HTS-W jerin masana'antu chiller an fi amfani dashi a cikin masana'antar filastik & Rubber;Yana iya sarrafa daidaitaccen zafin jiki na gyare-gyare kuma ya rage sake zagayowar gyare-gyare, ƙara ingancin samfurin da haɓaka haɓakar samarwa.Har ila yau, ana amfani da su sosai a aikin Metal, Mechanical & Engineering, Chemical & Pharmaceutical, Abinci & Abin sha, Laser, Electronics Industry, Textile, Electroplate, Semi-conductor test, Water jet, Vacuum shafi, Gina da Soja.
Aikace-aikace
HERO-TECH chillers suna isar da ƙima zuwa aikace-aikace iri-iri tare da ingantattun zaɓuɓɓukan ƙarfin kuzari.
Matsakaici da babban sikelin sanyaya masana'antu
Tsarin kwandishan na tsakiya
Dakin sanyi, ɗakin zafi mai zafi
Siffofin ƙira
Sanannen Brand Compressor
-Unit ta ɗauki Jamus BITZER ko Taiwan HANBELL alama Semi-hermetic dunƙule kwampreso.Sabbin 5 zuwa 6 ƙwararrun bayanan martaba na dunƙulewa tare da ingantaccen inganci.
-4 iko iko iko, 25% -50% -75% -100%.
-Madaidaitacce mara iyaka ko madaidaicin iko iko, fasalulluka ingantaccen kuzari, tsayayye da gudu shuru.
Mafi ci-gaba ƙwararren ƙwaƙƙwaran tsari na ƙera madaidaici.
-Cikakken ingantaccen saka idanu da kariya gami da sa ido kan zafin jiki na zafin jiki, sa ido kan tsarin lokaci, sake saitin kullewa da hannu, firikwensin zafin mai.
-Mai faɗin firiji don zaɓi, gami da R134A, R407c da R22 (R404A, R507c akan buƙata).
Microprogramming Control System
-Industrial PLC tsakiya sarrafawa hade tare da kwampreso ikon sarrafa tsarin, daidai saka idanu.
-Harfafa kariya don ƙananan zafin jiki, babban / matsa lamba, anti-daskarewa, lokaci bace, anti-lokaci, overloading, motor a kan zafin jiki, mai banbanta mai, kwarara sauya, fara latency.
-Yaren aiki na zaɓi, jagoran menu, yanayin yanki mai sauƙin daidaitawa.
Sauƙin Shigarwa, Amintaccen Gudu
-Farawa a kusa, rage tasirin wutar lantarki.
Tsayayye kuma mai aminci yana gudana, ƙananan girgiza, mai sauƙi don shigarwa.
- Tsarin tsari, ƙarancin buƙatun sararin samaniya da haske a cikin nauyi, mai sauƙi don sufuri da shigarwa.
- Cikakken waya, dubawa da gwadawa kafin isarwa, adana lokacin shigarwa da farashi.
Shell da tube evaporator da condenser, high m thread ja jan jan tube (material canji a kan bukatar).
Siemens PLC iko, LCD touch allon dubawa, sauki aiki, misali zane caje.Abubuwan lantarki na Schneider.
R22,CFC Kyauta R407C,R134A don zaɓi.
· 380V-415V / 50HZ3PH don daidaitaccen ƙira, ana iya ba da sashin Chiller bisa ga buƙatu daban-daban.
Ana buƙatar ƙananan wurin shigarwa, babu buƙatar samun iska.
Kariyar Tsaron Sashen
- Kariyar ciki,
-kan kariya na yanzu
- high / low matsa lamba kariya
-over zafin jiki kariya
- Ƙararrawa zazzabi mai girma
-kare yawan kwarara
-lokacin tsari/lokaci bata kariya
- low matakin coolant kariya
-kariyar daskarewa
-kare zafi mai zafi
M sabis
-Tungiyar Gudanarwa: Ƙungiyar injiniya tare da matsakaicin shekaru 15 na gwaninta a cikin firiji na masana'antu, ƙungiyar tallace-tallace tare da matsakaicin shekaru 7 na gwaninta, Ƙungiyar sabis tare da matsakaicin shekaru 10 na gwaninta.
- Magani na musamman koyaushe ana samarwa bisa ga buƙatu.
-3 matakai kula da ingancin: mai shigowa ingancin iko, tsari ingancin iko, fita ingancin iko.
