Sida loo doorto Bambada ugu habboon

2BAR BAMB

Bamka biyaha la qaboojiyey:

Qalab u kaxeeya biyaha si ay ugu wareegaan wareegga biyaha qabow.Sida aan ognahay, dhamaadka qolka qaboojiyaha (sida gariiradda marawaxada, qaybta daawaynta hawada, iwm.) waxay u baahan yihiin biyaha qabow ee ay bixiso qaboojiyaha, laakiin biyaha la qaboojiyey si dabiici ah uma qulquli doonaan sababtoo ah xaddidaadda caabbinta, taas oo u baahan. bamka si uu u wado biyaha la qaboojiyey si uu u wareego si loo gaaro ujeedada wareejinta kulaylka.

 

Bamka qaboojinta:

Qalab u kaxeeya biyaha si ay ugu wareegaan wareegga biyaha qaboojinta.Sida aan ognahay, biyaha qaboojinta waxay ka qaadaan xoogaa kulayl qaboojiyaha ka dib markay galaan qaboojiyaha, ka dibna waxay u qulqulaan munaaradda qaboojinta si ay u sii daayaan kulaylkan.Matoorka biyaha qaboojinta ayaa mas'uul ka ah wadista biyaha qaboojinta si ay ugu wareegaan wareegga xiran ee u dhexeeya cutubka iyo munaaradda qaboojinta.Qaabku wuxuu la mid yahay bamka biyaha la qaboojiyey.

jaantuska habka biyaha

Bamka biyaha keena:

Qalabka qaboojinta biyaha dib-u-buuxinta, mas'uul ka ah daaweynta biyaha jilicsan ee nidaamka.Qaabku wuxuu la mid yahay bamka biyaha sare.Matoorada sida caadiga ah loo isticmaalo waa bamka dhexe ee jiifka ah iyo bamka dhexe ee toosan, kaas oo loo isticmaali karo nidaamka biyaha qaboojiyay, nidaamka biyaha qaboojinta iyo nidaamka buuxinta biyaha.Bamka centrifugal ee toosan waxa loo isticmaali karaa aagga qolka weyn, iyo bamka centrifugal ee toosan waxa loo tixgelin karaa aagga qolka yar.

 

Hordhac qaabka bamka biyaha, tusaale ahaan, 250RK480-30-W2

250: dhexroorka godka 250 (mm);

RK: kululaynta iyo qaboojiyaha wareegga wareegga;

480: dhibic socodka naqshadeynta 480m3 / h;

30: barta madaxa naqshadeynta 30m;

W2: Nooca dhejinta bamka.

 

Hawlaha isbarbar socda ee matoorada biyaha:

Tirada bambooyin

socodka

Qiimaha lagu daray socodka

Hoosudhaca socodka marka la barbar dhigo hawlgalinta hal bamka

1

100

/

 

2

190

90

5%

3

251

61

16%

4

284

33

29%

5

300

16

40%

Sida laga arki karo shaxda kore: marka bamka biyuhu uu si isbarbar socda u socdo, heerka qulqulka ayaa xoogaa yara yaraada;Marka tirada saldhigyada isbarbar-dhigga ahi ay ka bataan 3, dhimashadu si gaar ah ayay u daran tahay.

 

Waxaa lagu talinayaa in:

1, xulashada bambooyin badan, si ay u tixgeliyaan attenuation ee socodka, guud ahaan dheeraad ah 5% ~ 10% margin.

2. Bamka biyuhu waa in aanu ka badnayn 3 qaybood oo is barbar socda, taas oo ah, waa in aanu ka badnayn 3 qaybood marka la doorto qaboojiyaha qaboojiyaha.

3, waa in la sameeyaa mashruucyo waaweyn iyo kuwo dhexdhexaad ah oo isugu jira kuwo qabow iyo kuwo kulul

 

Guud ahaan, tirada bambooyinka biyaha la qaboojiyey iyo matoorada biyaha qaboojinta waa inay u dhigmaan tirada qaboojiyaha, midna waa in loo isticmaalaa sidii kayd.Bamka biyaha waxaa guud ahaan lagu doortaa iyadoo la raacayo mabda'a hal isticmaal iyo hal kayd si loo hubiyo sahayda biyaha lagu kalsoonaan karo ee nidaamka.

