Inkcazelo emfutshane:

Iimpawu eziphambili l Ubushushu bamanzi buphakathi kwe-5C ukuya kwi-20C.l DANFOSS inverter l Bitzer/Hanbell semi-hermetic screw compressor.l Ukonga amandla ukuya kuthi ga kwi-30% l Ukuchaneka kobushushu ukuya kuthi ga ku +/-0.1C l Ulawulo lwamandla olungena nyathelo, l Igobolondo kunye ne-evaporator ityhubhu, ukusebenza kakuhle okuphezulu kunye nokucocwa l I-Shell kunye ne-tube condenser enomgangatho owaneleyo wokutshintsha ubushushu.l Ivalve ye-solenoid efrijini, ukukhusela icompressor xa imisiwe.l Iglasi yokubona epholileyo, ukujonga ngakumbi imeko yefriji l Isibandisi esiPhantsi kwaye ...


Iinkcukacha zeMveliso

Iinkcukacha zeParameter

ukupakisha kunye nokuthutha

isatifikethi

FAQ

Ezona mpawu

l Ubushushu bamanzi buphakathi kwe-5C ukuya kwi-20C.

l DANFOSS inverter

l I-Bitzer/Hanbell semi-hermetic screw compressor.

l Ukonga amandla ukuya kuthi ga kwi-30%

l Ukuchaneka kobushushu bufike ku +/-0.1C

l Ulawulo lwamandla olungenanyathelo,

l I-Shell kunye ne-evaporator ye-tube, ukusebenza okuphezulu kunye nokucoceka

l Iqokobhe kunye ne-tube condenser enomgangatho owaneleyo wokutshintshisa ubushushu.

l Ivalve ye-solenoid efrijini, ukukhusela icompressor xa imisiwe.

l Iglasi yokubona epholileyo, ukujonga ngakumbi imeko yefriji

l Isikhenkcezisi esiPhantsi kunye neeGauji zoxinzelelo oluphezulu

l Ulawulo lwe-PLC, iliso elipheleleyo lemo yeyunithi eqhubayo.

l I-Axial fan motor, enesibiyeli senkxaso yemoto ezimeleyo.

l Izixhobo zokukhusela ezininzi zokuqinisekisa ukuba i-chiller kunye nezixhobo ziqhuba ukhuseleko.

l amacandelo ombane Schneider.

l Danfoss/Emerson amacandelo thermal.

 

UKhuseleko loKhuseleko lweYunithi

u Ukhuseleko lwangaphakathi lweCompressor

u Ukhuseleko lwangoku

u Ukhuseleko oluphezulu / oluphantsi loxinzelelo

u I-alamu yobushushu bokukhutshwa okuphezulu

u Ukhuseleko lobushushu ngaphezulu

u Flow switch

u Ulandelelwano lweSigaba / isigaba esilahlekileyo ukhuseleko

u Ukhuseleko lokuchasa umkhenkce

 