- garanti na watanni 12 ga duk samfuran.A cikin garanti, kowace matsala ta haifar da lahani na chiller kanta, sabis wanda ake bayarwa har sai an warware matsalar.
Fa'idodi guda biyar na HERO-TECH
• Ƙarfin alama:Mu ne ƙwararrun kuma manyan masu samar da chiller masana'antu tare da ƙwarewar shekaru 20.
Jagorar Ƙwararru:ƙwararrun ƙwararrun ƙwararrun ƙwararrun ƙwararru & sabis na ƙungiyar tallace-tallace zuwa kasuwar ketare, suna ba da mafita na ƙwararru bisa ga buƙatu.
•Aiki da sauri:1/2hp zuwa 50hp chillers masu sanyaya iska a cikin hannun jari don bayarwa nan da nan.
• Ma'aikata masu ƙarfi:Ma'aikata masu tsattsauran ra'ayi na iya tabbatar da ingantaccen aiki mai inganci.Don tabbatar da sabis mai inganci da ingantaccen goyon bayan tallace-tallace.
•Sabis na Zinariya:Amsar kiran sabis a cikin awa 1, bayani da aka bayar a cikin sa'o'i 4, da ƙungiyar shigarwa da kulawa ta ketare.
NUNA JARUMI-TECH
Ruwa mai sanyaya screw chiller tare da kwampreso guda ɗaya
Cooling iya aiki daga 30ton zuwa 300ton
Samfura: HTS-40W ~ HTS-100W
Model (HTS-***) | 40W | 50W | 60W | 75W | 85W | 100W | ||
Ƙarfin sanyaya mara kyau | 7 ℃ | Kcal/h | 108962 | 143018 | 153682 | 205540 | 242176 | 284918 |
kw | 126.7 | 166.3 | 178.7 | 239.0 | 281.6 | 331.1 | ||
12 ℃ | Kcal/h | 130118 | 170796 | 183524 | 245444 | 289218 | Farashin 340302 | |
kw | 151.3 | 198.6 | 213.4 | 285.4 | 336.3 | 395.7 | ||
Ƙarfin shigarwa | kw | 28 | 34.8 | 38.5 | 50.3 | 56.7 | 66.6 | |
Tushen wuta | 3PH 380V ~ 415V 50HZ/220V ~ 600V 60HZ | |||||||
Mai firiji | Nau'in | R22/R407C | ||||||
Caji | kg | 22 | 27 | 33 | 42 | 48 | 55 | |
Sarrafa | Thermostatic fadada bawul | |||||||
Compressor | Nau'in | Semi-hermermetic dunƙule | ||||||
iko | kw | 28 | 34.8 | 38.5 | 50.3 | 56.7 | 66.6 | |
Yanayin farawa | Y-△ | |||||||
Ikon iko | ) | 0-25-50-75-100 | ||||||
Evaporator | Nau'in | Shell da tube (ss farantin zafi Exchanger) | ||||||
Ƙarar ruwan sanyi | m³/h | 20.5 | 26.1 | 29.5 | 39.5 | 45.6 | 49.7 | |
Matsalolin ruwa | kPa | 32 | 35 | 38 | 42 | 42 | 45 | |
Haɗin bututu | inci | 3 | 3 | 3 | 3 | 3 | 4 | |
Condenser | Nau'in | Shell da tube | ||||||
Ƙarar ruwan sanyi | m³/h | 25 | 32.3 | 36.6 | 49.2 | 56 | 61.7 | |
Matsalolin ruwa | kPa | 42 | 42 | 43 | 43 | 43 | 45 | |
Haɗin bututu | inci | 3 | 3 | 3 | 3 | 3 | 4 | |
Na'urorin tsaro | Kariyar ciki ta kwampreso, akan kariya ta yanzu, babban kariya / ƙarancin matsa lamba, kan kariyar zafin jiki, kariyar ƙimar kwarara, tsarin lokaci/ɓataccen kariya, ƙarancin yanayin sanyaya, kariya ta daskarewa, kariyar daskarewa. | |||||||
Girma | Tsawon | mm | 2500 | 2550 | 2600 | 2800 | 2800 | 2900 |
Nisa | mm | 780 | 780 | 780 | 950 | 950 | 950 | |
