephansi, ukuvikela okungaphezu kwezinga lokushisa, ukuvikelwa kwezinga lokugeleza, ukulandelana kwesigaba/isigaba esishodayo, isivikelo sokupholisa esisezingeni eliphansi, isivikelo sokuqanda, isivikelo sokushisa ngokweqile

    Ubukhulu Ubude

    mm

    4230

    4230

    4350

    4350

    4420

    Ububanzi

    mm

    1380

    1480

    1450

    1560

    1650

    Ubude

    mm

    2150

    2250

    2250

    2300

    2450

    Isisindo sengqikithi

    kg

    5000

    5250

    5500

    5750

    6000

    Isisindo sokugijima

    kg

    5700

    5950

    6100

    6350

    6600

    Ukucaciswa okungenhla kuhambisana nemibandela yokuklama elandelayo:

    1. Izinga lokushisa lamanzi ashisayo abandayo ngu-12℃/7℃
    2. Izinga lokushisa lomoya lokupholisa le-inlet/outlet ngu-30℃/38℃
    3. Igesi engu-R134A ongakhetha kukho
    4. VFD chiller ongakhetha kukho

    Sinelungelo lokushintsha imininingwane ngaphandle kwesaziso esengeziwe.

     

    Ama-compressor amane

    HTS-300WF ~ HTS-1080WF

    Imodeli(HTS-***)

    300WF

    340WF

    400WF

    480WF

    600WF

    680WF

    800WF

    920WF

    950WF

    1080WF

    Amandla okupholisa okuzisholo

    7℃

    Kcal/h

    822160

    968704

    1139672

    1334720

    1694200

    1997608

    2422104

    2641232

    2874120

    3179936

    kw

    956.0

    1126.4

    1325.2

    1552.0

    1970.0

    2322.8

    2816.4

    3071.2

    3342.0

    3697.6

    ithani

    271

    320

    376

    441

    560

    660

    800

    873

    950

    1051

    12℃

    Kcal/h

    981776

    1156872

    1361208

    1593752

    2023408

    2385640

    2892696

    3154136

    3363976

    3797416

    kw

    1141.6

    1345.2

    1582.8

    1853.2

    2352.8

    2774.0

    3363.6

    3667.6

    3911.6

    4415.6

    ithani

    324

    382

    450

    526

    668

    788

    956

    1042

    1112

    1255

    Amandla okokufaka

    kw

    201

    226

    266

    318

    394

    466

    560

    628

    666

    738

    Umthombo wamandla

    3PH 380V~415V 50HZ/ 220V~600V 60HZ

    Isiqandisi Uhlobo

    R22/R407C

    Shaja

    kg

    42*4

    48*4

    55*4

    68*4

    88*4

    108*4

    121*4

    132*4

    143*4

    165*4

    Lawula

    I-valve yokwandisa i-Thermostatic

    I-Compressor Uhlobo

    Isikulufu se-semihermetic

    Amandla

    kw

    50*4

    56.5*4

    66.5*4

    79.5*4

    98.5*4

    116*4

    140*4

    157*4

    166*4

    184*4

    Imodi yokuqala

    Y-△

    Ukulawula amandla

    0-25-50-75-100

    I-Evaporator

    Uhlobo

    Igobolondo neshubhu

    Umthamo wamanzi apholile

    m³/h

    158

    182.4

    198.8

    249.6

    324

    382.8

    462.8

    508

    542.8

    612

    Umfutho wamanzi wehla

    kPa

    46

    43

    45

    45

    48

    43

    45

    42

    45

    46

    Ukuxhumeka kwepayipi

    intshi

    8*2

    8*2

    10*2

    10*2

    10*2

    10*2

    12*2

    12*2

    8*4

    8*4

    I-Condenser

    Uhlobo

    Igobolondo neshubhu

    Ukupholisa ukugeleza kwamanzi

    m³/h

    196.8

    224

    246.8

    308

    404

    476

    580

    636

    680

    764

    Umfutho wamanzi wehla

    kPa

    42

    45

    48

    46

    48

    45

    42

    48

    48

    48

    Ukuxhumeka kwepayipi

    intshi

    6*2

    6*2

    8*2

    8*2

    8*2

    4*4

    4*4

    6*4

    6*4

    6*4

    Amadivayisi okuphepha

    Ukuvikela kwangaphakathi kwe-Compressor, ngaphezu kokuvikela kwamanje, ukuvikelwa kwengcindezi ephezulu/ephansi, ukuvikela okungaphezu kwezinga lokushisa, ukuvikelwa kwezinga lokugeleza, ukulandelana kwesigaba/isigaba esishodayo, isivikelo sokupholisa esisezingeni eliphansi, isivikelo sokuqanda, isivikelo sokushisa ngokweqile