Ubumbeko olungundoqo lwe-HTSV-A, HTSV-W

Into

Uphawu

Uhlobo

Indawo yemvelaphi

Iimoto

Isicompressor

Bitzer

Isikrufu sesemi-hermetic

Jemani

Icompressor yokhetho

Hanbell

Isikrufu sesemi-hermetic

eTaiwan, eTshayina

Amacandelo e-thermal

Ekhupha ifuthe

Jever

Uhlobo lweoli

eTaiwan, eTshayina

Umlawuli woxinzelelo

Fengsen

—-

eTaiwan, eTshayina

Ivalve yokwandisa

Emerson

Ivalve yokwandisa iThermal

i-USA

Ivalve yeSolenoid

FDF/Emerson

—-

China/i-USA

Iglasi yokubona

Danfoss

—-

Dominikha

Isihluzo esomileyo

Emerson/ALCO

—-

i-USA

Ukutshintshana kobushushu

Icondenser

Iqhawe-Tech

Iqokobhe kunye ityhubhu/

 I-Aluminiyam efakwe ityhubhu yobhedu

eTshayina

Umphunga

Iqhawe-Tech

Iqokobhe kunye ityhubhu

eTshayina

Ulawulo

Inverter

DANFOSS

DEMARK

Umlawuli

I-PUNP

PLC

eTaiwan

Iphaneli yokusebenza

I-PUNP

LCD

eTaiwan

Inverter

Danfoss

Dominikha

Umnxibelelanisi we-AC

LG

—-

eKorea

Ugqithiso oluphakathi

uOmron

—-

Japhan

I-Thermal relay

LG

—-

eKorea

Ubumbeko olungentla lusekwe kuyilo olusemgangathweni.Nayiphi na imibuzo nceda uqhagamshelane neHero-Tech.

 

 


  • Ngaphambili:
  • Okulandelayo:

  • Air cooled screw chiller nge VFD--Inverter chiller

    Icompressor yesikrufu esinye

    Imowudil [HTSV-***]

    40A

    50A

    60A

    65A

    75A

    85A

    Umthamo wokupholisa oqhelekileyo@7C

    *103kcal/h

    54.8~91.8

    71~118.5

    79.6~133.3

    97~161.6

    105.8~177

    125.5~209

    kw

    63.8~106.7

    82.6~137.8

    92.6~155

    112.8~188

    123~205.6

    146-243

    Umthamo wokupholisa oqhelekileyo@10C

    *103kcal/h

    62~103.2

    80~133.3

    90~150

    110-182

    119~199

    141-236

    kw

    72-120

    93~155

    104.4~174

    127.4~212

    139~231.3

    164.3~274

    Umthamo wokupholisa oqhelekileyo@12C

    *103kcal/h

    67.1~111.5

    86~143.6

    96~161.6

    117.8-197

    129-215

    152.2~254

    kw

    78~129.6

    100~167

    112-188

    137-229

    150~250

    177~295.6

    Ukusetyenziswa kwamandla aphezulu

    kw

    38.8

    49.3

    55.1

    64.2

    72.2

    81

    Amandlaumthombo

    3PH 380V~415V 50HZ (3PH 220V/380V/440V 60HZngokhetho)

    Isikhenkcisi

    Uhlobo

    R407C

    Ukuhlawulisa

    kg

    28

    35

    42

    45.5

    52

    60

    Ulawulo

    Umbaneivalve yokwandisa

    Isicompressor

    Uhlobo

    Isikrufu sesemi-hermetic

    Amandla emoto

    kw

    22.6~36.4

    28~45.7

    31.6~50.3

    38.2~59.4

    41.9~65.8

    46.7~74.6

    Imowudi yokuqalisa

    Inverter

    Uluhlu lwemali

    HZ

    30~50/60

    Umphunga

    Uhlobo

    Iqokobhe kunye netyhubhu (ipleyiti yokutshintshisa ubushushu)

    Ndipholileumthamo wamanzi

    m3/h

    12 ~18

    16~23.6

    18~25.7

    22-28

    23.8~34.4

    28~40.5

    ukwehla koxinzelelo

    kPa

    32

    35

    38

    38

    42

    45

    Umbhobhouqhagamshelwano

    inch

    3

    3

    3

    3

    3

    3

    Icondenser

    Uhlobo

    ityhubhu ye-cooper esebenzayo ephezulu+Umthamo omkhulu kunye nengxolo ephantsiaxialfan

    Amandla emoto

    kw

    2.4

    3.6

    4.8

    4.8

    6.4

    6.4

    Umthamo womoya

    m3/h

    40000

    50000

    60000

    70000

    80000

    90000

    Izixhobo zokhuseleko

    Ukhuseleko lwangaphakathi lweCompressor, ukulayishwa okugqithisiweyo, ukutshintshela uxinzelelo oluphezulu noluphantsi,ukuchasa umkhenkce, ukhuseleko lwempazamo yesigaba, ukukhupha i-thermostat yegesi, i-flow switch