Tsayi | mm | 1650 | 1650 | 1650 | 1800 | 1950 | 1950 | |
Cikakken nauyi | kg | 900 | 1050 | 1200 | 1800 | 1900 | 2050 | |
Gudun nauyi | kg | 1050 | 1200 | 1350 | 1980 | 2150 | 2250 | |
Ƙididdigar da ke sama sun dogara da yanayin ƙira masu zuwa:
Mun tanadi haƙƙin gyara ƙayyadaddun bayanai ba tare da ƙarin sanarwa ba. |
Saukewa: HTS120W-270W
Model (HTS-***) | 120W | 150W | 180W | 200W | 240W | 270W | ||
Ƙarfin sanyaya mara kyau | 7 ℃ | Kcal/h | 333680 | 423550 | 510926 | 605526 | 718616 | 794984 |
kw | 388.0 | 492.5 | 594.1 | 704.1 | 835.6 | 924.4 | ||
12 ℃ | Kcal/h | 398438 | 505852 | 610170 | 723174 | 858194 | 949354 | |
kw | 463.3 | 588.2 | 709.5 | 840.9 | 997.9 | 1103.9 | ||
Ƙarfin shigarwa | kw | 79.6 | 98.6 | 120.4 | 140.1 | 166.8 | 184.7 | |
Tushen wuta | 3PH 380V ~ 415V 50HZ/220V ~ 600V 60HZ | |||||||
Mai firiji | Nau'in | R22/R407C | ||||||
Caji | kg | 68 | 88 | 110 | 121 | 143 | 165 | |
Sarrafa | Thermostatic fadada bawul | |||||||
Compressor | Nau'in | Semi-hermetic dunƙule | ||||||
iko | kw | 79.6 | 98.6 | 120.4 | 140.1 | 166.8 | 184.7 | |
Yanayin farawa | Y-△ | |||||||
Ikon iko | ) | 0-25-50-75-100 | ||||||
Evaporator | Nau'in | Shell da tube (ss farantin zafi Exchanger) | ||||||
Ƙarar ruwan sanyi | m³/h | 62.4 | 81 | 98 | 115 | 135.7 | 153 | |
Matsalolin ruwa | kPa | 40 | 43 | 45 | 45 | 43 | 47 | |
Haɗin bututu | inci | 4 | 5 | 6 | 6 | 6 | 6 | |
Condenser | Nau'in | Shell da tube | ||||||
Ƙarar ruwan sanyi | m³/h | 77 | 101 | 125 | 125 | 170 | 191 | |
Matsalolin ruwa | kPa | 48 | 46 | 48 | 48 | 45 | 47 | |
Haɗin bututu | inci | 4 | 3*2 | 3*2 | 4*2 | 4*2 | 4*2 | |
Na'urorin tsaro | Kariyar ciki ta kwampreso, akan kariya ta yanzu, babban kariya / ƙarancin matsa lamba, kan kariyar zafin jiki, kariyar ƙimar kwarara, tsarin lokaci/ɓataccen kariya, ƙarancin yanayin sanyaya, kariya ta daskarewa, kariyar daskarewa. | |||||||
Girma | Tsawon | mm | 3000 | 3300 | 3800 | 3900 | 4300 | 4500 |
Nisa | mm | 1200 | 1380 | 1380 | 1380 | 1480 | 1480 | |
Tsayi | mm | 1580 | 1630 | 1750 | 1750 | 1780 | 1780 | |
Cikakken nauyi | kg | 2500 | 2650 | 3150 | 3350 | 3850 | 4160 | |
Gudun nauyi | kg | 2700 | 2900 | 3400 | 3650 | 4150 | 4460 | |
Ƙididdigar da ke sama sun dogara da yanayin ƙira masu zuwa:
Mun tanadi haƙƙin gyara ƙayyadaddun bayanai ba tare da ƙarin sanarwa ba. |
Mai sanyaya ruwa Screw chillers tare da compressors Biyu
HTS-100WD ~ HTS-300WD
Model (HTS-***) | 100WD | 120WD | 150WD | 180WD | 200WD | 240W | 280W | 300WD | ||
Ƙarfin sanyaya mara kyau | 7 ℃ | Kcal/h | 286036 | 307364 | 411080 | 511872 | 569836 | 667360 | 794468 | 847100 |
kw | 332.6 | 357.4 | 478.0 | 595.2 | 662.6 | 776.0 | 923.8 | 985.0 | ||
