Hero-Tech chiller endistriyèl

  • IMG_20190521_094950

    Chiller endistriyèl ki refwadi lè

    0.5ton a 100ton refwadisman kapasite

    3ph 380v/50hz, 220v/380v/440v 60hz pou opsyon

    SANYO/DANFOSS/COPELAND/BITZER COMPRESSOR

    Ranje tanperati dlo a: -35C pou 35C

    Estabilite tanperati: +/-1C pou 2C

    Kondisyon travay:-25C a 45C tanperati anbyen

    Konpozan elektrik Schneider

    R22/R407c/R410A kòm estanda,

    Pati refrijerasyon Emerson/Danfoss

    Kontwolè mikro

    Air refwadi Deep V konsepsyon aliminyòm finned kondansateur tib kwiv

    Ti bri, enstalasyon fasil ak operasyon

    Tan livrezon kout:

    0.5hp a 30hp nan stock

    40hp a 50hp nan 15 jou

    60hp a 100hp nan 25 jou

    Konsepsyon chiller Customized

    OEM sèvis

  • Dlo refwadi endistriyèl chiller

    3ton a 100ton refwadisman kapasite

    3ph 380v/50hz, 220v/380v/440v 60hz pou opsyon

    SANYO/DANFOSS/COPELAND/BITZER COMPRESSOR

    Ranje tanperati dlo: -35C a 35C

    Estabilite tanperati: +/-1C pou 2C

    Kondisyon travay: -25C a 45C tanperati anbyen

    Konpozan elektrik Schneider

    R22/R407C kòm estanda, R410A ak R134a pou opsyon

    Pati refrijerasyon Emerson/Danfoss

    Kontwolè mikro

    Segondè efikasite koki ak kondansasyon tib

    Tan livrezon kout:

    3hp a 30hp nan stock

    40hp a 100hp nan 25 jou

    Konsepsyon chiller Customized

    OEM sèvis

  • Air refwadi vis chiller

    30ton a 500ton refwadisman kapasite

    3HP 380-415V/50hz, 220V/380V/440V 60hz pou opsyon

    HANBELL / BITZER vis COMPRESSOR

    3/4 etap kontwòl kapasite: 33% -66% -100%; 25% -50% -75% -100%

    Ranje tanperati dlo: -30C a 35C

    Estabilite tanperati: +/-1C pou 2C

    Kondisyon travay: -25C a 40C tanperati anbyen

    Konpozan elektrik Schneider

    R22/R407c kòm estanda, R134a pou opsyon

    Pati refrijerasyon Emerson/Danfoss

    SIEMENS PLC kontwolè

    Weinview panèl operasyon manyen ekran

    Air refwadi Deep V konsepsyon aliminyòm finned kondansateur tib kwiv

    Ti bri, enstalasyon fasil ak operasyon, lavi sèvis long

    Tan livrezon kout:

    0.5hp a 30hp nan stock;

    40hp a 50hp nan 15 jou

    60hp a 100hp nan 25 jou

    Konsepsyon chiller Customized

    OEM sèvis

  • Dlo refwadi vis chiller

    30ton a 1000ton refwadisman kapasite

    3HP 380-415V/50hz, 220V/380V/440V 60hz pou opsyon

    HANBELL / BITZER vis COMPRESSOR

    3/4 etap kontwòl kapasite: 33% -66% -100%; 25% -50% -75% -100%

    Ranje tanperati dlo: -30C a 35C

    Estabilite tanperati: +/-1C pou 2C

    Kondisyon travay: -25C a 40C tanperati anbyen

    Konpozan elektrik Schneider

    R22/R407c kòm estanda, R134a pou opsyon

    Pati refrijerasyon Emerson/Danfoss

    SIEMENS PLC kontwolè

    Weinview panèl operasyon manyen ekran

    Evaporateur/Kondansasyon: Koki ak tib efikasite segondè

    Ti bri, enstalasyon fasil ak operasyon, lavi sèvis long

    Tan livrezon kout:

    0.5hp a 30hp nan stock

    40hp a 50hp nan 15 jou

    60hp a 100hp nan 25 jou

    Konsepsyon chiller Customized

    OEM sèvis

  • Chiller lè refwadi ba tanperati

    Mete Tanperati: -35C a 5C

    3ph 380v/50hz, 220v/380v/440v 60hz pou opsyon

    SANYO/DANFOSS/COPELAND/BITZER/HANBELL compresseurs pou opsyon

    Ranje tanperati anbyen travay: -25C a 40C

    Estabilite tanperati: +/-1C pou 2C

    Konpozan elektrik Schneider

    R22/R407c/R404A/R410A/R134A pou opsyon

    Pati refrijerasyon Emerson/Danfoss

    Kontwolè mikro

    Siemens PLC kontwolè

    Air refwadi Deep V konsepsyon aliminyòm finned kondansateur tib kwiv

    Ti bri, enstalasyon fasil ak operasyon

    OEM & ODM sèvis yo ofri

  • Dlo refwadi tanperati ki ba chiller

    Mete Tanperati: -35C a 5C

    3ph 380v/50hz, 220v/380v/440v 60hz pou opsyon

    SANYO/DANFOSS/COPELAND/BITZER/HANBELL compresseurs pou opsyon

    Ranje tanperati anbyen travay: -25C a 45C

    Estabilite tanperati: +/-1C pou 2C

    Konpozan elektrik Schneider

    R22/R407c/R404A/R410A/R134A pou opsyon

    Pati refrijerasyon Emerson/Danfoss

    Kontwolè mikro

    Siemens PLC kontwolè

    Segondè efikasite koki ak kondansasyon tib

    OEM & ODM sèvis yo ofri

  • Air refwadi eksplozyon prèv chiller --- 3ton a 500tonDlo refwadi eksplozyon prèv chiller --- 3ton a 1000ton

    3HP 380-415V/50hz, 220V/380V/440V 60hz pou opsyon

    SANYO/DANFOSS/COPELAND/BITZER/HANBELL compresseurs pou opsyon

    3/4 etap kontwòl kapasite: 33% -66% -100%; 25% -50% -75% -100%

    Ranje tanperati dlo: -30C a 35C

    Estabilite tanperati: +/-1C pou 2C

    Kondisyon travay: -25C a 40C tanperati anbyen

    Konpozan elektrik Schneider

    R22/R407c/R404A/R410A/R134A pou opsyon

    Pati refrijerasyon Emerson/Danfoss

    Kontwòl mikrokopitè

    SIEMENS PLC kontwolè pou chiller kalite vis

    Weinview manyen ekran operasyon panèl pou chiller vis

    Air refwadi Deep V konsepsyon aliminyòm finned kondansateur tib kwiv

    Dlo refwadi koki ak kondansasyon tib

    Ti bri, enstalasyon fasil ak operasyon, lavi sèvis long

    Konsepsyon chiller Customized apwovizyone

  • Chiller vis ki inonde

    Ranje tanperati rezèv dlo: 5C a 20C

    Ekipman pou pouvwa: 380V 50HZ 3PH;220V/380V/440V/460V 60HZ pou opsyon

    Kapasite refwadisman: 100ton a 1000ton

    Vis kalite compresseurs

    Evaporator: segondè efikas inonde evaporator

    Kondansasyon koki ak tib

    Siemens PLC kontwolè

    Segondè efikasite: 20% pi wo pase dlo refwadi vis chiller

    Aplikasyon:

  • Inite chiller kondansateur evaporatif

    Ekipman pou pouvwa: 380V 50HZ 3PH;220V/380V/440V/460V 60HZ pou opsyon

    Kapasite refwadisman: 60ton a 1000ton

    Vis oswa woulo liv kalite compresseurs

    Shell ak tib evaporator

    Kondansasyon evaporatif

    Axial fanatik pou kondansasyon

    Ekonomize enèji: ekonomize enèji pase tou de dlo refwadi ak gwo kay won refwadisman nòmal ak lè refwadi vis chiller

    Segondè efikasite: Konpare ak lè refwadi vis chiller, COP nan chiller kondansateur evaporasyon pi wo pase sa ki nan chiller natirèl lè-refwadi.

  • Chofaj ak refwadisman chiller

    7C-35C dlo frèt

    35C-90C dlo cho

    Hermetic woulo liv COMPRESSOR

    R407C R410A R134A R22 pou opsyon

    Pouvwa chofaj pou opsyon: 6kw 9kw 12kw 18kw 24kw

  • Mayetik lwil oliv gratis santrifujeur chiller

    Inite ki refwadi dlo

    Aplikasyon: èkondisyone santral oswa pwosesis endistriyèl

    Ekipman pou pouvwa: 380V 50HZ 3PH

    Kapasite refwadisman: 60ton a 1800ton

    Santrifij COMPRESSOR ak levitasyon mayetik

    Evaporatè ki inonde

    Efikasite inegalabl: 60% pi wo pase ak woulo liv ak vis compresseurs

    Operasyon ekstrèmman an silans

    Ba nan aktyèl prese

  • Chiller lazè

    0.2Ton a 15Ton

    Hermetic Rotary oswa Scroll COMPRESSOR

    R407C R410A R134A R22 pou opsyon

    Evaporatè: SS Plak oswa tank SS ak bobin SS

    R407C R410A R134A R22 pou opsyon