    Ubungakanani

    Ubude

    mm

    2180

    2350

    2650

    2850

    3310

    3630

    Ububanzi

    mm

    1800

    1800

    1800

    1800

    1800

    1800

    Ubude

    mm

    2050

    2050

    2163

    2163

    2200

    2140

    Ukusinda okushiyekile

    kg

    1300

    1600

    1900

    2150

    2350

    2550

    Ukubaleka ubunzima

    kg

    1450

    1750

    2100

    2350

    2550

    2800

    Icompressor yesikrufu esinye

    Imowudil [HTSV-***]

    90A

    100A

    120A

    135A

    150A

    Umthamo wokupholisa oqhelekileyo

    *103kcal/h

    149-249

    163.4~150

    193~321

    228~380

    241~444

    kw

    173.7~289.5

    189.9~316.5

    224~373.4

    265.1~441.8

    280~466.5

    Ukusetyenziswa kwamandla aphezulu

    kw

    83.1

    87.5

    114.3

    129

    141.5

    Amandlaumthombo

    3PH 380V~415V 50HZ (3PH 220V/380V/440V 60HZngokhetho)

    Isikhenkcisi

    Uhlobo

    R407C

    Ukuhlawulisa

    kg

    63

    70

    84

    94.5

    105

    Ulawulo

    Umbaneivalve yokwandisa

    Isicompressor

    Uhlobo

    Isikrufu sesemi-hermetic

    Amandla emoto

    kw

    49.1~76.7

    54.5~80.3

    65.3~103.5

    75.7~118.2

    79.9~126.7

    Imowudi yokuqalisa

    Inverter

    Uluhlu lwemali

    HZ

    30~50/60

    Umphunga

    Uhlobo

    Iqokobhe kunye netyhubhu (ipleyiti yokutshintshisa ubushushu)

    Ndipholileumthamo wamanzi

    m3/h

    29-44

    32~46.4

    35~55

    45~62

    48~69.5

    Amanziukwehla koxinzelelo

    kPa

    43

    43

    41

    42

    41

    Umbhobhouqhagamshelwano

    inch

    3

    4

    4

    4

    5

    Icondenser

    Uhlobo

    ityhubhu ye-cooper esebenzayo ephezulu+Umthamo omkhulu kunye nengxolo ephantsiaxialfan

    Amandla emoto

    kw

    6.4

    7.2

    10.8

    10.8

    10.8

    Umthamo womoya

    m3/h

    90000

    100000

    135000

    1350000

    1500000

    Izixhobo zokhuseleko

    Ukhuseleko lwangaphakathi lweCompressor, ukulayishwa okugqithisiweyo, ukutshintshela uxinzelelo oluphezulu noluphantsi,ukuchasa umkhenkce, ukhuseleko lwempazamo yesigaba, ukukhupha i-thermostat yegesi, i-flow switch

    Ubungakanani

    Ubude

    mm

    3630

    4100

    5030

    5480

    5800

    Ububanzi

    mm

    1800

    2000

    2000

    2000

    2000

    Ubude

    mm

    2140

    2210

    2160

    2210

    2210

    Ukusinda okushiyekile

    kg

    2650

    2800

    2950

    3100

    3200

    Ukubaleka ubunzima

    kg

    2900

    3050

    3250

    3400

    3500

    Iicompressors ezimbini

    Imowudil [HTSV-***]

    80AD

    100AD

    120AD

    130AD

    150AD

    170AD

    Umthamo wokupholisa oqhelekileyo

    *103kcal/h

    129-222

    160~266.6

    180-299

    219~364

    239-399

    283~471

    kw

    144~259.2

    186-310

    208.8~348

    254.8~423.6

    278~462.6

    328.6~547.8

    Ukusetyenziswa kwamandla aphezulu

    kw

    79.2

    98.6

    112

    129.6

    142.4

    162

    Amandlaumthombo

    3PH 380V~415V 50HZ (3PH 220V/380V/440V 60HZngokhetho)