Magacyada bambooyinka waxaa guud ahaan lagu calaamadeeyay cabbirro sida socodka la qiimeeyay iyo madaxa (eeg magaca bamka).Marka aan doorano bamka, waxaan u baahanahay inaan marka hore go'aamino socodka iyo madaxa bamka, ka dibna go'aamin bamka u dhigma iyadoo loo eegayo shuruudaha rakibaadda iyo xaaladda goobta.

 

(1) Habka xisaabinta socodka ee bamka biyaha la qaboojiyey iyo bamka biyaha qaboojinta:

L (m3/h) =Q(Kw)×(1.15~1.2)/(5℃×1.163)

Q- Awoodda qaboojinta ee martida loo yahay, Kw;

L- Socodka bamka biyaha qaboojinta, m3/saacaddii.

 

(2) Socodka bamka sahayda:

Mugga biyaha ee caadiga ah waa 1% ~ 2% ee mugga biyaha wareega ee nidaamka.Si kastaba ha ahaatee, marka la dooranayo bamka sahayda, socodka bamka sahayda waa in uusan la kulmin oo kaliya heerka caadiga ah ee ku-celinta biyaha ee nidaamka biyaha ee kor ku xusan, laakiin sidoo kale tixgeli kordhinta mugga biyaha ee kor u kaca haddii ay dhacdo shil.Sidaa darteed, socodka bamka sahayda ayaa inta badan aan ka yarayn 4 jeer mugga biyaha dib-u-celinta caadiga ah.

Mugga waxtarka leh ee haanta sahayda biyaha waxaa loo tixgelin karaa iyadoo loo eegayo biyaha caadiga ah ee 1 ~ 1.5h.

 

(3) Halabuurka madaxa bamka biyaha la qaboojiyey:

Iska caabbinta biyaha ee uumiga ee unugga qaboojiyaha: guud ahaan 5 ~ 7mH2O;(Faahfaahin ka eeg muunadda alaabta)

Qalabka dhamaadka (cutubka hawo-mareenka, gariiradda marawaxada, iwm.) qaboojiyaha miiska ama caabbinta biyaha ee uumiga: guud ahaan 5 ~ 7mH2O;(Fadlan tixraac muunadda alaabta qiimayaal gaar ah)

 

Iska caabbinta filtarka dambe ee biyaha, laba-jid oo nidaaminaya waalka, iwm, guud ahaan waa 3 ~ 5mH2O;

Kala-soocida biyaha, caabbinta biyaha ururiyaha: guud ahaan 3mH2O;

Nidaamka qaboojinta tuubooyinka biyaha oo ay weheliyaan iska caabbinta iyo luminta iska caabinta maxalliga ah: guud ahaan 7 ~ 10mH2O;

Marka la soo koobo, madaxa bamka biyaha la qaboojiyey waa 26 ~ 35mH2O, guud ahaan 32 ~ 36mH2O.

Fiiro gaar ah: xisaabinta madaxa waa in lagu saleeyaa xaaladda gaarka ah ee nidaamka qaboojiyaha, ma koobi karo qiimaha khibradda!

 

(4) Halabuurka madaxa bamka qaboojinta:

Cabbitaanka biyaha qaboojiyaha ee unugga qaboojiyaha: guud ahaan 5 ~ 7mH2O;(Fadlan tixraac muunadda alaabta qiimayaal gaar ah)

Cadaadiska buufin: guud ahaan 2 ~ 3mH2O;

Farqiga dhererka ee u dhexeeya saxaarada biyaha iyo biibiile ee munaaradda qaboojinta ( munaaradda qaboojinta furan): guud ahaan 2 ~ 3mH2O;

 

Iska caabbinta filtarka dambe ee biyaha, laba-jid oo nidaaminaya waalka, iwm, guud ahaan waa 3 ~ 5mH2O;

Nidaamka qaboojinta tuubooyinka biyaha oo ay weheliyaan iska caabbinta iyo luminta iska caabinta maxalliga ah: guud ahaan 5 ~ 8mH2O;

Marka la soo koobo, madaxa bamka qaboojinta waa 17 ~ 26mH2O, guud ahaan 21 ~ 25mH2O.

 

(5) madaxa bamka quudinta:

Madaxu waa madaxa hodanka ah ee masaafada u dhaxaysa barta cadaadiska joogtada ah iyo barta ugu sareysa + caabbinta dhamaadka nuugista iyo dhamaadka bamka +3 ~ 5mH2O.


Waqtiga post: Dec-03-2022
  • Hore: