Mai canzawa-gudun Screw chiller

Takaitaccen Bayani:

Maɓalli Maɓalli l Yanayin zafin ruwa 5C zuwa 20C.l DANFOSS inverter l Bitzer/Hanbell Semi-hermetic dunƙule kwampreso.l Energy ceton har zuwa 30% l Zazzabi daidaito har zuwa +/- 0.1C l Stepless iya aiki iko, l Shell da tube evaporator, babban inganci da kuma tsabtace l Harsashi da tube condenser tare da isasshen zafi musayar surface.l Bawul ɗin solenoid na firiji, don kare kwampreso lokacin da aka tsaya.l Gilashin gani na firiji, don ƙara saka idanu akan yanayin sanyi l Refrigerant Low da ...


Cikakken Bayani

Cikakkun bayanai

shiryawa da sufuri

takardar shaida

faq

Mabuɗin Siffofin

l Ruwan zafin jiki daga 5C zuwa 20C.

l DANFOSS inverter

l Bitzer/Hanbell Semi-hermetic dunƙule kwampreso.

l tanadin makamashi har zuwa 30%

l Daidaitaccen zafin jiki har zuwa +/- 0.1C

l Gudanar da iya aiki mara ƙarfi,

l Shell da tube evaporator, babban inganci da tsaftacewa

l Shell da na'urar bututu tare da isasshen yanayin musayar zafi.

l Bawul ɗin solenoid na firiji, don kare kwampreso lokacin da aka tsaya.

l Gilashin gani na firiji, don ƙara saka idanu akan yanayin firiji

l Refrigerant Low and high Matsi Gauges

l PLC iko, gaba ɗaya saka idanu na matsayi na gudana na naúrar.

l Motar fan Axial, tare da madaidaicin goyan bayan motar.

l Multi-kariya na'urorin don tabbatar da chiller da kayan aiki a guje aminci.

l Schneider kayan lantarki.

l Danfoss/Emerson abubuwan zafi.

 

Kariyar Tsaron Sashen

u Compressor na ciki kariya

u Sama da kariya ta yanzu

u High / low matsa lamba kariya

u Ƙararrawar zafin jiki mai girma

u Kariyar yawan zafin jiki

u Flow switch

u Tsarin lokaci/ɓataccen kariya

u Kariyar daskarewa

 

Babban tsari don HTSV-A, HTSV-W

Abu

Alamar

Nau'in

Wurin asali

Motoci

Compressor

Bitzer

Semi-hermetic dunƙule

Jamus

Compressor don zaɓi

Hanbell

Semi-hermetic dunƙule

Taiwan, China

Abubuwan thermal

Ma'aunin matsi

Jever

Nau'in mai

Taiwan, China

Mai sarrafa matsi

Fengsen

--

Taiwan, China

Bawul ɗin fadadawa

Emerson

Bawul faɗaɗa thermal

Amurka

Solenoid bawul

FDF/Emerson

--

China/Amurka

Gilashin gani

Danfoss

--

Denmark

Dry tace

Emerson/ALCO

--

Amurka

Bangaren musayar zafi

Condenser

Jarumi-Tech

Shell da tube/

 Bututun jan ƙarfe na aluminum

China

Evaporator

Jarumi-Tech

Shell da tube

China

Sarrafa

Inverter

DANFOSS

DAMARK

Mai sarrafawa

PUNP

PLC

Taiwan

Aiki panel

PUNP

LCD

Taiwan

Inverter

Danfoss

Denmark

AC contactor

LG

--

Koriya

Relay na tsaka-tsaki

Omron

--

Japan

Thermal gudun ba da sanda

LG

--

Koriya

Tsarin da ke sama ya dogara ne akan daidaitaccen ƙira.Duk wata tambaya da fatan za a tuntuɓi Hero-Tech.

 

 


  • Na baya:
  • Na gaba:

  • Mai sanyaya iska tare da VFD--Inverter Chiller

    Single dunƙule kwampreso

    Yanayinl [HTSV-***]