    Isikhenkcisi

    Uhlobo

    R407C

    Ukuhlawulisa

    kg

    28*2

    35*2

    42*2

    45.5*2

    52*2

    60*2

    Ulawulo

    Umbaneivalve yokwandisa

    Isicompressor

    Uhlobo

    Isikrufu sesemi-hermetic

    Amandla emoto

    kw

    45.2~72.8

    56~91.4

    63.2~100.6

    76.4~118.8

    83.8~131.6

    93.4~149.2

    Imowudi yokuqalisa

    Inverter

    Uluhlu lwemali

    HZ

    30~50/60

    Umphunga

    Uhlobo

    Iqokobhe kunye netyhubhu (ipleyiti yokutshintshisa ubushushu)

    Ndipholileumthamo wamanzi

    m3/h

    24~35.6

    32~46.8

    36~50.8

    44~56

    47.6~68

    56~80

    ukwehla koxinzelelo

    kPa

    45

    43

    43

    41

    41

    42

    Umbhobhouqhagamshelwano

    inch

    3

    4

    4

    5

    5

    6

    Icondenser

    Uhlobo

    ityhubhu ye-cooper esebenzayo ephezulu+Umthamo omkhulu kunye nengxolo ephantsiaxialfan

    Amandla emoto

    kw

    6.4

    7.2

    10.8

    10.8

    10.8

    12.8

    Umthamo womoya

    m3/h

    80000

    100000

    120000

    130000

    150000

    165000

    Izixhobo zokhuseleko

    Ukhuseleko lwangaphakathi lweCompressor, ukulayishwa okugqithisiweyo, ukutshintshela uxinzelelo oluphezulu noluphantsi,ukuchasa umkhenkce, ukhuseleko lwempazamo yesigaba, ukukhupha i-thermostat yegesi, i-flow switch

    Ubungakanani

    Ubude

    mm

    3630

    4100

    5030

    5480

    5800

    3630*2

    Ububanzi

    mm

    1800

    2000

    2000

    2000

    2000

    1800

    Ubude

    mm

    2140

    2210

    2160

    2210

    2210

    2140

    Ukusinda okushiyekile

    kg

    2500

    2950

    3350

    3750

    4100

    4350

    Ukubaleka ubunzima

    kg

    2800

    3250

    3750

    4050

    4500

    4850

    Iimodyuli ezimbini

    Imowudil [HTSV-***]

    180AD

    200AD

    240AD

    270AD

    300AD

    Umthamo wokupholisa oqhelekileyo

    *103kcal/h

    299-498

    327~544

    385~642

    456~760

    482~802

    kw

    347.4~579

    379.8~633

    448~746.8

    530~884

    560~933

    Ukusetyenziswa kwamandla aphezulu

    kw

    166.2

    188.4

    225

    254.4

    279.2

    Amandlaumthombo

    3PH 380V~415V 50HZ (3PH 220V/380V/440V 60HZngokhetho)

    Isikhenkcisi

    Uhlobo

    R407C

    Ukuhlawulisa

    kg

    63*2

    70*2

    84*2

    94.5*2

    105*2

    Ulawulo

    Umbaneivalve yokwandisa

    Isicompressor

    Uhlobo

    Isikrufu sesemi-hermetic

    Amandla emoto

    kw

    98.2~153.4

    109~172.4

    130.6~207

    151.4~236.4

    159.8~253.4

    Imowudi yokuqalisa

    Inverter

    Uluhlu lwemali

    HZ

    30~50/60

    Umphunga

    Uhlobo

    Iqokobhe kunye netyhubhu (ipleyiti yokutshintshisa ubushushu)

    Ndipholileumthamo wamanzi

    m3/h

    58~88

    64~92.8

    70-110

    90~124

    96-139

    Amanziukwehla koxinzelelo

    kPa

    43

    43

    41

    42

    41

    Umbhobhouqhagamshelwano

    inch

    6

    6

    8

    8

    8

    Icondenser

    Uhlobo

    ityhubhu ye-cooper esebenzayo ephezulu+Umthamo omkhulu kunye nengxolo ephantsiaxialfan