    Ubukhulu Ubude

    mm

    3150

    3480

    3480

    3650

    3750

    3750

    4230

    4350

    4350

    4420

    Ububanzi

    mm

    1700

    1750

    1790

    2240

    2600

    2900

    2960

    2900

    3300

    3300

    Ubude

    mm

    1750

    1850

    1850

    1950

    2100

    2150

    2250

    2250

    2300

    2450

    Isisindo sengqikithi

    kg

    2650

    2800

    3450

    3950

    4450

    4700

    5250

    5500

    5750

    6000

    Isisindo sokugijima

    kg

    3200

    3380

    4160

    4760

    5270

    5460

    6100

    6400

    6680

    6970

    Ukucaciswa okungenhla kuhambisana nemibandela yokuklama elandelayo:

    1. Izinga lokushisa lamanzi ashisayo abandayo ngu-12℃/7℃
    2. Izinga lokushisa lomoya lokupholisa le-inlet/outlet ngu-30℃/38℃
    3. Igesi engu-R134A ongakhetha kukho
    4. VFD chiller ongakhetha kukho

    Sinelungelo lokushintsha imininingwane ngaphandle kwesaziso esengeziwe.

     

    Ukupakisha ukuthunyelwa

    isitifiketi

    Q1: Ungakwazi yini ukusisiza ukuthi sincome imodeli yephrojekthi yethu?
    A1: Yebo, sinonjiniyela wokubheka imininingwane bese sikukhethela imodeli elungile.Ngokusekelwe kokulandelayo:
    1) Amandla okupholisa;
    2) Uma ungazi, unganikeza izinga lokugeleza emshinini wakho, izinga lokushisa ngaphakathi namazinga okushisa aphume engxenyeni yakho oyisebenzisayo;
    3) Ukushisa kwemvelo;
    4) Uhlobo lwesiqandisi, R22, R407c noma okunye, pls ucacise;
    5) Amandla kagesi;
    6) Imboni yezicelo;
    7) Ukugeleza kwepompo kanye nezidingo zokucindezela;
    8) Noma yiziphi ezinye izidingo ezikhethekile.

     

     

    Q2: Ungawuqinisekisa kanjani umkhiqizo wakho ngekhwalithi enhle?
    A2: Yonke imikhiqizo yethu enesitifiketi se-CE kanye nenkampani yethu Ihambisana ngokuqinile nohlelo lokuphatha ikhwalithi ye-ISO900.Sisebenzisa izinsiza zomkhiqizo ezidumile emhlabeni wonke, njenge-DANFOSS, i-COPELAND, i-SANYO, i-BITZER, i-HANBELL compressors, izakhi zikagesi ze-Schneider, i-DANFOSS/EMERSON izingxenye zesiqandisi.
    Amayunithi azohlolwa ngokugcwele ngaphambi kwephakheji futhi Ukupakishwa kuzobhekwa ngokucophelela.

     

     

    Q3: Iyini iwaranti?
    I-A3: Iwaranti yonyaka ongu-1 yazo zonke izingxenye;Impilo yakho yonke awusebenzi!

     

     

    Q4: Ingabe ungumkhiqizi?
    A4: Yebo, sineminyaka engaphezu kwama-23 ebhizinisini leziqandisi zezimboni.Ifektri yethu etholakala e-Shenzhen;Siyakwamukela ukusivakashela noma nini.Futhi ube ne-patent ekwakhiweni kwama-chillers.

     

     

    Q5: Ngingalifaka kanjani i-oda?
    A5: Send us enquiry via email: sales@szhero-tech.com, call us via Cel number +86 15920056387 directly.