12 ℃ | Kcal/h | 341592 | 367048 | 490888 | 611288 | 680604 | 796876 | 948924 | 1011704 | |
kw | 397.2 | 426.8 | 570.8 | 710.8 | 791.4 | 926.6 | 1103.4 | 1176.4 | ||
Ƙarfin shigarwa | kw | 69.6 | 77 | 100.6 | 123.4 | 133.2 | 159.2 | 183.8 | 197.2 | |
Tushen wuta | 3PH 380V ~ 415V 50HZ/220V ~ 600V 60HZ | |||||||||
Mai firiji | Nau'in | R22/C407C | ||||||||
Caji | kg | 27*2 | 33*2 | 42*2 | 48*2 | 55*2 | 68*2 | 77*2 | 88*2 | |
Sarrafa | Thermostatic fadada bawul | |||||||||
Compressor | Nau'in | Semi-hermetic dunƙule | ||||||||
Ƙarfi | kw | 34.8*2 | 38.5*2 | 50.3*2 | 61.7*2 | 66.6*2 | 79.6*2 | 91.9*2 | 98.6*2 | |
Yanayin farawa | Y-△ | |||||||||
Ikon iko | ) | 0-25-50-75-100 | ||||||||
Evaporator | Nau'in | Shell da tube | ||||||||
Ƙarar ruwan sanyi | m³/h | 52.2 | 59 | 79 | 91.2 | 99.4 | 124.8 | 151.6 | 162 | |
Matsalolin ruwa | kPa | 42 | 42 | 46 | 43 | 45 | 45 | 43 | 48 | |
Haɗin bututu | inci | 4 | 4 | 5 | 6 | 6 | 6 | 6 | 8 | |
Condenser | Nau'in | |||||||||
Ƙarar ruwan sanyi | m³/h | 64.6 | 73.2 | 98.4 | 112 | 123.4 | 154 | 191 | 202 | |
Matsalolin ruwa | kPa | 41 | 42 | 42 | 45 | 48 | 46 | 48 | 48 | |
Haɗin bututu | inci | 4 | 4 | 3*2 | 3*2 | 4*2 | 4*2 | 4*2 | 5*2 | |
Na'urorin tsaro | Kariyar ciki ta kwampreso, akan kariya ta yanzu, babban kariya / ƙarancin matsa lamba, kan kariyar zafin jiki, kariyar ƙimar kwarara, tsarin lokaci/ɓataccen kariya, ƙarancin yanayin sanyaya, kariya ta daskarewa, kariyar daskarewa. | |||||||||
Girma | Tsawon | mm | 2800 | 2950 | 3150 | 3480 | 3480 | 3650 | 3650 | 3750 |
Nisa | mm | 780 | 810 | 850 | 875 | 895 | 1120 | 1220 | 1300 | |
Tsayi | mm | 1650 | 1650 | 1750 | 1850 | 1850 | 1950 | 1950 | 2100 | |
Cikakken nauyi | kg | 1850 | 2200 | 2650 | 2800 | 3450 | 3950 | 4100 | 4450 | |
Gudun nauyi | kg | 2150 | 2500 | 2970 | 3400 | 4160 | 4350 | 4700 | 5050 | |
Ƙididdigar da ke sama sun dogara da yanayin ƙira masu zuwa:
Mun tanadi haƙƙin gyara ƙayyadaddun bayanai ba tare da ƙarin sanarwa ba. |
Saukewa: HTS-360WD-HTS-540WD
Model (HTS-***) | 360WD | 400WD | 460WD | 480WD | 540WD | ||
Ƙarfin sanyaya mara kyau | 7 ℃ | Kcal/h | 1021852 | Farashin 1211052 | 1320616 | 1437232 | 1589968 |
kw | 1188.2 | 1408.2 | 1535.6 | 1671.2 | 1848.8 | ||
12 ℃ | Kcal/h | Farashin 1220340 | 1446348 | 1577068 | 1681988 | 1898708 | |
kw | 1419.0 | 1681.8 | 1833.8 | 1955.8 | 2207.8 | ||
Ƙarfin shigarwa | kw | 240.8 | 280.2 | 314 | 333.6 | 369.4 | |
Tushen wuta | 3PH 380V ~ 415V 50HZ/60HZ | ||||||
Mai firiji | Nau'in | R22 | |||||
Caji | kg | 110*2 | 121*2 | 132*2 | 143*2 | 165*2 | |
Sarrafa | Thermostatic fadada bawul | ||||||
Compressor | Nau'in | Semi-hermetic dunƙule | |||||
Ƙarfi | kw | 120*2 | 140*2 | 157*2 | 167*2 | 185*2 | |