    Amandla emoto

    kw

    12.8

    16

    18

    18

    25.6

    Umthamo womoya

    m3/h

    180000

    200000

    260000

    2600000

    3000000

    Izixhobo zokhuseleko

    Ukhuseleko lwangaphakathi lweCompressor, ukulayishwa okugqithisiweyo, ukutshintshela uxinzelelo oluphezulu noluphantsi,ukuchasa umkhenkce, ukhuseleko lwempazamo yesigaba, ukukhupha i-thermostat yegesi, i-flow switch

    Ubungakanani

    Ubude

    mm

    3630*2

    4100*2

    5030*2

    5480*2

    5800*2

    Ububanzi

    mm

    1800

    2000

    2000

    2000

    2000

    Ubude

    mm

    2140

    2210

    2160

    2210

    2210

    Ukusinda okushiyekile

    kg

    4550

    4750

    5200

    5500

    5700

    Ukubaleka ubunzima

    kg

    5050

    5250

    5800

    6000

    6300

    Ezi nkcukacha zingentla zihambelana nezi meko zoyilo zilandelayo:

    1. Unikezelo lwamanzi abandayo/iqondo lobushushu lokubuya 10°C/15°C

    2. Ubushushu bokunciphisa 45°C, ubushushu obuphumayo bungu-5°C

    3. I-Chiller kufuneka isetyenziswe phantsi kobushushu obuphezulu be-40C kwindawo

    4. I-R22 yokuzikhethela, xa ubushushu be-ambient bungaphezu kwe-45C, kufuneka kusetyenziswe i-R134A.

    Sinelungelo lokuguqula iinkcukacha ngaphandle kwesaziso esongezelelweyo.

     

    Ukupakisha ukuthunyelwa

    isatifikethi

    Q1: Ngaba ungasinceda ukuba sicebise imodeli yeprojekthi yethu?
    A1: Ewe, sineenjineli ukujonga iinkcukacha kwaye sikukhethele imodeli echanekileyo.Ngokusekelwe koku kulandelayo:
    1) Umthamo wokupholisa;
    2) Ukuba awuyazi, unganikezela ngesantya sokuhamba kumatshini wakho, ubushushu ngaphakathi kunye nobushushu obuphuma kwindawo oyisebenzisayo;
    3) Ubushushu bendalo;
    4) Uhlobo lwefriji, i-R22, i-R407c okanye enye, pls cacisa;
    5) Umbane;
    6) Ushishino lwezicelo;
    7) Ukuhamba kwempompo kunye neemfuno zoxinzelelo;
    8) Naziphi na ezinye iimfuno ezikhethekileyo.

     

     

    Q2: Uyiqinisekisa njani imveliso yakho ngomgangatho olungileyo?
    A2: Zonke iimveliso zethu ezinesatifikethi se-CE kunye nenkampani yethu ithobela ngokungqongqo inkqubo yolawulo lwe-ISO900.Sisebenzisa izixhobo zohlobo oludumileyo kwihlabathi liphela, ezinje ngeDANFOSS, iCOPELAND, SANYO, BITZER, HANBELL compressors, izinto zombane zeSchneider, iDANFOSS/EMERSON izinto zefriji.
    Iiyunithi ziya kuvavanywa ngokupheleleyo phambi kwephakheji kwaye ukupakishwa kuya kuhlolwa ngononophelo.

     

     

    Q3: Yintoni iwaranti?
    I-A3: Iwaranti yonyaka we-1 kuwo onke amalungu;Ubomi bonke busebenza mahala!

     

     

    I-Q4: Ngaba ungumenzi?
    I-A4: Ewe, sineminyaka engaphezu kwama-23 kwishishini lefriji yefriji.Umzi-mveliso wethu oseShenzhen;Wamkelekile ukusindwendwela nangaliphi na ixesha.Kwakhona ube ne-patent kwi-design ye-chillers.

     

     

    I-Q5: Ndingayifaka njani iodolo?
    A5: Send us enquiry via email: sales@szhero-tech.com, call us via Cel number +86 15920056387 directly.