    40A

    50A

    60A

    65A

    75A

    85A

    Ƙarfin sanyaya mara kyau@7C

    *103kcal/h

    54.8 ~ 91.8

    71-118.5

    79.6 ~ 133.3

    97-161.6

    105.8-177

    125.5-209

    kw

    63.8 ~ 106.7

    82.6 ~ 137.8

    92.6-155

    112.8-188

    123-205.6

    146-243

    Ƙarfin sanyaya mara kyau@10C

    *103kcal/h

    62-103.2

    80-133.3

    90-150

    110-182

    119 ~199

    141-236

    kw

    72-120

    93-155

    104.4-174

    127.4-212

    139-231.3

    164.3-274

    Ƙarfin sanyaya mara kyau@12C

    *103kcal/h

    67.1 ~ 111.5

    86-143.6

    96-161.6

    117.8-197

    129-215

    152.2-254

    kw

    78-129.6

    100-167

    112-188

    137-229

    150-250

    177-295.6

    Matsakaicin amfani da wutar lantarki

    kw

    38.8

    49.3

    55.1

    64.2

    72.2

    81

    Ƙarfitushe

    3PH 380V ~ 415V 50HZ (3PH 220V/380V/440V 60HZ)domin zabi)

    Mai firiji

    Nau'in

    R407C

    Caji

    kg

    28

    35

    42

    45.5

    52

    60

    Sarrafa

    Lantarkifadada bawul

    Compressor

    Nau'in

    Semi-hermetic dunƙule

    Ƙarfin mota

    kw

    22.6 ku36.4

    28 ~45.7

    31.6 ku50.3

    38.2 ~ 59.4

    41.9 ~ 65.8

    46.7-74.6

    Yanayin farawa

    Inverter

    Kewayon kuɗi

    HZ

    30-50/60

    Evaporator

    Nau'in

    Shell da tube (farantin zafi Exchanger)

    Sanyiƙarar ruwa

    m3/h

    12 ~18

    16 ~23.6

    18 ~25.7

    22-28

    23.8-34.4

    28-40.5

    sauke matsa lamba

    kPa

    32

    35

    38

    38

    42

    45

    Bututuhaɗi

    inch

    3

    3

    3

    3

    3

    3

    Condenser

    Nau'in

    babban inganci finned cooper tube+Babban girma & ƙaramar amoaxialfan

    Ƙarfin mota

    kw

    2.4

    3.6

    4.8

    4.8

    6.4

    6.4

    Ƙarar iska

    m3/h

    40000

    50000

    60000

    70000

    80000

    90000

    Na'urorin tsaro

    Kariyar ciki ta kwampreso, overload gudun ba da sanda, high da low matsa lamba canji,anti daskarewa, Kariyar kuskuren lokaci, fitar da ma'aunin zafi da sanyio gas, magudanar ruwa

    Girma

    Tsawon

    mm

    2180

    2350

    2650

    2850

    3310

    3630

    Nisa

    mm

    1800

    1800

    1800

    1800

    1800

    1800

    Tsayi

    mm

    2050

    2050

    2163

    2163

    2200

    2140

    Cikakken nauyi

    kg

    1300

    1600

    1900

    2150

    2350

    2550

    Gudun nauyi

    kg

    1450

    1750

    2100

    2350

    2550

    2800

    Single dunƙule kwampreso

    Yanayinl [HTSV-***]

    90A

    100A

    120A

    135A

    150A

    Ƙarfin sanyaya mara kyau

    *103kcal/h

    149-249

    163.4 ku150

    193-321

    228-380

    241-444

    kw

    173.7-289.5

    189.9 ~ 316.5

    224-373.4

    265.1 ~ 441.8

    280-466.5

    Matsakaicin amfani da wutar lantarki

    kw

    83.1

    87.5

    114.3

    129

    141.5

    Ƙarfitushe

    3PH 380V ~ 415V 50HZ (3PH 220V/380V/440V 60HZ)domin zabi)

    Mai firiji

    Nau'in

    R407C

    Caji

    kg

    63

    70

    84

    94.5

    105

    Sarrafa

    Lantarkifadada bawul

    Compressor

    Nau'in

    Semi-hermetic dunƙule

    Ƙarfin mota

    kw

    49.1 ~ 76.7

    54.5 ~ 80.3

    65.3 ~ 103.5

    75.7-118.2

    79.9-126.7

    Yanayin farawa

    Inverter

    Kewayon kuɗi

    HZ

    30-50/60

    Evaporator

    Nau'in

    Shell da tube (farantin zafi Exchanger)