Yanayin farawa | Y-△ | ||||||
Ikon iko | ) | 0-25-50-75-100 | |||||
Evaporator | Nau'in | Shell da tube | |||||
Ƙarar ruwan sanyi | m³/h | 169 | 231.4 | 254 | 271.4 | 306 | |
Matsalolin ruwa | kPa | 44 | 45 | 42 | 45 | 46 | |
Haɗin bututu | inci | 8 | 8 | 10 | 10 | 10 | |
Condenser | Nau'in | Shell da tube | |||||
Ƙarar ruwan sanyi | m³/h | 248 | 290 | 318 | 340 | 382 | |
Matsalolin ruwa | kPa | 46 | 42 | 48 | 48 | 48 | |
Haɗin bututu | inci | 5*2 | 5*2 | 5*2 | 6*2 | 6*2 | |
Na'urorin tsaro | Kariyar ciki ta kwampreso, akan kariya ta yanzu, babban kariya / ƙarancin matsa lamba, kan kariyar zafin jiki, kariyar ƙimar kwarara, tsarin lokaci/ɓataccen kariya, ƙarancin yanayin sanyaya, kariya ta daskarewa, kariyar daskarewa. | ||||||
Girma | Tsawon | mm | 4230 | 4230 | 4350 | 4350 | 4420 |
Nisa | mm | 1380 | 1480 | 1450 | 1560 | 1650 | |
Tsayi | mm | 2150 | 2250 | 2250 | 2300 | 2450 | |
Cikakken nauyi | kg | 5000 | 5250 | 5500 | 5750 | 6000 | |
Gudun nauyi | kg | 5700 | 5950 | 6100 | 6350 | 6600 | |
Ƙididdigar da ke sama sun dogara da yanayin ƙira masu zuwa:
Mun tanadi haƙƙin gyara ƙayyadaddun bayanai ba tare da ƙarin sanarwa ba. |
Kwampressors guda hudu
Saukewa: HTS-300WF-1080WF
Model (HTS-***) | 300WF | 340WF | 400WF | 480WF | 600WF | 680WF | 800WF | 920WF | 950WF | 1080WF | ||
Ƙarfin sanyaya mara kyau | 7 ℃
| Kcal/h | 822160 | 968704 | 1139672 | 1334720 | 1694200 | 1997608 | 2422104 | 2641232 | 2874120 | 3179936 |
kw | 956.0 | 1126.4 | 1325.2 | 1552.0 | 1970.0 | 2322.8 | 2816.4 | 3071.2 | 3342.0 | 3697.6 | ||
ton | 271 | 320 | 376 | 441 | 560 | 660 | 800 | 873 | 950 | 1051 | ||
12 ℃ | Kcal/h | 981776 | 1156872 | 1361208 | 1593752 | 2023408 | 2385640 | 2892696 | 3154136 | 3363976 | 3797416 | |
kw | 1141.6 | 1345.2 | 1582.8 | 1853.2 | 2352.8 | 2774.0 | 3363.6 | 3667.6 | 3911.6 | 4415.6 | ||
ton | 324 | 382 | 450 | 526 | 668 | 788 | 956 | 1042 | 1112 | 1255 | ||
Ƙarfin shigarwa | kw | 201 | 226 | 266 | 318 | 394 | 466 | 560 | 628 | 666 | 738 | |
Tushen wuta | 3PH 380V ~ 415V 50HZ/220V ~ 600V 60HZ | |||||||||||
Firiji | Nau'in | R22/R407C | ||||||||||
Caji | kg | 42*4 | 48*4 | 55*4 | 68*4 | 88*4 | 108*4 | 121*4 | 132*4 | 143*4 | 165*4 | |
Sarrafa | Thermostatic fadada bawul | |||||||||||
Compressor | Nau'in | Semi-hermetic dunƙule | ||||||||||
Ƙarfi | kw | 50*4 | 56.5*4 | 66.5*4 | 79.5*4 | 98.5*4 | 116*4 | 140*4 | 157*4 | 166*4 | 184*4 | |
Yanayin farawa | Y-△ | |||||||||||
Ikon iko | ) | 0-25-50-75-100 | ||||||||||
Evaporator | Nau'in | Shell da tube | ||||||||||
Ƙarar ruwan sanyi | m³/h | 158 | 182.4 | 198.8 | 249.6 | 324 | 382.8 | 462.8 | 508 | 542.8 | 612 | |
Matsalolin ruwa | kPa | 46 | 43 | 45 | 45 | 48 | 43 | 45 | 42 | 45 | 46 | |
Haɗin bututu | inci | 8*2 | 8*2 | 10*2 | 10*2 | 10*2 | 10*2 | 12*2 | 12*2 | 8*4 | 8*4 | |
Condenser | Nau'in | Shell da tube | ||||||||||
Ruwan sanyaya ruwa | m³/h | 196.8 | 224 | 246.8 | 308 | 404 | 476 | 580 | 636 | 680 | 764 | |
Matsalolin ruwa | kPa | 42 | 45 | 48 | 46 | 48 | 45 | 42 | 48 | 48 | 48 | |
Haɗin bututu | inci | 6*2 | 6*2 | 8*2 | 8*2 | 8*2 | 4*4 | 4*4 | 6*4 | 6*4 | 6*4 | |
Na'urorin tsaro | Kariyar ciki ta kwampreso, akan kariya ta yanzu, babban kariya / ƙarancin matsa lamba, kan kariyar zafin jiki, kariyar ƙimar kwarara, tsarin lokaci/ɓataccen kariya, ƙarancin yanayin sanyaya, kariya ta daskarewa, kariyar daskarewa. | |||||||||||
Girma | Tsawon | mm | 3150 | 3480 | 3480 | 3650 | 3750 | 3750 | 4230 | 4350 | 4350 | 4420 |
Nisa | mm | 1700 | 1750 | 1790 | 2240 | 2600 | 2900 | 2960 | 2900 | 3300 | 3300 | |
Tsayi | mm | 1750 | 1850 | 1850 | 1950 | 2100 | 2150 | 2250 | 2250 | 2300 | 2450 | |
Cikakken nauyi | kg | 2650 | 2800 | 3450 | 3950 | 4450 | 4700 | 5250 | 5500 | 5750 | 6000 | |
Gudun nauyi | kg | 3200 | 3380 | 4160 | 4760 | 5270 | 5460 | 6100 | 6400 | 6680 | 6970 | |
Ƙididdigar da ke sama sun dogara da yanayin ƙira masu zuwa:
Mun tanadi haƙƙin gyara ƙayyadaddun bayanai ba tare da ƙarin sanarwa ba. |
Q1: Za ku iya taimaka mana mu ba da shawarar samfurin don aikinmu?
A1: Ee, muna da injiniya don bincika cikakkun bayanai kuma zaɓi samfurin da ya dace a gare ku.Bisa ga abubuwa masu zuwa:
1) Ƙarfin sanyi;
2) Idan baku sani ba, zaku iya ba da ƙimar kwarara zuwa injin ku, zazzabi a ciki da zafin jiki daga ɓangaren amfani da ku;
3) Yanayin yanayi;
4) Nau'in refrigerant, R22, R407c ko wani, pls bayyana;
5) Wutar lantarki;
6) Masana'antar aikace-aikace;
7) Pump kwarara da buƙatun matsa lamba;
8) Duk wani buƙatu na musamman.
Q2: Yadda za a tabbatar da samfurin ku tare da inganci mai kyau?
A2: Duk samfuranmu tare da takardar shaidar CE kuma kamfaninmu Yana bin tsarin sarrafa ingancin ingancin ISO900.Muna amfani da shahararrun na'urorin haɗi na duniya, kamar DANFOSS, COPLAND, SANYO, BITZER, HANBELL compressors, kayan lantarki na Schneider, DANFOSS/EMERSON na'urorin firiji.
Za a gwada raka'o'in gaba ɗaya kafin kunshin kuma za'a bincika marufin a hankali.
Q3: Menene garanti?
A3: Garanti na shekara 1 don duk sassan;Duk rayuwa aiki kyauta!
Q4: Shin ku masana'anta ne?
A4: Ee, muna da fiye da shekaru 23 a cikin kasuwancin firiji na masana'antu.Kamfaninmu da ke Shenzhen;Barka da zuwa ziyarci mu a kowane lokaci.Hakanan yana da haƙƙin mallaka akan ƙirar chillers.
Q5: Ta yaya zan iya yin oda?
A5: Send us enquiry via email: sales@szhero-tech.com, call us via Cel number +86 15920056387 directly.