    Sanyiƙarar ruwa

    m3/h

    29-44

    32 ~ 46.4

    35-55

    45-62

    48-69.5

    Ruwasauke matsa lamba

    kPa

    43

    43

    41

    42

    41

    Bututuhaɗi

    inch

    3

    4

    4

    4

    5

    Condenser

    Nau'in

    babban inganci finned cooper tube+Babban girma & ƙaramar amoaxialfan

    Ƙarfin mota

    kw

    6.4

    7.2

    10.8

    10.8

    10.8

    Ƙarar iska

    m3/h

    90000

    100000

    135000

    1350000

    1500000

    Na'urorin tsaro

    Kariyar ciki ta kwampreso, overload gudun ba da sanda, high da low matsa lamba canji,anti daskarewa, Kariyar kuskuren lokaci, fitar da ma'aunin zafi da sanyio gas, magudanar ruwa

    Girma

    Tsawon

    mm

    3630

    4100

    5030

    5480

    5800

    Nisa

    mm

    1800

    2000

    2000

    2000

    2000

    Tsayi

    mm

    2140

    2210

    2160

    2210

    2210

    Cikakken nauyi

    kg

    2650

    2800

    2950

    3100

    3200

    Gudun nauyi

    kg

    2900

    3050

    3250

    3400

    3500

    Dual compressors

    Yanayinl [HTSV-***]

    80 AD

    100 AD

    120 AD

    130 AD

    150 AD

    170 AD

    Ƙarfin sanyaya mara kyau

    *103kcal/h

    129-222

    160-266.6

    180-299

    219-364

    239-399

    283-471

    kw

    144-259.2

    186-310

    208.8-348

    254.8 ~ 423.6

    278-462.6

    328.6 ~ 547.8

    Matsakaicin amfani da wutar lantarki

    kw

    79.2

    98.6

    112

    129.6

    142.4

    162

    Ƙarfitushe

    3PH 380V ~ 415V 50HZ (3PH 220V/380V/440V 60HZ)domin zabi)

    Mai firiji

    Nau'in

    R407C

    Caji

    kg

    28*2

    35*2

    42*2

    45.5*2

    52*2

    60*2

    Sarrafa

    Lantarkifadada bawul

    Compressor

    Nau'in

    Semi-hermetic dunƙule

    Ƙarfin mota

    kw

    45.2 ~ 72.8

    56-91.4

    63.2 ~ 100.6

    76.4 ~ 118.8

    83.8-131.6

    93.4-149.2

    Yanayin farawa

    Inverter

    Kewayon kuɗi

    HZ

    30-50/60

    Evaporator

    Nau'in

    Shell da tube (farantin zafi Exchanger)

    Sanyiƙarar ruwa

    m3/h

    24-35.6

    32 ~ 46.8

    36-50.8

    44-56

    47.6-68

    56-80

    sauke matsa lamba

    kPa

    45

    43

    43

    41

    41

    42

    Bututuhaɗi

    inch

    3

    4

    4

    5

    5

    6

    Condenser

    Nau'in

    babban inganci finned cooper tube+Babban girma & ƙaramar amoaxialfan

    Ƙarfin mota

    kw

    6.4

    7.2

    10.8

    10.8

    10.8

    12.8

    Ƙarar iska

    m3/h

    80000

    100000

    120000

    130000

    150000

    165000

    Na'urorin tsaro

    Kariyar ciki ta kwampreso, overload gudun ba da sanda, high da low matsa lamba canji,anti daskarewa, Kariyar kuskuren lokaci, fitar da ma'aunin zafi da sanyio gas, magudanar ruwa

    Girma

    Tsawon

    mm

    3630

    4100

    5030

    5480

    5800

    3630*2

    Nisa

    mm

    1800

    2000

    2000

    2000

    2000

    1800

    Tsayi

    mm

    2140

    2210

    2160

    2210

    2210

    2140

    Cikakken nauyi

    kg

    2500

    2950

    3350

    3750

    4100

    4350

    Gudun nauyi

    kg

    2800

    3250

    3750

    4050

    4500

    4850

    Moduloli biyu

    Yanayinl [HTSV-***]

    180AD

    200AD

    240AD

    270 AD

    300 AD

    Ƙarfin sanyaya mara kyau

    *103kcal/h

    299-498

    327-544

    385-642

    456-760

    482-802

    kw

    347.4-579

    379.8-633

    448-746.8

    530-884

    560-933

    Matsakaicin amfani da wutar lantarki

    kw

    166.2

    188.4

    225

    254.4

    279.2

    Ƙarfitushe

    3PH 380V ~ 415V 50HZ (3PH 220V/380V/440V 60HZ)domin zabi)

    Mai firiji

    Nau'in

    R407C

    Caji

    kg

    63*2

    70*2

    84*2

    94.5*2

    105*2

    Sarrafa

    Lantarkifadada bawul

    Compressor

    Nau'in

    Semi-hermetic dunƙule

    Ƙarfin mota

    kw

    98.2 ~ 153.4

    109-172.4

    130.6-207

    151.4 ~ 236.4

    159.8-253.4

    Yanayin farawa

    Inverter

    Kewayon kuɗi

    HZ

    30-50/60

    Evaporator

    Nau'in

    Shell da tube (farantin zafi Exchanger)

    Sanyiƙarar ruwa

    m3/h

    58-88

    64-92.8

    70-110

    90-124

    96-139

    Ruwasauke matsa lamba

    kPa

    43

    43

    41

    42

    41

    Bututuhaɗi

    inch

    6

    6

    8

    8

    8

    Condenser

    Nau'in

    babban inganci finned cooper tube+Babban girma & ƙaramar amoaxialfan

    Ƙarfin mota

    kw

    12.8

    16

    18

    18

    25.6

    Ƙarar iska

    m3/h

    180000

    200000

    260000

    2600000

    3000000

    Na'urorin tsaro

    Kariyar ciki ta kwampreso, overload gudun ba da sanda, high da low matsa lamba canji,anti daskarewa, Kariyar kuskuren lokaci, fitar da ma'aunin zafi da sanyio gas, magudanar ruwa

    Girma

    Tsawon

    mm

    3630*2

    4100*2

    5030*2

    5480*2

    5800*2

    Nisa

    mm

    1800

    2000

    2000

    2000

    2000

    Tsayi

    mm

    2140

    2210

    2160

    2210

    2210

    Cikakken nauyi

    kg

    4550

    4750

    5200

    5500

    5700

    Gudun nauyi

    kg

    5050

    5250

    5800

    6000

    6300

    Abubuwan da ke sama sun dogara da yanayin ƙira masu zuwa:

    1. Ruwan da aka sanyaya/komawa zafin jiki 10°C/15°C

    2. Matsakaicin zafin jiki 45 ° C, zafi mai ƙafewa 5 ° C

    3. Ya kamata a yi amfani da Chiller a ƙarƙashin max 40C na yanayi

    4. R22 don zaɓi, da zarar yanayin zafi ya wuce 45C, R134A ya kamata a yi amfani da shi.

    Mun tanadi haƙƙin gyara ƙayyadaddun bayanai ba tare da ƙarin sanarwa ba.

     

    Shirya kaya

    takardar shaida

    Q1: Za ku iya taimaka mana mu ba da shawarar samfurin don aikinmu?
    A1: Ee, muna da injiniya don bincika cikakkun bayanai kuma zaɓi samfurin da ya dace a gare ku.Bisa ga abubuwa masu zuwa:
    1) Ƙarfin sanyi;
    2) Idan baku sani ba, zaku iya ba da ƙimar kwarara zuwa injin ku, zazzabi a ciki da zafin jiki daga ɓangaren amfani da ku;
    3) Yanayin yanayi;
    4) Nau'in refrigerant, R22, R407c ko wani, pls bayyana;
    5) Wutar lantarki;
    6) Masana'antar aikace-aikace;
    7) Pump kwarara da buƙatun matsa lamba;
    8) Duk wani buƙatu na musamman.

     

     

    Q2: Yadda za a tabbatar da samfurin ku tare da inganci mai kyau?
    A2: Duk samfuranmu tare da takardar shaidar CE kuma kamfaninmu Yana bin tsarin sarrafa ingancin ingancin ISO900.Muna amfani da shahararrun na'urorin haɗi na duniya, kamar DANFOSS, COPLAND, SANYO, BITZER, HANBELL compressors, kayan lantarki na Schneider, DANFOSS/EMERSON na'urorin firiji.
    Za a gwada raka'o'in gaba ɗaya kafin kunshin kuma za'a bincika marufin a hankali.

     

     

    Q3: Menene garanti?
    A3: Garanti na shekara 1 don duk sassan;Duk rayuwa aiki kyauta!

     

     

    Q4: Shin ku masana'anta ne?
    A4: Ee, muna da fiye da shekaru 23 a cikin kasuwancin firiji na masana'antu.Kamfaninmu da ke Shenzhen;Barka da zuwa ziyarci mu a kowane lokaci.Hakanan yana da haƙƙin mallaka akan ƙirar chillers.

     

     

    Q5: Ta yaya zan iya yin oda?
    A5: Send us enquiry via email: sales@szhero-tech.com, call us via Cel number +86 15920056387 directly.